Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Mater Sci Mater Med ; 30(4): 42, 2019 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-30919082

RESUMO

Biodegradable polymers such as polycaprolactone (PCL) are increasingly used for electrospinning substrates for tissue engineering. These materials offer great advantages such as biocompatibility and good mechanical properties. However, in order to be approved for human implantation they have to be sterilized. The impact of commonly used irradiation sterilization methods on electrospun PCL fiber mats was investigated systematically. Electron beam (ß-irradiation), gamma and X-ray irradiation with two different doses (25 and 33 kGy) were investigated. To determine the impact on the fiber mats, mechanical, chemical, thermal properties and crystallinity were investigated. Irradiation resulted in a significant decrease in molecular weight. At the same time, crystallinity of fiber mats increased significantly. However, the mechanical properties did not change significantly upon irradiation, mostly likely because effects of a lower molecular weight were balanced with the higher degree of crystallinity. The irradiation effects were dose dependent, a higher irradiation dose led to stronger changes. Gamma irradiation seemed to be the least suited method, while electron beams (ß irradiation) had a lower impact. Therefore, ß irradiation is recommended as sterilization method for electrospun PCL fiber mats.


Assuntos
Desinfecção/métodos , Membranas Artificiais , Nanofibras/química , Nanofibras/efeitos da radiação , Poliésteres/química , Alicerces Teciduais , Elétrons , Galvanoplastia/métodos , Raios gama , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Poliésteres/efeitos da radiação , Polímeros/química , Polímeros/efeitos da radiação , Esterilização/métodos , Estresse Mecânico , Propriedades de Superfície , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Raios X
2.
PLoS One ; 15(1): e0227563, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31929570

RESUMO

Rotator cuff tear is the most frequent tendon injury in the adult population. Despite current improvements in surgical techniques and the development of grafts, failure rates following tendon reconstruction remain high. New therapies, which aim to restore the topology and functionality of the interface between muscle, tendon and bone, are essentially required. One of the key factors for a successful incorporation of tissue engineered constructs is a rapid ingrowth of cells and tissues, which is dependent on a fast vascularization. The dorsal skinfold chamber model in female BALB/cJZtm mice allows the observation of microhemodynamic parameters in repeated measurements in vivo and therefore the description of the vascularization of different implant materials. In order to promote vascularization of implant material, we compared a porous polymer patch (a commercially available porous polyurethane based scaffold from Biomerix™) with electrospun polycaprolactone (PCL) fiber mats and chitosan-graft-PCL coated electrospun PCL (CS-g-PCL) fiber mats in vivo. Using intravital fluorescence microscopy microcirculatory parameters were analyzed repetitively over 14 days. Vascularization was significantly increased in CS-g-PCL fiber mats at day 14 compared to the porous polymer patch and uncoated PCL fiber mats. Furthermore CS-g-PCL fiber mats showed also a reduced activation of immune cells. Clinically, these are important findings as they indicate that the CS-g-PCL improves the formation of vascularized tissue and the ingrowth of cells into electrospun PCL scaffolds. Especially the combination of enhanced vascularization and the reduction in immune cell activation at the later time points of our study points to an improved clinical outcome after rotator cuff tear repair.


Assuntos
Materiais Biocompatíveis/química , Microcirculação , Poliésteres/química , Lesões do Manguito Rotador/terapia , Animais , Materiais Biocompatíveis/uso terapêutico , Capilares/fisiologia , Quitosana/química , Feminino , Macrófagos/citologia , Macrófagos/metabolismo , Camundongos , Camundongos Endogâmicos BALB C , Microscopia de Fluorescência , Nanofibras/química , Porosidade , Próteses e Implantes , Manguito Rotador/irrigação sanguínea , Lesões do Manguito Rotador/patologia
3.
J Tissue Eng Regen Med ; 14(1): 186-197, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31670896

RESUMO

Acute and chronic rotator cuff tears remain challenging for therapy. A wide range of therapeutic approaches were developed but re-tears and postoperative complications occur regularly. Especially in elderly people, the natural regeneration processes are decelerated, and graft materials are often necessary to stabilize the tendon-to-bone attachment and to improve the healing process. We here investigated in a small animal model a newly developed electrospun polycaprolactone fiber implant coated with a chitosan-polycaprolactone graft copolymer and compared these implants biomechanically and histologically with either a commercially available porous polyurethane implant (Biomerix 3D Scaffold) or suture-fixed tendons. Fifty-one rats were divided into three groups of 17 animals each. In the first surgery, the left infraspinatus tendons of all rats were detached, and the animals recovered for 4 weeks. In the second surgery, the tendons were fixed with suture material only (suture-fixed group; n = 17), whereas in the two experimental groups, the tendons were fixed with suture material and the polyurethane implant (Biomerix scaffold group; n = 17) or the modified electrospun polycaprolactone fiber implant (CS-g-PCL scaffold group; n=17), respectively. The unaffected right infraspinatus tendons were used as native controls. After a recovery of 8 weeks, all animals were clinically inconspicuous. In 12 animals of each group, repaired entheses were biomechanically tested for force at failure, stiffness, and modulus of elasticity, and in five animals, repaired entheses were analyzed histologically. Biomechanically, all parameters did not differ statistically significant between both implant groups, and the entheses failed typically at the surgical site. However, with respect to the force at failure, the median values of the two implant groups were smaller than the median value of the suture-fixed group. Histologically, the modified polycaprolactone fiber implant showed no acute inflammation processes, a good infiltration with cells, ingrowth of blood vessels and tendinous tissue, and a normal fibrous ensheathment. Further improvement of the implant material could be achieved by additional implementation of drug delivery systems. Therewith, the used CS-g-PCL fiber mat is a promising basic material to reach the goal of a clinically usable graft for rotator cuff tear repair.


Assuntos
Quitosana/química , Eletroquímica/métodos , Poliésteres/química , Lesões do Manguito Rotador/cirurgia , Manguito Rotador/cirurgia , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Idoso , Animais , Fenômenos Biomecânicos , Humanos , Masculino , Teste de Materiais , Procedimentos Ortopédicos/métodos , Polímeros/química , Poliuretanos/química , Porosidade , Ratos , Ratos Endogâmicos Lew , Lesões do Manguito Rotador/patologia , Ruptura/patologia , Estresse Mecânico , Suturas , Tendões/patologia , Cicatrização
4.
J Tissue Eng Regen Med ; 13(7): 1190-1202, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31025510

RESUMO

In orthopaedic medicine, connective tissues are often affected by traumatic or degenerative injuries, and surgical intervention is required. Rotator cuff tears are a common cause of shoulder pain and disability among adults. The development of graft materials for bridging the gap between tendon and bone after chronic rotator cuff tears is essentially required. The limiting factor for the clinical success of a tissue engineering construct is a fast and complete vascularization of the construct. Otherwise, immigrating cells are not able to survive for a longer period of time, resulting in the failure of the graft material. The femur chamber allows the observation of microhaemodynamic parameters inside implants located in close vicinity to the femur in repeated measurements in vivo. We compared a porous polymer patch (a commercially available porous polyurethane-based scaffold from Biomerix™) with electrospun polycaprolactone (PCL) fibre mats and chitosan (CS)-graft-PCL modified electrospun PCL (CS-g-PCL) fibre mats in vivo. By means of intravital fluorescence microscopy, microhaemodynamic parameters were analysed repetitively over 20 days at intervals of 3 to 4 days. CS-g-PCL modified fibre mats showed a significantly increased vascularization at Day 10 compared with Day 6 and at Day 14 compared with the porous polymer patch and the unmodified PCL fibre mats at the same day. These results could be verified by histology. In conclusion, a clear improvement in terms of vascularization and biocompatibility is achieved by graft-copolymer modification compared with the unmodified material.


Assuntos
Fêmur/metabolismo , Implantes Experimentais , Teste de Materiais , Neovascularização Fisiológica , Cimento de Policarboxilato , Animais , Quitosana/química , Quitosana/farmacologia , Fêmur/irrigação sanguínea , Fêmur/patologia , Masculino , Cimento de Policarboxilato/química , Cimento de Policarboxilato/farmacologia , Porosidade , Ratos , Ratos Endogâmicos Lew
5.
Colloids Surf B Biointerfaces ; 163: 309-320, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29329076

RESUMO

Electrospun poly(ε-caprolactone) (PCL) fiber mats are modified using a chitosan grafted with PCL (CS-g-PCL), to improve the biological performance and to enable further modifications. The graft copolymer is immobilized by the crystallization of the PCL grafts on the PCL fiber surface as binding mechanism. In this way, the surface of the fibers is covered with chitosan bearing cationic amino groups, which allow adsorption of oppositely charged nanoparticulate drug-delivery systems. The modification of the fiber mats and the attachment of the drug delivery systems are easy and scalable dip processes. The process is also versatile; it is possible to attach different polymeric and inorganic nanoparticulate drug-release systems of cationic or anionic nature. The modifications are verified using scanning electron microscopy (SEM) and confocal laser scanning microscopy (CLSM). As proof of principle, the release of ciprofloxacin from silica nanoparticles attached to the modified fiber mats is shown; however, the method is also suited for other biologically active substances including growth factors. The initial cellular attachment and proliferation as well as vitality of the cells is improved by the modification with CS-g-PCL and is further influenced by the type of the drug delivery system attached. Hence, this method can be used to transfer PCL fiber mats into bioactive implants for in-situ tissue engineering applications.


Assuntos
Ciprofloxacina/farmacologia , Liberação Controlada de Fármacos , Nanofibras/química , Nanopartículas/química , Poliésteres/química , Morte Celular/efeitos dos fármacos , Quitosana/química , Cristalização , Sistemas de Liberação de Medicamentos , Humanos , Nanofibras/ultraestrutura , Poliésteres/síntese química , Espectroscopia de Prótons por Ressonância Magnética , Água/química , Molhabilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA