1.
Biosens Bioelectron ; 86: 150-155, 2016 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-27362253

RESUMO

In an effort to develop new tools for diagnosing influenza in resource-limited settings, we fabricated a polycarbonate (PC)-polydimethylsiloxane (PDMS) hybrid microchip using a simple epoxy silica sol-gel coating/bonding method and employed it in sensitive detection of influenza virus with Europium nanoparticles (EuNPs). The incorporation of sol-gel material in device fabrication provided functionalized channel surfaces ready for covalent immobilization of primary antibodies and a strong bonding between PDMS substrates and PC supports without increasing background fluorescence. In microchip EuNP immunoassay (µENIA) of inactivated influenza viruses, replacing native PDMS microchips with hybrid microchips allowed the achievement of a 6-fold increase in signal-to-background ratio, a 12-fold and a 6-fold decreases in limit-of-detection (LOD) in influenza A and B tests respectively. Using influenza A samples with known titers, the LOD of influenza µENIA on hybrid microchips was determined to be ~10(4) TCID50 titer/mL and 10(3)-10(4) EID50 titer/mL. A comparison test indicated that the sensitivity of influenza µENIA enhanced using the hybrid microchips even surpassed that of a commercial laboratory influenza ELISA test. In addition to the sensitivity improvement, assay variation was clearly reduced when hybrid microchips instead of native PDMS microchips were used in the µENIA tests. Finally, infectious reference viruses and nasopharyngeal swab patient specimens were successfully tested using µENIA on hybrid microchip platforms, demonstrating the potential of this unique microchip nanoparticle assay in clinical diagnosis of influenza. Meanwhile, the tests showed the necessity of using nucleic acid confirmatory tests to clarify ambiguous test results obtained from prototype or developed point-of-care testing devices for influenza diagnosis.


Assuntos
Dimetilpolisiloxanos/química , Imunoensaio/instrumentação , Vírus da Influenza A/isolamento & purificação , Influenza Humana/virologia , Dispositivos Lab-On-A-Chip , Nanopartículas Metálicas/química , Resinas Epóxi/química , Desenho de Equipamento , Análise de Falha de Equipamento , Európio/química , Humanos , Vírus da Influenza A/imunologia , Influenza Humana/diagnóstico , Influenza Humana/imunologia , Nanopartículas Metálicas/ultraestrutura , Transição de Fase , Cimento de Policarboxilato/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dióxido de Silício/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA