RESUMO
The purpose of the present cross-sectional clinical study was to check the ability of plaque detection and quantification by QLF-D against conventional digital photographs of disclosed plaque in multibracket appliance (MB) patients. 20 patients were included according to the following criteria: (1) upper and lower jaw treated by MB appliance, (2) patients being 16 years of age or older, (3) all central and lateral incisors as well as canines in situ, (4) absence of developmental defects, carious lesions, surface fillings, prosthetic restorations or recessions greater than 1/3 of root length in central/lateral incisors and canines as well as (5) declaration of consent. QLF-D and conventional photographs were analyzed planimetrically regarding plaque coverage on buccal and oral surfaces of central/lateral incisors and canines. The conventional photographs of stained plaque served as gold standard. On average, in QLF-D pictures 20.7% ± 17.4 of the tooth surfaces were covered with plaque, while the conventional photographs of disclosed plaque presented a mean plaque-covered area of 36.2% ± 23.5. The Bland-Altman plot for both imaging modalities showed a very large inconsistent scattering with both negative and positive deviations. The method discrepancy increased with increasing plaque coverage, thus indicating a systematic method error. On average, the deviation of the methods from the optimal line of accordance was -15.5%. In patients wearing MB appliances, there was no clinical significant agreement regarding the plaque-covered tooth surface depicted by QLF-D respectively conventional images of disclosed plaque. Due to the large method discrepancy, QLF-D is currently not reliable for precise plaque quantification in MB patients.