1.
Opt Express ; 18(17): 18394-400, 2010 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-20721233

RESUMO

A white-light source operated polymer-based micromachined Fabry-Perot biochemical sensor is reported. As a refractive-index sensitive optical sensor, its transducing signal varies upon the changes of the effective refractive index in the Fabry-Perot cavity. This sensor is fabricated from PDMS and glass. More specifically, this sensor is a micromachined Fabry-Perot interferometer (microFPI) and is fabricated by bonding a glass substrate and the soft-lithographically patterned PDMS. Several biochemicals have been detected with the microFPI biochemical sensors. Measurements show that rabbit IgG at a concentration of as low as 5 to 50 ng/ml can be detected even without any performance optimization of the devices.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Dimetilpolisiloxanos/química , Interferometria/métodos , Microtecnologia/métodos , Nylons/química , Animais , Anticorpos Imobilizados/química , Desenho de Equipamento , Vidro/química , Imunoglobulina G/química , Interferometria/instrumentação , Microtecnologia/instrumentação , Modelos Teóricos , Coelhos
2.
Heliyon ; 2(2): e00072, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27441251

RESUMO

A major factor contributing to the failure of orthopedic and orthodontic implants is post-surgical infection. Coating metallic implant surfaces with anti-microbial agents has shown promise but does not always prevent the formation of bacterial biofilms. Furthermore, breakdown of these coatings within the human body can cause release of the anti-microbial drugs in an uncontrolled or unpredictable fashion. In this study, we used a calcium alginate and calcium phosphate cement (CPC) hydrogel composite as the base material and enriched these hydrogels with the anti-microbial drug, gentamicin sulfate, loaded within a halloysite nanotubes (HNTs). Our results demonstrate a sustained and extended release of gentamicin from hydrogels enriched with the gentamicin-loaded HNTs. When tested against the gram-negative bacteria, the hydrogel/nanoclay composites showed a pronounced zone of inhibition suggesting that anti-microbial doped nanoclay enriched hydrogels can prevent the growth of bacteria. The release of gentamicin sulfate for a period of five days from the nanoclay-enriched hydrogels would supply anti-microbial agents in a sustained and controlled manner and assist in preventing microbial growth and biofilm formation on the titanium implant surface. A pilot study, using mouse osteoblasts, confirmed that the nanoclay enriched surfaces are also cell supportive as osteoblasts readily, proliferated and produced a type I collagen and proteoglycan matrix.

3.
Biosens Bioelectron ; 30(1): 128-32, 2011 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-21955754

RESUMO

A polymer nanostructured Fabry-Perot interferometer (FPI) based biosensor is reported. Different from a conventional FPI, the nanostructured FPI has a layer of Au-coated nanopores inside its cavity. The Au-coated nanostructure layer offers significant enhancement of optical transducing signals due to the localized surface plasmon resonance effect and also due to the significantly increased sensing surface area, which is up to at least two orders of magnitude larger than that of a conventional FPI-based biosensor. Using this technical platform, the immobilization of captures proteins (protein A) on the nanostructure layer and their binding with immunoglobulin G (IgG) has been monitored in real time, resulting in the shift of the interference fringes of the optical transducing signals. Current results show that the limit-of-detection of the biosensor should be lower than 10 pg/mL for IgG-protein A binding.


Assuntos
Técnicas Biossensoriais/instrumentação , Imunoglobulina G/análise , Interferometria/instrumentação , Nanoestruturas/química , Polímeros/química , Proteína Estafilocócica A/química , Desenho de Equipamento , Análise de Falha de Equipamento , Imunoglobulina G/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA