Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Proc Natl Acad Sci U S A ; 114(34): E7054-E7062, 2017 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-28784765

RESUMO

The ELISA is the mainstay for sensitive and quantitative detection of protein analytes. Despite its utility, ELISA is time-consuming, resource-intensive, and infrastructure-dependent, limiting its availability in resource-limited regions. Here, we describe a self-contained immunoassay platform (the "D4 assay") that converts the sandwich immunoassay into a point-of-care test (POCT). The D4 assay is fabricated by inkjet printing assay reagents as microarrays on nanoscale polymer brushes on glass chips, so that all reagents are "on-chip," and these chips show durable storage stability without cold storage. The D4 assay can interrogate multiple analytes from a drop of blood, is compatible with a smartphone detector, and displays analytical figures of merit that are comparable to standard laboratory-based ELISA in whole blood. These attributes of the D4 POCT have the potential to democratize access to high-performance immunoassays in resource-limited settings without sacrificing their performance.


Assuntos
Análise Química do Sangue/métodos , Imunoensaio/métodos , Polímeros/química , Biomarcadores/sangue , Análise Química do Sangue/instrumentação , Desenho de Equipamento , Humanos , Imunoensaio/instrumentação , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Leptina/sangue , Sistemas Automatizados de Assistência Junto ao Leito , Impressão
2.
Methods Mol Biol ; 2393: 343-365, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34837189

RESUMO

Sandwich immunoassays are the gold standard for detection of protein analytes. Here, we describe an ultrasensitive point-of-care sandwich immunoassay platform for the detection of biomarkers directly from blood or serum using a custom-built smartphone detector. Testing undiluted blood or serum is challenging due to the complexity of the matrix. Proteins nonspecifically adsorb to and cells often adhere to the assay surface, which can drastically impact the analytical sensitivity of the assay. To address this problem, our assay is built upon a "nonfouling" polymer brush "grafted from" a glass slide, which eliminates nearly all nonspecific binding and therefore increases the signal-to-noise ratio and greatly improves the analytical performance of the test. The two components required to perform a sandwich immunoassay are inkjet-printed directly onto the surface: (1) "stable" capture antibodies that remain entrapped in the brush even after exposure to a liquid sample and (2) fluorescently labeled "soluble" detection antibodies that dissolve upon exposure to a liquid sample. The polymer brush provides hydration to the antibodies, allowing them to remain stable and active over prolonged periods of time. When a liquid sample containing a biomarker of interest is dispensed onto the chip, the detection antibodies dissolve and diffuse to the stable capture spots forming a complex that sandwiches the analyte and that has a fluorescence intensity proportional to the concentration of the biomarker in solution, which can be measured using a custom-built smartphone detector. As multiple capture antibodies can be printed as discrete capture spots, the assay can be easily multiplexed without the need for multiple fluorophores. This chip and detector platform can be utilized for the point-of-care detection of low-abundance biomarkers directly from blood or serum in low-resource settings.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Smartphone , Anticorpos , Biomarcadores , Imunoensaio , Polímeros
3.
Biofabrication ; 12(2): 025004, 2020 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-31778993

RESUMO

Printing is a promising method to reduce the cost of fabricating biomedical devices. While there have been significant advancements in direct-write printing techniques, non-contact printing of biological reagents has been almost exclusively limited to inkjet printing. Motivated by this lacuna, this work investigated aerosol jet printing (AJP) of biological reagents onto a nonfouling polymer brush to fabricate in vitro diagnostic (IVD) assays. The ultrasonication ink delivery process, which had previously been reported to damage DNA molecules, caused no degradation of printed proteins, allowing printing of a streptavidin-biotin binding assay with sub-nanogram ml-1 analytical sensitivity. Furthermore, a carcinoembryogenic antigen IVD was printed and found to have sensitivities in the clinically relevant range (limit of detection of approximately 0.5 ng ml-1 and a dynamic range of approximately three orders of magnitude). Finally, the multi-material printing capabilities of the aerosol jet printer were demonstrated by printing silver nanowires and streptavidin as interconnected patterns in the same print job without removal of the substrate from the printer, which will facilitate the fabrication of mixed-material devices. As cost, versatility, and ink usage become more prominent factors in the development of IVDs, this work has shown that AJP should become a more widely considered technique for fabrication.


Assuntos
Bioimpressão/instrumentação , Impressão Tridimensional/instrumentação , Bioimpressão/métodos , Tinta , Polímeros/química , Impressão , Prata/química , Ultrassom
4.
Adv Mater ; 32(2): e1903285, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31782843

RESUMO

"Nonfouling" polymer brush surfaces can greatly improve the performance of in vitro diagnostic (IVD) assays due to the reduction of nonspecific protein adsorption and consequent improvement of signal-to-noise ratios. The development of synthetic polymer brush architectures that suppress adventitious protein adsorption is reviewed, and their integration into surface plasmon resonance and fluorescent sandwich immunoassay formats is discussed. Also, highlighted is a novel, self-contained immunoassay platform (the D4 assay) that transforms time-consuming laboratory-based assays into a user-friendly and point-of-care format with a sensitivity and specificity comparable or better than standard enzyme-linked immunosorbent assay (ELISA) directly from unprocessed samples. These advancements clearly demonstrate the utility of nonfouling polymer brushes as a substrate for ultrasensitive and robust diagnostic assays that may be suitable for clinical testing, in field and laboratory settings.


Assuntos
Imunoensaio/métodos , Polímeros/química , Incrustação Biológica , Humanos , Testes Imediatos
5.
Adv Healthc Mater ; 8(8): e1801177, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30908902

RESUMO

Poly(ethylene glycol) (PEG), a linear polymer known for its "stealth" properties, is commonly used to passivate the surface of biomedical implants and devices, and it is conjugated to biologic drugs to improve their pharmacokinetics. However, its antigenicity is a growing concern. Here, the antigenicity of PEG is investigated when assembled in a poly(oligoethylene glycol) methacrylate (POEGMA) "bottlebrush" configuration on a planar surface. Using ethylene glycol (EG) repeat lengths of the POEGMA sidechains as a tunable parameter for optimization, POEGMA brushes with sidechain lengths of two and three EG repeats are identified as the optimal polymer architecture to minimize binding of anti-PEG antibodies (APAs), while retaining resistance to nonspecific binding by bovine serum albumin and cultured cells. Binding of backbone- versus endgroup-selective APAs to POEGMA brushes is further investigated, and finally the antigenicity of POEGMA coatings is assessed against APA-positive clinical plasma samples. These results are applied toward fabricating immunoassays on POEGMA surfaces with minimal reactivity toward APAs while retaining a low limit-of-detection for the analyte. Taken together, these results offer useful design concepts to reduce the antigenicity of polymer brush-based surface coatings used in applications involving human or animal matrices.


Assuntos
Antígenos , Materiais Revestidos Biocompatíveis , Polietilenoglicóis , Animais , Anticorpos/análise , Anticorpos/metabolismo , Antígenos/química , Antígenos/imunologia , Antígenos/metabolismo , Antígenos/ultraestrutura , Materiais Revestidos Biocompatíveis/efeitos adversos , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/metabolismo , Camundongos , Células NIH 3T3 , Polietilenoglicóis/química , Polietilenoglicóis/metabolismo , Próteses e Implantes , Soroalbumina Bovina/química , Soroalbumina Bovina/metabolismo , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA