Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Clin Oral Investig ; 27(9): 5439-5448, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37479870

RESUMO

OBJECTIVE: To investigate the characteristics of particle generation and dispersion during dental procedure using digital inline holography (DIH) METHODS: Particles at two locations, near-field and far-field, which represent the field closer to the procedure location and within 0.5 m from the procedure location respectively, are studied using two different DIH systems. The effect of three parameters namely rotational speed, coolant flow rate, and bur angle on particle generation and dispersion are evaluated by using 10 different operating conditions. The particle characteristics at different operating conditions are estimated from the holograms using machine learning-based analysis. RESULTS: The particle concentration decreased by at least two orders of magnitude between the near-field and far-field locations across the 10 different operating conditions, indicating significant dispersion of the particles. High rotational speed is found to produce a larger number of smaller particles, while lower rotational speeds generate larger particles. Coolant flow rate is found to have a greater impact on particle transport to the far-field location. Irregular shape dental particles account for 29% of total particles at far-field location, with the majority of these irregular shape particles having diameters ranging from 12 to 18 µm. CONCLUSIONS: All three parameters have significant effects on particle generation and dispersion, with rotational speed having a more significant influence on particle generation at near-field and coolant flow rate playing a more important role on particle transport to the far-field. CLINICAL RELEVANCE: This study provides valuable insights on particle characteristics during high-speed drilling. It can help dental professionals minimize exposure risks for themselves and patients by optimizing clinical operating conditions.

2.
J Am Dent Assoc ; 152(12): 981-990, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34538418

RESUMO

BACKGROUND: Dental procedures often produce aerosols and spatter, which have the potential to transmit pathogens such as severe acute respiratory syndrome coronavirus 2. The existing literature is limited. METHODS: Aerosols and spatter were generated from an ultrasonic scaling procedure on a dental manikin and characterized via 2 optical imaging methods: digital inline holography and laser sheet imaging. Capture efficiencies of various aerosol mitigation devices were evaluated and compared. RESULTS: The ultrasonic scaling procedure generated a wide size range of aerosols (up to a few hundred µm) and occasional large spatter, which emit at low velocity (mostly < 3 m/s). Use of a saliva ejector and high-volume evacuator (HVE) resulted in overall reductions of 63% and 88%, respectively, whereas an extraoral local extractor (ELE) resulted in a reduction of 96% at the nominal design flow setting. CONCLUSIONS: The study results showed that the use of ELE or HVE significantly reduced aerosol and spatter emission. The use of HVE generally requires an additional person to assist a dental hygienist, whereas an ELE can be operated hands free when a dental hygienist is performing ultrasonic scaling and other operations. PRACTICAL IMPLICATIONS: An ELE aids in the reduction of aerosols and spatters during ultrasonic scaling procedures, potentially reducing transmission of oral or respiratory pathogens like severe acute respiratory syndrome coronavirus 2. Position and airflow of the device are important to effective aerosol mitigation.


Assuntos
COVID-19 , Ultrassom , Aerossóis , Raspagem Dentária , Humanos , SARS-CoV-2
3.
Phys Rev E ; 95(5-1): 052408, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28618627

RESUMO

We compare forces resisting DNA packaging and forces driving DNA ejection in bacteriophage phi29 with theoretical predictions. Ejection of DNA from prohead-motor complexes is triggered by heating complexes after in vitro packaging and force is inferred from the suppression of ejection by applied osmotic pressure. Ejection force from 0% to 80% filling is found to be in quantitative agreement with predictions of a continuum mechanics model that assumes a repulsive DNA-DNA interaction potential based on DNA condensation studies and predicts an inverse-spool conformation. Force resisting DNA packaging from ∼80% to 100% filling inferred from optical tweezers studies is also consistent with the predictions of this model. The striking agreement with these two different measurements suggests that the overall energetics of DNA packaging is well described by the model. However, since electron microscopy studies of phi29 do not reveal a spool conformation, our findings suggest that the spool model overestimates the role of bending rigidity and underestimates the role of intrastrand repulsion. Below ∼80% filling the inferred forces resisting packaging are unexpectedly lower than the inferred ejection forces, suggesting that in this filling range the forces are less accurately determined or strongly temperature dependent.


Assuntos
Fagos Bacilares/fisiologia , Empacotamento do DNA , DNA Viral , Integração Viral , Fenômenos Biomecânicos , Empacotamento do DNA/fisiologia , DNA Viral/fisiologia , Elasticidade , Tamanho do Genoma , Microscopia Eletrônica , Modelos Biológicos , Conformação de Ácido Nucleico , Pinças Ópticas , Pressão Osmótica , Polietilenoglicóis , Montagem de Vírus/fisiologia , Integração Viral/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA