Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Mater Sci Mater Med ; 28(10): 145, 2017 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-28823063

RESUMO

For many practitioners, longevity of full glass ceramic crowns in the posterior area, molars and premolars, remains a real challenge. The purpose of this article is to identify and evaluate the parameters that can significantly influence their resistance when preparing a tooth. The analysis proposed in this article relies on interrelated studies conducted at three levels: in vitro (mechanical tests), in silico (finite elements simulations) and in vivo (clinical survival rates). The in vitro and the in silico studies proved that an appropriate variation of the geometric design of the preparations enables to increase up to 80% the mechanical strength of ceramic reconstructions. The in vivo clinical study of CAD/CAM full ceramic crowns was performed in accordance with the principles stated within the in vitro and the in silico studies and provided a 98.97% success rate over a 6 years period. The variations of geometric design parameters for dental preparation allows for reconstructions with a mechanical breaking up to 80% higher than that of a non-appropriate combination. These results are confirmed in clinical practice.


Assuntos
Dente Pré-Molar , Cerâmica , Desenho Assistido por Computador , Dente Molar , Coroa do Dente , Cimentação/métodos , Materiais Dentários , Falha de Restauração Dentária , Humanos , Teste de Materiais , Mecânica
2.
Waste Manag ; 109: 51-64, 2020 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-32388403

RESUMO

Ageing of polymers entails important structural changes and degrades their functional properties, particularly their aspect. Since sorting is a primordial step in recycling to achieve acceptable mechanical properties, the use of promising technologies such as MIR-HSI (Mid-Infrared Hyperspectral Imagery), which could overcome black plastics sorting issue, has to take into account the influence of ageing on identification. As ageing strongly impacts spectra, it can create confusion between materials, especially in an automatized scheme. Based on laboratory FTIR-ATR (Fourier-Transform Infrared Attenuated Total Reflection), this work investigates spectral evolutions of natural and accelerated photodegradation of Waste of Electric and Electrical Equipment plastics (WEEE) as PE, PP, HIPS, ABS and PC to help identifying a polymer despite its ageing degree. Oxidation marks were described and retrieved within a stock of about one hundred of real waste samples, then differentiated from other sources of spectral alteration as formulation. Laboratory ageing data were found to be consistent and often more extreme than real waste samples values. Generally, styrenics showed stronger spectral alteration than polyolefins despite their respective aspects. No significant spectral alteration of PC was obtained here or observed in the waste stock. As an important oxidation marker, the carbonyl peak was also found to often enable fast identification through its wavenumber. If well taken in account, ageing should not induce confusion with other polymers, even formulated, as characteristic signals are different. Finally, the different industrial sub-ranges within MIR are not affected at the same degree, possibly influencing a technological choice for industrial sorting.


Assuntos
Plásticos , Reciclagem , Eletricidade , Indústrias , Polímeros
3.
Waste Manag ; 95: 513-525, 2019 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-31351637

RESUMO

One of the major limitations in polymer recycling is their sorting as they are collected in mixes. The majority of polymers are highly incompatible without compatibilizers. For sorting of polymers, high-speed online Near-Infrared (NIR) spectroscopy is nowadays relatively widespread. It is however limited by the use of carbon black as a pigment and UV-stabilizer, which strongly absorbs near-infrared signals. Mid-Infrared (MIR) hyperspectral cameras were recently put on the market. However, their wavelength ranges are smaller and their resolutions are poorer, in comparison with laboratory equipment based on Fourier-Transform Infrared (FTIR). The identification of specific signals of end-of-life polymers for recycling purposes is becoming an important stake since they are very diverse, highly formulated, and more and more used in copolymers and blends, leading to complex waste stocks mainly as WEEE (Waste Electrical and Electronic Equipment). Dark colored plastics are the major part of WEEE, which also contains mainly styrenics (ABS, HIPS and their blends). In addition, styrenics are especially concerned by the need of identification. In this framework, spectral characterizations of ten types of polymers were scrutinized through about eighty pristine and real waste samples. Polymer characteristic signals were aggregated in charts to help rapid and automatized distinction through specific signals, even in limited resolution and frequency ranges.


Assuntos
Resíduo Eletrônico , Plásticos , Eletricidade , Indústrias , Polímeros , Reciclagem
4.
Waste Manag ; 98: 160-172, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31450178

RESUMO

Sorting at industrial scale is required to perform mechanical recycling of plastics in order to obtain properties that could be competitive with virgin polymers. As a matter of fact, the most part of the various types of plastic waste are not miscible and even compatible. Mid-Infrared (MIR) HyperSpectral Imagery (HSI) is viewed as one of the solutions to the problem of black plastic sorting. Many Waste of Electrical and Electronic Equipment (WEEE) plastics are black. Nowadays, these materials are difficult to sort at an industrial scale because the main used pigment to produce this color, carbon black, masks the Near-Infrared (NIR) spectra of polymers, the currently most used technology for acute sorting in industrial conditions. In this study, laboratory Fourier-Transform Infrared (FTIR) in Attenuated Total Reflection mode (ATR) has been used as a theoretical toolbox based on physical chemistry to help building an automated HSI discrimination despite its limited conditions, especially shorter wavelengths ranges. Weaker resolution and very short acquisition times are other HSI limitations. Helping fast and exhaustive laboratory characterizations of polymeric waste stocks is the other goal of this study. This study focusses on polyolefins as they represent the second biggest fraction of WEEE plastics (WEEP) after styrenics and since little quantities mixed to styrenics during mechanical recycling can lead to important decrease in mechanical properties. Twelve references were thus evaluated and compared between each other and with real waste samples to highlight spectral elements, which can enable differentiation. Charts compiling the signals of discussed polymers were built aiming to the same objective.


Assuntos
Resíduo Eletrônico , Plásticos , Polienos , Polímeros , Reciclagem
5.
Waste Manag ; 56: 438-45, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27425861

RESUMO

In order to produce a high quality recycled material from real deposits of electric and electronic equipment, the rate of impurities in different blended grades of reclaimed materials has to be reduced. Setting up industrial recycling procedures requires to deal with the main types of polymers presents in WEEE (Waste Electric and Electronic Equipment), particularly High Impact Polystyrene (HIPS) as well as other styrenic polymers such as Acrylonitrile-Butadiene-Styrene (ABS), Polystyrene (PS) but also polyolefin which are present into WEEE deposit as Polypropylene (PP). The production of a substantial quantity of recycled materials implies to improve and master the compatibility of different HIPS grades. The influence of polymeric impurities has to be studied since automatic sorting techniques are not able to remove completely these fractions. Investigation of the influence of minor ABS, PS and PP polymer fractions as impurities has been done on microstructure and mechanical properties of HIPS using environmental scanning electron microscopy (ESEM) in order to determine the maximum tolerated rate for each of them into HIPS after sorting and recycling operations.


Assuntos
Resíduo Eletrônico/análise , Poliestirenos/análise , Reciclagem/métodos , Gerenciamento de Resíduos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA