Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Pharm Bioallied Sci ; 16(Suppl 1): S748-S750, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595537

RESUMO

Objectives: To examine the impact of bisphosphonates (BPs) on dental implant treatment and alveolar bone in post-menopausal ladies. Materials and Methods: Twenty post-menopausal ladies who had at least one dental implant within the previous 5 years participated in the current study. Ten subjects were categorized into two groups: Group A had BP medication for 1.5 years, and group B received parathyroid hormone (PTH). Both groups' bone thickness and bone mineral density (BMD) were measured. Result: Group A had 5%, and group B had 5% of dental implants failures. BMD of cortical bone was 1468 ± 136 mg/mL and 1008 ± 84 mg/mL in groups A and B, correspondingly. The cortical and cancellous bone densities in both the groups were statically significant. Cortical bone thickness was insignificant in comparison. Conclusion: Both cortical and cancellous bones' bone mineral density decreased in both groups. With continued usage of BPs, the cortical bone thickness increased.

2.
J Pharm Bioallied Sci ; 16(Suppl 1): S927-S929, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595369

RESUMO

Objectives: This study compares the precision of cone beam computed tomography (CBCT) and two-dimensional radiography for mini-implant implantation. Materials and Method: For 30 sites (in 15 patients between the ages of 13 and 26 years), the buccal interradicular region among the 2nd premolar and 1st molar was found to be the best location for mini-implants. Next, two groups of the mini-implant implantation process were created. Mini-implants were positioned at the CBCT data-identified sites in the CBCT group. Mini-implants were inserted in the RVG group by using two-dimensional digital radiography and a specially constructed guide. To assess the precision of the mini-implant implantation, post-placement CBCT images were acquired. The obtained data were statistically analyzed. Result: The two groups showed a statistically considerable variation in the mini-implant placement's departure from the optimal height. Due to the smaller interradicular space and decreased convenience in the posterior mandibular area, two out of 15 mini-implants in the RVG group demonstrated root contact in the mandibular jaw. Conclusion: The two-dimensional intraoral radiograph of the interradicular area provides sufficient information for mini-implant placement even though CBCT accurately visualizes the interradicular space in three dimensions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA