1.
Small ; 14(12): e1703334, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29394467

RESUMO

This paper introduces super absorbent polymer valves and colorimetric sensing reagents as enabling components of soft, skin-mounted microfluidic devices designed to capture, store, and chemically analyze sweat released from eccrine glands. The valving technology enables robust means for guiding the flow of sweat from an inlet location into a collection of isolated reservoirs, in a well-defined sequence. Analysis in these reservoirs involves a color responsive indicator of chloride concentration with a formulation tailored to offer stable operation with sensitivity optimized for the relevant physiological range. Evaluations on human subjects with comparisons against ex situ analysis illustrate the practical utility of these advances.


Assuntos
Colorimetria/métodos , Microfluídica/métodos , Polímeros/química , Suor/química , Humanos , Dispositivos Lab-On-A-Chip , Pele/metabolismo
2.
J Breath Res ; 14(1): 016009, 2019 12 16.
Artigo em Inglês | MEDLINE | ID: mdl-31703231

RESUMO

Due to several sources of potential variability associated with exhaled breath bag sampling procedures for off-line analysis, the Respiration Collector for in vitro Analysis (ReCIVA) sampler was developed. Although designed to improve upon several pitfalls of sampling with exhaled breath bags, the ReCIVA remains a minimally studied research tool. In this manuscript, several attributes of the ReCIVA sampler are investigated among three individual tests, such as background contamination, control software version, performance of different adsorbent tubes, duplicate sample production, and comparison to exhaled breath bags. The data shows greater than a 58% reduction in background siloxanes can be achieved with submersion of ReCIVA masks in ethyl alcohol or baking the masks at a high temperature (200 °C). The results illustrate the ReCIVA control software version plays a key role in the flow rates applied to thermal desorption (TD) tubes. Using exhaled isoprene as a representative analyte, the data suggest duplicate samples among ReCIVA pump banks can be achieved using two different thermal desorption tubes, Tenax TA and Tenax/Carbograph 5TD, when using an updated control software and manually calibrating the ReCIVA pumps to uniform flow rates (Tenax p = 0.3869, 5TD p = 0.3131). Additionally, using the updated control software and manual ReCIVA flow calibration, the data suggest the ReCIVA can produce statistically similar results among TD tube types (p = 0.3824) and compared to standard exhaled breath bags (p = 0.1534). Collectively, these results establish a method for manually calibrating the flow of the ReCIVA device to allow for the most consistent results. These data support further experimentation into the use of the ReCIVA sampler for exhaled breath research.


Assuntos
Testes Respiratórios/métodos , Butadienos/análise , Calibragem , Expiração , Hemiterpenos/análise , Humanos , Masculino , Padrões de Referência , Siloxanas/química , Manejo de Espécimes
3.
J Breath Res ; 10(4): 046008, 2016 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-27732570

RESUMO

Exhaled breath is coming to the forefront of non-invasive biomarker discovery efforts. Concentration of exhaled breath volatile organic compounds (VOCs) on thermal desorption (TD) tubes with subsequent analysis by gas chromatography-mass spectrometry (GC-MS) has dominated this field. As discovery experimentation increases in frequency, the need to evaluate the long-term storage stability of exhaled breath VOCs on thermal desorption adsorbent material is critical. To address this gap, exhaled breath was loaded on Tenax TA thermal desorption tubes and stored at various temperature conditions. 74 VOCs, 56 of which have been previously uncharacterized, were monitored using GC-MS over a period of 31 d. The results suggest that storage of exhaled breath at cold temperatures (4 °C) provides the most consistent retention of exhaled breath VOCs temporally. Samples were determined to be stable up to 14 d across storage conditions prior to gaining or losing 1-2 standard deviations in abundance. Through gene set enrichment analysis (GSEA), certain chemical classes were found to be positively (acids) or negatively (sulfur-containing) enriched temporally. By means of field sample collections, the effect of storage and shipping was found to be similar to those studies preformed in the laboratory at 4 °C. Collectively this study not only provides recommendations for proper storage conditions and storage length, but also illustrates the use of GSEA to exhaled breath based GC-MS data.


Assuntos
Testes Respiratórios/métodos , Expiração , Polímeros/análise , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Análise de Componente Principal , Temperatura , Compostos Orgânicos Voláteis/análise