1.
J Mater Sci Mater Med ; 24(8): 1985-92, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23686353

RESUMO

This paper reports the results of an in vitro investigation into the blood response of medical grade poly (vinyl chloride) (PVC), and two types of plasticized PVC in tubing or sheet form, with di-(2-ethylhexyl)phthalate (DEHP) and di(isononyl) cyclohexane-1,2-dicarboxylate (HEXAMOLL(®) DINCH) as plasticizer, were selected for assessment of complement activation, coagulation system and platelet activation. The results of the study show that not only the plasticizers at PVC surface have an influence on complement activation, but also the incubation condition such as incubation time and the diameter of PVC tubing. Under static status, C3a, C5a and SC5b-9 concentration in the blood were higher after contacting with PVC plasticized with DEHP (PVC1) than after contacting with PVC plasticized with DINCH (PVC2). However, under dynamic circulation, the results were totally converse, which may be due to smaller diameter and higher shear rate of PVC2. In addition, there was a significant increase of activated partial thrombin time (APTT) and decrease of FIX concentration after plasma contacting with the PVC tubing, which indicated that the intrinsic pathway may be impacted when blood contacted with PVC tubing. However, there was no significant difference of APTT, FIX concentration and CD62p expression rate between the two materials. Moreover, the migration in the DINCH system was considerably lower than for DEHP, which indicates that DINCH could be a promising alterative plasticizer of DEHP.


Assuntos
Teste de Materiais , Plastificantes/farmacologia , Cloreto de Polivinila/química , Cloreto de Polivinila/farmacologia , Coagulação Sanguínea/efeitos dos fármacos , Ativação do Complemento/efeitos dos fármacos , Complemento C3a/metabolismo , Dietilexilftalato/farmacologia , Humanos , Modelos Biológicos , Selectina-P/metabolismo , Ativação Plaquetária/efeitos dos fármacos , Plasma Rico em Plaquetas/efeitos dos fármacos , Plasma Rico em Plaquetas/metabolismo , Propriedades de Superfície/efeitos dos fármacos , Molhabilidade/efeitos dos fármacos
2.
Zhonghua Zheng Xing Wai Ke Za Zhi ; 21(3): 204-7, 2005 May.
Artigo em Zh | MEDLINE | ID: mdl-16128106

RESUMO

OBJECTIVE: To evaluate the histocompatibility of homologous acellular dermal matrix as a wrapping material for a hydroxyapatite orbital implant and compare the speed of fibrovascular ingrowth in hydroxyapatite orbital implant wrapped with homologous acellular dermal matrix and homologous sclera respectively. METHODS: Twenty four New Zealand rabbits were divided into two groups randomly. One group is implanted with hydroxyapatite orbital implant wrapped with homologous acellular dermal matrix behind the globe, the other group with homologous sclera. The observation included immunological reaction of the globe postoperation. Biopsies of implanted material were taken on weeks 1, 4, 8 and 12 postoperation for histopathological and electron microscope examination. RESULTS: Histological examination showed the homologous acellular dermal matrix has no immunological and inflammatory reaction after implanted in orbit. But the speed of fibrovascular ingrowth is a little slower than that of homologous sclera. CONCLUSIONS: The homologous acellular dermal matrix has the better histocompatibility as an encapsulating biomaterial, it can be a new material instead of homologous sclera.


Assuntos
Materiais Biocompatíveis , Derme/transplante , Implantes Orbitários , Esclera/transplante , Animais , Feminino , Masculino , Coelhos , Transplante Homólogo