Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Circ J ; 83(7): 1489-1497, 2019 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-31155604

RESUMO

BACKGROUND: There are limited data on the long-term outcome of platinum chromium-based everolimus-eluting stents (PtCr-EES) vs. cobalt chromium-based zotarolimus-eluting stents (CoCr-ZES).Methods and Results:A total of 3,755 patients undergoing percutaneous coronary intervention (PCI) were randomized 2:1 to PtCr-EES or CoCr-ZES, and 96.0% of patients completed the 3-year clinical follow-up. The primary outcome was target lesion failure (TLF), defined as a composite of cardiac death, target vessel-related myocardial infarction (MI), and clinically-driven target lesion revascularization (TLR). At 3 years, TLF occurred in 5.3% and in 5.4% of the PtCr-EES and CoCr-ZES groups, respectively (hazard ratio 0.978; 95% confidence interval 0.730-1.310, P=0.919). There were no significant differences in the individual components of TLF. Routine angiographic follow-up was performed in 38.9% of the total patients. In a landmark analysis of the subgroup that had follow-up angiography, the clinically-driven TLR rate of CoCr-ZES was significantly higher than PtCr-EES group during the angiography follow-up period (P=0.009). Overall definite and probable stent thrombosis rates were very low in both groups (0.5% vs. 0.6%, P=0.677). CONCLUSIONS: PtCr-EES and CoCr-ZES had similar and excellent long-term outcomes in both efficacy and safety after PCI in an all-comer population.


Assuntos
Angiografia Coronária , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea , Sirolimo/análogos & derivados , Idoso , Cromo , Ligas de Cromo , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Platina , Estudos Prospectivos , Falha de Prótese , Sirolimo/administração & dosagem
2.
Biomaterials ; 28(4): 641-9, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17045333

RESUMO

Little is known about the cardioprotective effects against heart failure (HF), the effects on differentiation of bone marrow-derived mononuclear cell (BMMNC), and the biocompatibility of BMMNC-seeded biodegradable poly-glycolide-co-caprolactone (PGCL) scaffolds in a myocardial infarction (MI) animal model. This study hypothesized that implantation of a BMMNC-seeded PGCL scaffold into the epicardial surface in a rat MI model would be biocompatible, induce BMMNC migration into infarcted myocardium, and effectively improve left ventricular (LV) systolic dysfunction. One week after the implantation of a BMMNC-seeded PGCL scaffold, BMMMC showed migration into the epicardial region. Four weeks after implantation, augmented neovascularization was observed in infarcted areas and in infarct border zones. Some BMMNCs exhibited the presence of alpha-MHC and troponin I, markers of differentiation into cardiomyocytes. In echocardiographic examinations, BMMNC-seeded PGCL scaffold and non-cell-seeded simple PGCL scaffold groups effectively reduced progressive LV dilatation and preserved LV systolic function as compared to control rat MI groups. Thus, BMMNC-seeded PGCL scaffolding influences BMMNC migration, differentiation to cardiomyocytes, and induction of neovascularization, ultimately effectively lessening LV remodeling and progressive LV systolic dysfunction. PGCL scaffolding can be considered as an effective treatment alternative in MI-induced advanced HF.


Assuntos
Células da Medula Óssea/citologia , Diferenciação Celular , Monócitos/citologia , Monócitos/transplante , Infarto do Miocárdio/cirurgia , Poliésteres , Engenharia Tecidual/métodos , Animais , Células Cultivadas , Modelos Animais de Doenças , Eletrocardiografia , Microscopia Eletrônica de Varredura , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Ratos , Ratos Sprague-Dawley
3.
J Am Coll Cardiol ; 63(25 Pt A): 2805-16, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24814486

RESUMO

OBJECTIVES: This study sought to test whether the newly developed platinum chromium (PtCr)-based everolimus-eluting stent (EES) is noninferior to the cobalt chromium (CoCr)-based zotarolimus-eluting stent (ZES) in all-comers receiving percutaneous coronary intervention (PCI). BACKGROUND: PtCr provides improved radial strength, conformability, and visibility compared with the CoCr alloy, but PtCr-based stents have not been tested in a wide range of patients receiving PCI. Also, recent case series have raised the issue of longitudinal stent deformation (LSD) with newer drug-eluting stents. METHODS: We randomly assigned 3,755 all-comers receiving PCI to PtCr-EES or CoCr-ZES. The primary outcome was target lesion failure (TLF) at 1-year post-PCI, defined as the composite of cardiac death, nonfatal target vessel-related myocardial infarction, and ischemia-driven target lesion revascularization. Post-hoc angiographic analysis was performed to qualitatively and quantitatively analyze LSD. RESULTS: At 1 year, TLF occurred in 2.9% and 2.9% of the population in the PtCr-EES and CoCr-ZES groups, respectively (superiority p = 0.98, noninferiority p = 0.0247). There were no significant differences in the individual components of TLF as well as the patient-oriented clinical outcome. Of 5,010 stents analyzed, LSD occurred in 0.2% and 0% in the PtCr-EES and CoCr-ZES groups, respectively (p = 0.104). There was no significant difference in post-deployment stent length ratio between the 2 stents (p = 0.352). CONCLUSIONS: At 1 year, PtCr-EES was noninferior to CoCr-ZES in all-comers receiving PCI. Although LSD was observed only in PtCr-EES, both the stent length ratio and the frequency of LSD were not significantly different between the 2 stent types, and PtCr-EES was not associated with adverse clinical outcomes. (Harmonizing Optimal Strategy for Treatment of Coronary Artery Stenosis-SAfety & EffectiveneSS of Drug-ElUting Stents & Anti-platelet REgimen [HOST-ASSURE]; NCT01267734).


Assuntos
Estenose Coronária/tratamento farmacológico , Stents Farmacológicos , Imunossupressores/uso terapêutico , Intervenção Coronária Percutânea/métodos , Inibidores da Agregação Plaquetária/uso terapêutico , Sirolimo/análogos & derivados , Antineoplásicos , Ligas de Cromo , Compostos de Cromo , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Everolimo , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Compostos de Platina , Estudos Prospectivos , Desenho de Prótese , República da Coreia , Método Simples-Cego , Sirolimo/uso terapêutico , Resultado do Tratamento
4.
Can J Cardiol ; 28(5): 612.e5-7, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22575577

RESUMO

Hydrophilic guide wire-related renal artery perforation (RAP) and subsequent retroperitoneal hemorrhage (RPH) during coronary angiography (CAG) is very rare. We present the case of a 68-year-old woman who suffered accidental hydrophilic 0.035-inch guide wire piercing-related RAP and RPH during CAG and coronary intervention. This RAP was diagnosed by bedside ultrasonography and selective renal angiography, and was successfully treated by transcatheter polyvinyl alcohol injection.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Estenose Coronária/terapia , Embolização Terapêutica/métodos , Hemorragia/terapia , Álcool de Polivinil/farmacologia , Artéria Renal/lesões , Idoso , Angioplastia Coronária com Balão/métodos , Cateterismo Cardíaco/efeitos adversos , Dor no Peito/diagnóstico , Dor no Peito/etiologia , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Feminino , Seguimentos , Hemorragia/etiologia , Humanos , Espaço Retroperitoneal , Medição de Risco , Resultado do Tratamento
5.
Trials ; 13: 29, 2012 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-22463698

RESUMO

BACKGROUND: Second-generation drug-eluting stents (DES) have raised the bar of clinical performance. These stents are mostly made from cobalt chromium alloy. A newer generation DES has been developed from platinum chromium alloy, but clinical data regarding the efficacy and safety of the platinum chromium-based everolimus-eluting stent (PtCr-EES) is limited, with no comparison data against the cobalt chromium-based zotarolimus-eluting stent (CoCr-ZES). In addition, an antiplatelet regimen is an integral component of medical therapy after percutaneous coronary intervention (PCI). A 1-week duration of doubling the dose of clopidogrel (double-dose antiplatelet therapy (DDAT)) was shown to improve outcome at 1 month compared with conventional dose in acute coronary syndrome (ACS) patients undergoing PCI. However in Asia, including Korea, the addition of cilostazol (triplet antiplatelet therapy (TAT)) is used more commonly than doubling the dose of clopidogrel in high-risk patients. METHODS: In the 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE) trial, approximately 3,750 patients are being prospectively and randomly assigned in a 2 × 2 factorial design according to the type of stent (PtCr-EES vs CoCr-ZES) and antiplatelet regimen (TAT vs DDAT). The first primary endpoint is target lesion failure at 1 year for the stent comparison, and the second primary endpoint is net clinical outcome at 1 month for comparison of antiplatelet therapy regimen. DISCUSSION: The HOST-ASSURE trial is the largest study yet performed to directly compare the efficacy and safety of the PtCr-EES versus CoCr-ZES in an 'all-comers' population. In addition, this study will also compare the clinical outcome of TAT versus DDAT for 1-month post PCI. TRIAL REGISTRATION: ClincalTrials.gov number NCT01267734.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Estenose Coronária/terapia , Stents Farmacológicos , Inibidores da Agregação Plaquetária/uso terapêutico , Projetos de Pesquisa , Angioplastia Coronária com Balão/efeitos adversos , Cromo , Ligas de Cromo , Estenose Coronária/tratamento farmacológico , Quimioterapia Combinada , Everolimo , Humanos , Inibidores da Agregação Plaquetária/efeitos adversos , Platina , Estudos Prospectivos , Desenho de Prótese , República da Coreia , Método Simples-Cego , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA