Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Int J Cardiol ; 383: 24-32, 2023 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-37080466

RESUMO

BACKGROUND: Biodegradable polymer biolimus-eluting stents (BP-BES) may be associated with better outcomes in patients with acute coronary syndromes (ACS) undergoing percutaneous coronary intervention (PCI) compared to other current-generation limus-eluting stents (LES). AIMS: To compare BP-BES with other current-generation LES in ACS patients undergoing PCI. METHODS: We pooled individual data of Non-ST-segment elevation (NSTE)-ACS patients from two large randomized controlled trials (GLASSY and TWILIGHT). The BP-BES groups consisted mostly of GLASSY patients, while the control group (other current-generation LES) included exclusively TWILIGHT patients. The primary outcome was major adverse cardiovascular events (MACE), including cardiovascular death, myocardial infarction, or stent thrombosis; the key secondary outcome was target-vessel failure (TVF). To account for trial design differences, outcomes were assessed at 3 months (short-term) and between 3 and 12 months (long-term) after PCI and subsequently pooled to estimate the 12-month hazards. RESULTS: Of 7107 and 6053 NSTE-ACS patients included in the short- and long-term analysis, 32.7% and 36.5% received a BP-BES, respectively. Risk of MACE associated with BP-BES versus other LES was similar at short-term (1.1% vs 1.3%, adjusted HR 0.86, 95%CI 0.53-1.38), lower at long-term (1.7% vs 3.1%, adjusted HR 0.49, 95%CI 0.34-0.72), and lower in the entire 12-month period (pooled adjusted HR 0.61, 95%CI 0.45-0.82). The cumulative 12-month risk of TVF was reduced with BP-BES (adjusted HR 0.52, 95%CI 0.38-0.70). CONCLUSION: BP-BES was associated with lower 12-month risks of MACE and TVF compared to other current generation LES among NSTE-ACS patients treated with abbreviated or standard ticagrelor-based DAPT. These non-randomized findings are hypothesis-generating. CONDENSED ABSTRACT: Differences in clinical outcomes may exist between biodegradable polymer biolimus-eluting stents (BP-BES) and other current-generation limus-eluting stent (LES) in patients with acute coronary syndrome (ACS). We pooled individual data of about 7000 Non-ST-segment elevation ACS patients undergoing PCI and treated with ticagrelor with or without aspirin from two large randomized controlled trials (GLASSY and TWILIGHT). BP-BES patients derived very largely from GLASSY and other LES patients from TWILIGHT. In this population, BP-BES compared to other current generation LES, were associated with a lower 12-month risk of major adverse cardiovascular events and target-vessel failure.


Assuntos
Síndrome Coronariana Aguda , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/cirurgia , Síndrome Coronariana Aguda/etiologia , Sirolimo , Stents Farmacológicos/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Ticagrelor , Resultado do Tratamento , Stents , Polímeros , Implantes Absorvíveis
2.
JACC Cardiovasc Interv ; 4(1): 98-106, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21251636

RESUMO

OBJECTIVES: This study evaluated the protective effect of nitric oxide-coating of introducer sheath on the local complications in juvenile porcine femoral arteries with similar size to human radial arteries. BACKGROUND: Insertion of an introducer sheath induces vasospasm and transient or permanent vessel occlusion of radial arteries. METHODS: Nitric oxide-coated or control introducer sheaths with or without spasmolytic cocktail (control + C-sheath) were inserted into porcine femoral arteries, followed by percutaneous coronary intervention (PCI). The diameter of the femoral artery at the puncture site, distally and proximally, was measured by quantitative angiography. Histopathological and histomorphometric parameters of the femoral arteries were analyzed 1 h or 1 week after PCI. RESULTS: Insertion of femoral sheath led to mild or severe spasms, with significantly higher vessel diameter at the access site (2.69 ± 0.81 mm vs. 1.77 ± 0.77 mm and 1.85 ± 0.66 mm, p < 0.001), and proximal and distal to it, during PCI in the nitric oxide-sheath group versus the control-sheath and control + C-sheath groups, respectively. Immediately following PCI, significantly less luminal thrombosis (12% vs. 33% and 31% of all analyzed segments, p < 0.001) was observed in the nitric oxide-sheath arteries. At 1 week, lower intimal inflammation score (0.43 ± 11 vs. 1.03 ± 0.35 and 1.04 ± 0.32, p < 0.05), less luminal thrombosis (8% vs. 21% and 30% p < 0.05), and smaller intimal hyperplasia (0.31 ± 0.31 mm(2) vs. 0.47 ± 1.00 mm(2) and 0.86 ± 0.82 mm(2), p < 0.05) were observed in NO-sheath arteries at the injury site. CONCLUSIONS: Nitric oxide coating on the introducer sheath prevents local complications during PCI and results in less vascular thrombosis and inflammation at the access site, contributing to patency of the access vessel with similar size to the radial artery.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Arteriopatias Oclusivas/prevenção & controle , Cateterismo Periférico/instrumentação , Catéteres , Materiais Revestidos Biocompatíveis , Artéria Femoral/efeitos dos fármacos , Óxido Nítrico/administração & dosagem , Vasoconstrição/efeitos dos fármacos , Vasodilatadores/administração & dosagem , Angioplastia Coronária com Balão/efeitos adversos , Animais , Arteriopatias Oclusivas/diagnóstico , Arteriopatias Oclusivas/etiologia , Arteriopatias Oclusivas/fisiopatologia , Cateterismo Periférico/efeitos adversos , Distribuição de Qui-Quadrado , Angiografia Coronária , Desenho de Equipamento , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/patologia , Artéria Femoral/fisiopatologia , Punções , Sus scrofa , Fatores de Tempo , Grau de Desobstrução Vascular/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA