RESUMO
OBJECTIVES: To examine anti-adhesion and anti-biofilm effects of a diamond-like carbon coating deposited via a novel technique on the inner surface of a thin silicon tube. METHODS: Diamond-like carbon coatings were deposited into the lumen of a silicon tube with inner diameters of 2 mm. The surface of the diamond-like carbon was evaluated using physicochemical methods. We used three clinical isolates including green fluorescent protein-expressing Pseudomonas aeruginosa, Escherichia coli and Staphylococcus aureus. We employed a continuous flow system for evaluation of both bacterial adhesion and biofilm formation. Bacterial adhesion assays consisted of counting the number of colony-forming units and visualization of adhered bacterial cells by scanning electron microscope to evaluate the diamond-like carbon-coated/uncoated samples. The biofilm structure was analyzed by confocal laser scanning microscopy on days 3, 5, 7 and 14 for green fluorescent protein-expressing Pseudomonas aeruginosa. RESULTS: The smooth and carbon-rich structure of the intraluminal diamond-like carbon film remained unchanged after the experiments. The numbers of colony-forming units suggested lower adherence of green fluorescent protein-expressing Pseudomonas aeruginosa and Escherichia coli in the diamond-like carbon-coated samples compared with the uncoated samples. The scanning electron microscope images showed adhered green fluorescent protein-expressing Pseudomonas aeruginosa cells without formation of microcolonies on the diamond-like carbon-coated samples. Finally, biofilm formation on the diamond-like carbon-coated samples was lower until at least day 14 compared with the uncoated samples. CONCLUSIONS: Intraluminal diamond-like carbon coating on a silicone tube has anti-adhesion and anti-biofilm effects. This technology can be applied to urinary catheters made from various materials.
Assuntos
Carbono , Cateteres Urinários , Biofilmes , Materiais Revestidos Biocompatíveis/farmacologia , TecnologiaRESUMO
Runx1 is expressed in medial edge epithelial (MEE) cells of the palatal shelf. Conditionally rescued Runx1(-/-) mice showed limited clefting in the anterior junction between the primary and the secondary palatal shelves, but not in the junction between the secondary palates. In wild type mice, the fusing epithelial surface exhibited a rounded cobblestone-like appearance, while such cellular prominence was less evident in the Runx1 mutants. We also found that Fgf18 was expressed in the mesenchyme underlying the MEE and that locally applied FGF18 induced ectopic Runx1 expression in the epithelium of the palatal explants, indicating that Runx1 was induced by mesenchymal Fgf18 signaling. On the other hand, unpaired palatal explant cultures revealed the presence of anterior-posterior (A-P) differences in the MEE fates and fusion mechanism. Interestingly, the location of anterior clefting in Runx1 mutants corresponded to the region with different MEE behavior. These data showed a novel function of Runx1 in morphological changes in the MEE cells in palatal fusion, which is, at least in part, regulated by the mesenchymal Fgf signaling via an epithelial-mesenchymal interaction.