Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Knee Surg Sports Traumatol Arthrosc ; 23(12): 3523-31, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25100486

RESUMO

PURPOSE: With the advent of modular total knee arthroplasty (TKA) systems, backside wear at the articulation between the ultra-high-molecular-weight-polyethylene (UHMWPE) component undersurface and the tibial baseplate has received increasing attention as a source of clinically significant polyethylene wear debris. The aim of this study was to investigate the reciprocating interface at the TKA undersurface articulation using profilometry after in vivo service. Our null hypothesis was that there would be no discernible pattern or relationship between the metal tibial baseplate and UHMWPE surface profile. METHODS: A nanoscale analysis of thirty retrieved fixed-bearing TKA explants was performed. Surface roughness (Sa) and skewness (Ssk) were measured on both the UHMWPE component undersurface and the tibial baseplate of explants using a non-contacting profilometer (1 nm resolution). Four pristine unimplanted components of two different designs (Stryker Kinemax and DePuy PFC) were examined for control purposes. RESULTS: Mean explant baseplate surface roughness was 1.24 µm (0.04-3.01 µm). Mean explant UHMWPE undersurface roughness was 1.16 µm (0.23-2.44 µm). Each explant had an individual roughness pattern with unique baseplate and undersurface UHMWPE surface roughness that was different from, but closely related to, surface topography observed in control implants of the same manufacturer and design. Following in vivo service, UHMWPE undersurface showed changes towards a negative skewness, demonstrating that wear is occurring at the backside interface. CONCLUSION: In vivo loading of the TKA prosthesis leads to measurable changes in surface profile at the backside articulation, which appear to be dependent on several factors including implant design and in vivo duration. These findings are consistent with wear occurring at this surface. Findings of this study would support the use of a polished tibial tray over an unpolished design in total knee arthroplasty with the goal of reducing PE wear by means of providing a smoother backside countersurface for the UHMWPE component.


Assuntos
Artroplastia do Joelho/instrumentação , Análise de Falha de Equipamento , Prótese do Joelho , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo , Humanos , Metais , Pessoa de Meia-Idade , Polietileno , Polietilenos , Desenho de Prótese , Falha de Prótese , Reoperação , Tíbia/cirurgia
2.
Acta Orthop ; 86(1): 32-40, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25301437

RESUMO

BACKGROUND AND PURPOSE: There has been a recent trend towards the use of greater femoral head sizes in an attempt to improve function and enhance stability after primary hip replacement. This has been associated with the use of alternative bearings, theoretically to reduce wear and improve implant longevity. METHODS: We examined the influence of these variables on patient-reported outcome measures (PROMs) for a consecutive series of primary hip replacements using National Joint Registry (NJR) and PROMs-linked data. To minimize the confounding influence of implant design factors, the single most commonly used brand in England and Wales (DePuy Corail Pinnacle) was examined. Improvement in patient hip-specific outcomes (Oxford hip score, OHS), general health outcomes (Euroqol, EQ-5D), and rates of self-reported complications (bleeding, wound problems, re-admission, and reoperation) were compared for different head sizes (28-mm, 32-mm, and 36-mm) and bearings (metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), and ceramic-on-ceramic (CoC)), adjusting for differences in case mix. RESULTS: At a mean follow-up of 7 months, improvements in OHS and EQ5D index were similar for 28-mm and 36-mm heads. A 32-mm head was associated with poorer function (OHS: 20, 99% CI: 19-21, p = 0.002; EQ5D index: 0.39, 99% CI: 0.36-0.42, p = 0.004), although these small differences may not be of clinical importance. There were no statistically significant benefits of either CoP or CoC bearings compared to a MoP bearing. Complication rates were similar within comparisons of head sizes or bearings. INTERPRETATION: In this short-term study, we did not find any functional benefits of larger head sizes or alternative bearings, after adjusting for other influences. We question their use in routine primary hip replacement given the lack of evidence of improved long-term survival in the literature.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Desenho de Prótese , Sistema de Registros , Adulto , Idoso , Idoso de 80 Anos ou mais , Cerâmica , Estudos de Coortes , Inglaterra , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Avaliação de Resultados da Assistência ao Paciente , Polietileno , Resultado do Tratamento , País de Gales
3.
Acta Orthop ; 86(1): 7-17, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25285617

RESUMO

BACKGROUND AND PURPOSE: The optimal hip replacement for young patients remains unknown. We compared patient-reported outcome measures (PROMs), revision risk, and implant costs over a range of hip replacements. METHODS: We included hip replacements for osteoarthritis in patients under 60 years of age performed between 2003 and 2010 using the commonest brand of cemented, cementless, hybrid, or resurfacing prosthesis (11,622 women and 13,087 men). The reference implant comprised a cemented stem with a conventional polyethylene cemented cup and a standard-sized head (28- or 32-mm). Differences in implant survival were assessed using competing-risks models, adjusted for known prognostic influences. Analysis of covariance was used to assess improvement in PROMs (Oxford hip score (OHS) and EQ5D index) in 2014 linked procedures. RESULTS: In males, PROMs and implant survival were similar across all types of implants. In females, revision was statistically significantly higher in hard-bearing and/or small-stem cementless implants (hazard ratio (HR) = 4) and resurfacings (small head sizes (< 48 mm): HR = 6; large head sizes (≥ 48 mm): HR = 5) when compared to the reference cemented implant. In component combinations with equivalent survival, women reported significantly greater improvements in OHS with hybrid implants (22, p = 0.006) and cementless implants (21, p = 0.03) (reference, 18), but similar EQ5D index. For men and women, National Health Service (NHS) costs were lowest with the reference implant and highest with a hard-bearing cementless replacement. INTERPRETATION: In young women, hybrids offer a balance of good early functional improvement and low revision risk. Fully cementless and resurfacing components are more costly and do not provide any additional benefit for younger patients.


Assuntos
Artroplastia de Quadril/métodos , Cimentação/métodos , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Sistema de Registros , Adolescente , Adulto , Estudos de Coortes , Inglaterra , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados da Assistência ao Paciente , Modelos de Riscos Proporcionais , Reoperação/estatística & dados numéricos , Fatores Sexuais , Resultado do Tratamento , País de Gales , Adulto Jovem
4.
J Arthroplasty ; 28(7): 1152-1159.e1, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23523210

RESUMO

This retrospective cohort study of a National Joint Registry data examines survival time to revision following the commonest brand of primary hybrid THA, exploring risk factors independently associated with failure. Overall 5-year revision was 1.56%. In the final adjusted model, revision risk was significantly higher with standard polyethylene (PE) liners (metal-on-PE: hazard ratio [HR]=2.52, P=0.005, ceramic-on-PE: HR=2.99, P=0.025) when compared to metal-on-highly-cross-linked (XL) PE. Risk of revision with ceramic-on-ceramic bearings was borderline significant (HR=1.86, P=0.061). A significant interaction between age and acetabular shell type (solid or multi-hole) was found (P=0.022), suggesting that solid shells performed significantly better in younger patients. In summary, we found that there were significant differences in implant failure between different bearing surfaces and shell types after adjusting for a range of covariates.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Reoperação/estatística & dados numéricos , Idoso , Cerâmica , Feminino , Humanos , Masculino , Metais , Polietileno , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Falha de Prótese , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/cirurgia , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Reino Unido/epidemiologia
5.
J Bone Joint Surg Am ; 102(2): 119-127, 2020 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-31725123

RESUMO

BACKGROUND: There is evidence to support the use of highly cross-linked polyethylene (HXLPE) in patients undergoing total hip arthroplasty. However, the benefits for those undergoing total knee arthroplasty are uncertain, with conflicting reports based on previous cohort analyses. The purpose of the present study was to compare the revision rates following primary total knee arthroplasty with use of HXLPE as compared with conventional polyethylene (CPE) using data from the National Joint Registry (NJR) for England, Wales and Northern Ireland. METHODS: We performed a retrospective analysis of primary total knee arthroplasties recorded in the NJR from 2003 to 2014. Cobalt-chromium (CoCr)-CPE and CoCr-HXLPE bearing surfaces were compared using all-cause revision, aseptic revision, and septic revision as end points. Survival analyses were conducted using rates per 100 years observed, Kaplan-Meier survival estimates, and Cox regression hazard ratios (HRs) adjusted for age, sex, American Society of Anesthesiologists (ASA) classification, body mass index (BMI), lead surgeon grade, and implant constraint. Secondary analyses compared the most commonly used HXLPEs (Zimmer Prolong, DePuy XLK, and Stryker X3) against CPE for the 3 most common total knee arthroplasty systems (NexGen, PFC Sigma, and Triathlon). RESULTS: In the present study of 550,658 total knee arthroplasties, the unadjusted aseptic revision rates were significantly lower following procedures performed with CPE (n = 513,744) as compared with those performed with HXLPE total knee replacements (n = 36,914) (0.29 [95% confidence interval (CI), 0.28 to 0.30] compared to 0.38 [95% CI, 0.35 to 0.42], p < 0.01). The 10-year HR associated with CPE was 0.4 (95% CI, 0.1 to 0.8, p = 0.03). There were no significant differences between the adjusted revision rates of HXPLE compared with CPE in individual analyses of the most common total knee arthroplasty systems. However, for the subset of patients who were both <60 years of age and had a BMI of >35 kg/m, the "second-generation" Stryker X3 HXLPE demonstrated significantly better survival than its respective CPE, with CPE having an HR of 2.6 (95% CI, 1.2 to 5.9) (p = 0.02). CONCLUSIONS: Alternative bearings are marketed as having improved wear properties over traditional CoCr-CPE. This registry-based analysis demonstrated no overall survival benefit of HXLPE after a maximum duration of follow-up of 12 years. Because of their increased cost, the routine use of HXLPE bearings may not be justified. However, they may have a role in specific "higher demand" groups such as patients <60 years of age and/or those with a BMI of >35 kg/m. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete list of levels of evidence.


Assuntos
Artroplastia do Joelho/instrumentação , Prótese do Joelho , Polietileno/uso terapêutico , Idoso , Inglaterra , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Irlanda do Norte , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Infecção da Ferida Cirúrgica/etiologia , País de Gales
6.
Bone Joint J ; 101-B(11): 1331-1347, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31674244

RESUMO

AIMS: Antibiotic-loaded bone cements (ALBCs) may offer early protection against the formation of bacterial biofilm after joint arthroplasty. Use in hip arthroplasty is widely accepted, but there is a lack of evidence in total knee arthroplasty (TKA). The objective of this study was to evaluate the use of ALBC in a large population of TKA patients. MATERIALS AND METHODS: Data from the National Joint Registry (NJR) of England and Wales were obtained for all primary cemented TKAs between March 2003 and July 2016. Patient, implant, and surgical variables were analyzed. Cox proportional hazards models were used to assess the influence of ALBC on risk of revision. Body mass index (BMI) data were available in a subset of patients. RESULTS: Of 731 214 TKAs, 15 295 (2.1%) were implanted with plain cement and 715 919 (97.9%) with ALBC. There were 13 391 revisions; 2391 were performed for infection. After adjusting for other variables, ALBC had a significantly lower risk of revision for any cause (hazard ratio (HR) 0.85, 95% confidence interval (CI) 0.77 to 0.93; p < 0.001). ALBC was associated with a lower risk of revision for all aseptic causes (HR 0.85, 95% CI 0.77 to 0.95; p < 0.001) and revisions for infection (HR 0.84, 95% CI 0.67 to 1.01; p = 0.06). The results were similar when BMI was added into the model, and in a subanalysis where surgeons using only ALBC over the entire study period were excluded. Prosthesis survival at ten years for TKAs implanted with ALBC was 96.3% (95% CI 96.3 to 96.4) compared with 95.5% (95% CI 95.0 to 95.9) in those implanted with plain cement. On a population level, where 100 000 TKAs are performed annually, this difference represents 870 fewer revisions at ten years in the ALBC group. CONCLUSION: After adjusting for a range of variables, ALBC was associated with a significantly lower risk of revision in this registry-based study of an entire nation of primary cemented knee arthroplasties. Using ALBC does not appear to increase midterm implant failure rates. Cite this article: Bone Joint J 2019;101-B:1331-1347.


Assuntos
Antibacterianos/administração & dosagem , Artroplastia do Joelho/métodos , Cimentos Ósseos , Prótese do Joelho/efeitos adversos , Adulto , Idoso , Anticoagulantes/uso terapêutico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Infecções Relacionadas à Prótese/prevenção & controle , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Tromboembolia/prevenção & controle , Resultado do Tratamento
7.
PLoS One ; 10(11): e0140309, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26561859

RESUMO

BACKGROUND: Hip replacement is one of the most commonly performed surgical procedures worldwide; hundreds of implant configurations provide options for femoral head size, joint surface material and fixation method with dramatically varying costs. Robust comparative evidence to inform the choice of implant is needed. This retrospective cohort study uses linked national databases from England and Wales to determine the optimal type of replacement for patients over 60 years undergoing hip replacement for osteoarthritis. METHODS AND FINDINGS: Implants included were the commonest brand from each of the four types of replacement (cemented, cementless, hybrid and resurfacing); the reference prosthesis was the cemented hip procedure. Patient reported outcome scores (PROMs), costs and risk of repeat (revision) surgery were examined. Multivariable analyses included analysis of covariance to assess improvement in PROMs (Oxford hip score, OHS, and EQ5D index) (9159 linked episodes) and competing risks modelling of implant survival (79,775 procedures). Cost of implants and ancillary equipment were obtained from National Health Service procurement data. RESULTS: EQ5D score improvements (at 6 months) were similar for all hip replacement types. In females, revision risk was significantly higher in cementless hip prostheses (hazard ratio, HR = 2.22, p<0.001), when compared to the reference hip. Although improvement in OHS was statistically higher (22.1 versus 20.5, p<0.001) for cementless implants, this small difference is unlikely to be clinically important. In males, revision risk was significantly higher in cementless (HR = 1.95, p = 0.003) and resurfacing implants, HR = 3.46, p<0.001), with no differences in OHS. Material costs were lowest with the reference implant (cemented, range £1103 to £1524) and highest with cementless implants (£1928 to £4285). Limitations include the design of the study, which is intrinsically vulnerable to omitted variables, a paucity of long-term implant survival data (reflecting the duration of data collection), the possibility of revision under-reporting, response bias within PROMs data, and issues associated with current outcome scoring systems, which may not accurately reflect level of improvement in some patients. CONCLUSIONS: Cement fixation, using a polyethylene cup and a standard sized head offers good outcomes, with the lowest risks and at the lowest costs. The most commonly used cementless and resurfacing implants were associated with higher risk of revision and were more costly, while perceptions of improved function and longevity were unsupported.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Prótese de Quadril/estatística & dados numéricos , Osteoartrite do Quadril/cirurgia , Sistema de Registros/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Cimentos Ósseos/química , Análise Custo-Benefício , Inglaterra , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Avaliação de Resultados em Cuidados de Saúde/economia , Avaliação de Resultados em Cuidados de Saúde/métodos , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Polietileno , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Inquéritos e Questionários , País de Gales
8.
Injury ; 44(6): 730-4, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23206920

RESUMO

National guidelines recommend cemented hemiarthroplasty for intracapsular fractured neck of femur (NOF), based on evidence of less pain, better mobility and lower costs. We aimed to compare complications following cemented and cementless implants, using the national hospital episode statistics (HES) database in England. Dislocation, revision, return to theatre and medical complications were extracted for all patients with NOF fracture who underwent hemiarthroplasty between January 2005 and December 2008. To make a 'like for like' comparison all 30,424 patients with a cementless implant were matched to 30,424 cemented implants (from a total of 42,838) in terms of age, sex and Charlson co-morbidity score. In the cementless group, 18-month revision (1.62% versus 0.57% (OR 2.90, p<0.001)), 4-year revision (2.45% versus 1.11% (OR 2.28, p<0.001)) and 30-day chest infection (8.14% versus 7.23% (OR 1.14, p=0.028)) were significantly higher. Four-year dislocation rate was higher in cemented implants (0.60% versus 0.26% (OR 0.45, p<0.001)). No significant differences were seen in return to theatre or other medical complications. In this national analysis of matched patients mid-term revision and perioperative chest infection was significantly higher in the cementless group. This supports the published evidence and national guidelines recommending cement fixation of hemiarthroplasty.


Assuntos
Cimentos Ósseos/uso terapêutico , Fraturas do Colo Femoral/epidemiologia , Fraturas do Colo Femoral/cirurgia , Hemiartroplastia/métodos , Idoso , Idoso de 80 Anos ou mais , Análise Custo-Benefício , Feminino , Luxação do Quadril/etiologia , Luxação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Dor/etiologia , Guias de Prática Clínica como Assunto , Sistema de Registros , Reoperação , Taxa de Sobrevida , Resultado do Tratamento , Reino Unido/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA