Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Oral Investig ; 27(8): 4389-4399, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37166534

RESUMO

OBJECTIVE: Evaluating various polishing methods after bracket debonding and excessive attachment material removal for different ceramics and pretreatments. MATERIAL AND METHODS: Zirconia (ZrO2), leucite (LEU) and lithium disilicate (LiSi) specimens were pretreated with a) silica coated alumina particles (CoJet); LEU and LiSi additionally with b) hydrofluoric acid (HF), c) Monobond Etch&Prime (MEP), d) silicium carbide grinder (SiC) before bracket bonding, shearing off, ARI evaluation, excessive attachment material removal and polishing with i) Sof-Lex Discs (Soflex), ii) polishing paste (Paste), iii) polishing set (Set). Before/after polishing surface roughness (Ra) was measured with a profilometer. Martens hardness parameter were also assessed. RESULTS: Irrespective of pretreatment Ra of LEU increased the most, followed by LiSi and ZrO2 (p < 0.001, SiC: p = 0.012), in accordance with the measured Martens hardness parameter. CoJet/SiC caused greater roughness as HF/MEP (p < 0.001). The ZrO2 surface was rougher after polishing with Paste/Set (p < 0.001; p = 0.047). Ra improved in the LEU/CoJet, LEU/SiC and LiSi/SiC groups with Soflex/Set (p < 0.001), in the LiSi/CoJet and LEU/HF groups by Soflex (p = 0.003, p < 0.001) and worsened by Paste (p = 0.017, p < 0.001). Polishing of HF or MEP pretreated LiSi with Set increased Ra (p = 0.001, p < 0.001), so did Paste in the LEU/MEP group (p < 0.001). CONCLUSIONS: Paste couldn't improve the surfaces. Soflex was the only method decreasing Ra on rough surfaces and not causing roughness worsening. Polishing of LEU/LiSi after MEP, LEU after HF pretreatment doesn´t seem to have any benefit. CLINICAL RELEVANCE: To avoid long-term damage to ceramic restorations, special attention should be paid to the polishing method after orthodontic treatment.


Assuntos
Cerâmica , Zircônio , Zircônio/química , Teste de Materiais , Cerâmica/química , Porcelana Dentária/química , Propriedades de Superfície , Polimento Dentário/métodos
2.
Clin Oral Investig ; 26(3): 2827-2837, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34792666

RESUMO

OBJECTIVE: The study aims to investigate the shear bond strength (SBS) between silicate ceramic restorations and ceramic brackets after different pretreatments and aging methods. MATERIAL AND METHODS: Leucite (LEU) and lithium disilicate (LiSi) specimens were pretreated with (i) 4% hydrofluoric acid + silane (HF), (ii) Monobond Etch&Prime (MEP), (iii) silicatization + silane (CoJet), and (iv) SiC grinder + silane (SiC). Molars etched (phosphoric acid) and conditioned acted as comparison group. SBS was measured after 24 h (distilled water, 37 °C), 500 × thermocycling (5/55 °C), and 90 days (distilled water, 37 °C). Data was analyzed using Shapiro-Wilk, Kruskal-Wallis with Dunn's post hoc test and Bonferroni correction, Mann-Whitney U, and Chi2 test (p < 0.05). The adhesive remnant index (ARI) was determined. RESULTS: LEU pretreated with MEP showed lower SBS than pretreated with HF, CoJet, or SiC. LiSi pretreated with MEP resulted in lower initial SBS than pretreated with HF or SiC. After thermocycling, pretreatment using MEP led to lower SBS than with CoJet. Within LiSi group, after 90 days, the pretreatment using SiC resulted in lowest SBS values. After HF and MEP pretreatment, LEU showed lower initial SBS than LiSi. After 90 days of water storage, within specimens pretreated using CoJet or SiC showed LEU higher SBS than LiSi. Enamel presented higher or comparable SBS values to LEU and LiSi. With exception of MEP pretreatment, ARI 3 was predominantly observed, regardless the substrate, pretreatment, and aging level. CONCLUSIONS: MEP pretreatment presented the lowest SBS values, regardless the silicate ceramic and aging level. Further research is necessary. CLINICAL RELEVANCE: There is no need for intraoral application of HF for orthodontic treatment.


Assuntos
Colagem Dentária , Braquetes Ortodônticos , Cerâmica/química , Teste de Materiais , Cimentos de Resina , Resistência ao Cisalhamento , Silanos/química , Silicatos , Propriedades de Superfície
3.
J Orofac Orthop ; 2023 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-36826527

RESUMO

PURPOSE: To compare the long-term outcome quality (≥ 15 years) of Class II:1 treatment using either a bionator (BIO) or a Herbst-multibracket appliance (HMB). METHODS: Patients who underwent functional treatment during the ideal treatment period for the respective approach (prepuberty vs. peak/postpeak) were assessed. Inclusion criteria were overjet ≥ 4 mm, skeletal Class II and availability of study casts from before, after and ≥ 15 years after treatment. The study casts were assessed using the Peer Assessment Rating (PAR) index and standard orthodontic cast measurements. RESULTS: During treatment, PAR score, overjet and sagittal occlusal relationship improved significantly in all groups. Long-term, there was a significant increase of incisor irregularity in the upper (HMB) and lower (BIO) arch and a significant decrease of lower arch width 3 - 3 (BIO). PAR score, overjet, and sagittal occlusal relationship remained stable long-term. Intergroup comparisons revealed significant differences between the BIO and HMB groups in terms of lower arch width (6 - 6), upper and lower arch width (3 + 3/3 - 3) as well as sagittal molar relationship. CONCLUSIONS: The achieved improvement in PAR score, overjet, and sagittal occlusion remained comparably stable long-term in all groups. The long-term changes are probably a consequence of natural aging.

4.
Angle Orthod ; 2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36744874

RESUMO

OBJECTIVES: To investigate skeletal and dentoskeletal changes 20 years after bionator treatment. MATERIALS AND METHODS: Analog lateral cephalograms of 18 subjects treated with a bionator appliance during growth were digitized with a transmitted light scanner. Inclusion criteria were: increased overjet (≥4 mm), skeletal Class II, available lateral cephalograms before (T0), after (T1), and 20 years after (T2) treatment with only a Bionator. To assess standard cephalometric parameters, the software ivoris analyze was used. Data were analyzed using Friedman's two-way analysis of variance by ranks followed by Dunn's post hoc tests (P ≤ .05). RESULTS: During therapy (T0-T1), ANB decreased significantly by 1.9° and remained unchanged long term. SNA slightly decreased (-0.6°) during treatment, SNB and SNPg increased (+1.4°, +1.7°). All three parameters showed a significant increase at T2 (+1.2°, +1.6°, +1.6°). Vertical measurements (ML-NL, ML-NSL, NL-NSL) remained almost unchanged during therapy. NL-NSL also was unchanged during the long-term interval; ML-NSL and ML-NL decreased significantly (-3.4°, -4.9°). During treatment, the maxillary incisors retroclined (OK1-NL: -1.6°, OK1-NA: -0.6°), the mandibular incisors proclined (UK1-ML: +3.5°, UK1-NB: +4.9°), neither significantly. Long term, there was a nonsignificant tendency toward proclination of upper (OK1-NL: +0.1°, OK1-NA: +0.7°) and retroclination of lower incisors (UK1-ML: -1.5°, UK1-NB: -5°). CONCLUSIONS: Changes of ANB after bionator treatment without additional fixed appliances remained stable after 20 years. The observed long-term changes are probably consequences of well-known physiological and age-related processes.

5.
Dent Mater ; 39(2): 170-180, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36610899

RESUMO

OBJECTIVE: Investigating the impact of different pretreatment methods, attachment materials and aging regimens on shear bond strength (SBS) between zirconia and indirectly bonded brackets using CAD/CAM transfer trays. METHODS: Zirconia substrates were conditioned with silica coated alumina (CoJet) and a) Clearfil Ceramic Primer Plus (CF), b) RelyX Ceramic Primer (RXP), c) Futurabond U (FU). Brackets were virtually placed, transfer tray designed (OnyxCeph) and 3D-printed for indirect bonding with a) Transbond LV (TBL), b) Nexus NX3 (NX3), c) Maximum Cure (MC). SBS testing was performed with a universal testing machine after 24 h, 500 thermal cycles, 90 d. Directly bonded brackets to human enamel using Transbond XT Adhesive served as control. The adhesive remnant index (ARI) was evaluated. Data was analyzed with Shapiro-Wilk, Kruskal-Wallis and Dunn's post-hoc test with Bonferroni correction, Chi2 test (p < 0.05), and the Weibull modulus was calculated. RESULTS: SBS ranged from 0.1 to 15.5 MPa and were influenced mostly by the attachment material. NX3 generally showed the highest values (9.5-15.8 MPa). Initially RXP/TBL and FU/TBL presented the lowest values (4.3/4.8 MPa). Aging regimens reduced SBS of MC irrespective of pretreatment, after 90 d values ranged from 0.1 to 0.9 MPa. ARI 1 was predominant in all MC groups and FU/NX3, 2 and 3 in the other groups. Weibull moduli ranged between 0.15 (MC/RXP/500 TC) and 6.24 (NX3/RXP/500 TC). SIGNIFICANCE: MC seems not to be suitable for indirect bonding using CAD/CAM transfer trays to zirconia. NX3 showed similar SBS values compared to the control, TBL lower.


Assuntos
Colagem Dentária , Braquetes Ortodônticos , Humanos , Cimentos de Resina/química , Bis-Fenol A-Glicidil Metacrilato/química , Esmalte Dentário , Cerâmica , Resistência ao Cisalhamento , Teste de Materiais , Colagem Dentária/métodos
6.
Sci Rep ; 12(1): 8514, 2022 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-35595815

RESUMO

To investigate the influence of different pretreatment methods, attachment materials and artificial aging on shear bond strength (SBS) between monolithic zirconia and metal brackets. Zirconia substrates were pretreated with silica coated alumina (CoJet) and (1) clearfill ceramic primer plus (CF), (2) RelyX ceramic primer (RXP), (3) Futurabond U (FU). The brackets were bonded with (1) Transbond XT Adhesive (TB), (2) BrackFix Adhesive (BF), (3) bracepaste adhesive (BP). SBS was tested after 24 h, 500 thermal cycles, 90 d at 37 °C with a universal testing machine. SBS values reached from 8.3 to 16.9 MPa. The Weibull moduli ranged between 0.37 (RXP combined with BP after 90 d) and 7.42 (CF combined with TB after 24 h). The pretreatment with FU after 90 d, independent of the attachment material, and RXP with BF resulted in the lowest SBS values 8.3-9.9 MPa, the combination of RXP or CF with TB showed the highest (13.2-16.9 MPa) independent of aging. After FU pretreatment the proportion of ARI 1 and 0 was higher, of ARI 3 lower as after CF and RXP pretreatment. All tested combinations showed sufficiently high SBS values for clinical use. Pretreatment with FU presented the lowest values after 90 days.


Assuntos
Braquetes Ortodônticos , Cerâmica/química , Teste de Materiais , Resistência ao Cisalhamento , Propriedades de Superfície , Zircônio
7.
Monogr Oral Sci ; 29: 201-213, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33427218

RESUMO

Dental biofilms can cause major oral diseases like gingivitis, periodontitis, and caries. Orthodontic appliances promote supra- and subgingival biofilm accumulation, alter the oral microbiome, and hamper oral hygiene. Orthodontic treatment can be associated with adverse effects, such as enamel decalcification, gingivitis, and periodontal disease. The aim of this review is to summarize the changes in supra- and subgingival biofilm and periodontal tissues during and after orthodontic treatment. Studies have reported elevated levels of Streptococcus mutans and periodontopathogenic bacteria in patients undergoing orthodontic treatment. In general, the microbial changes and periodontal parameters decreased to pretreatment levels after appliance removal. Nevertheless, some adverse effects associated with orthodontic treatment are not reversible, such as enamel decalcifications caused by metabolic products of high levels of cariogenic bacteria. The evidence suggests that the roughness and constituents of the orthodontic materials influence the bacterial colonization. Therefore, several antibacterial orthodontic bonding systems, which show antibacterial effects in vitro, have been developed. The importance of adequate oral hygiene should be emphasized to all orthodontic patients. They should be frequently reminded and motivated to obtain a good oral hygiene. The evidence from the current literature suggests the safest way for orthodontic treatment in periodontally diseased patients may be after successful completion of the periodontal therapy. However, the exact time point needs to be better clarified in future studies.


Assuntos
Cárie Dentária , Gengivite , Biofilmes , Cárie Dentária/terapia , Humanos , Aparelhos Ortodônticos/efeitos adversos , Streptococcus mutans
8.
Sci Rep ; 11(1): 16611, 2021 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-34400744

RESUMO

To evaluate the shear bond strength (SBS) of different attachment materials used for lingual bonding, the influence of artificial aging and the radii of curvature of the enamel surface on SBS, 192 third molars were photographed to determine the radius of curvature of the oral surface. After phosphoric acid etching a cylindrical test piece was bonded to the oral enamel using a mold that was filled with a chemically curing (Maximum Cure, Transbond IDB Premix) or a dual-curing (Nexus NX3, RelyX Unicem2) attachment material. SBS was tested after 24 h, 500 thermal cycles or 90 days at 37 °C with a universal testing machine. Computed tomography scans were performed to determine the bonded surface and calculate SBS. Values ranged from 8.3 to 20.9 MPa. RelyX Unicem2 showed the highest SBS values at baseline, 500 thermal cycles and after 90 days (p < 0.001). Ninety days of wet storage significantly reduced SBS of Maximum Cure (p = 0.028). The radius of curvature correlated positively with SBS (rs = 0.204, p = 0.005). The SBS of all attachment materials was sufficient for clinical use, even after artificial aging. RelyX Unicem2 showed almost twice as high SBS values as the other attachment materials.

9.
Dent Mater ; 36(3): 420-430, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32007315

RESUMO

OBJECTIVES: To test and compare five pressable lithium-X-silicate-ceramics on their mechanical and wear properties. METHODS: Specimens were pressed and prepared from: i. Amber Press (AP), ii. Celtra Press (CP), iii. Initial LiSi Press (IL), iv. Livento Press (LP), and v. IPS e.max Press (IE). Four-point flexural strength (FS), SEVNB fracture toughness (KIC), three-body wear (3BW), Martens hardness (HM) and indentation modulus (EIT) were measured. For CP, FS and HM were measured with and without additional Power Firing. Each subgroup contained 15 specimens. Data were analyzed using Kolmogorov-Smirnov, one-way ANOVA followed by Scheffé test, Kruskal-Wallis-H-, Mann-Whitney-U-, and Spearman-Rho-test (p < 0.05). The Weibull modulus was calculated using the maximum likelihood estimation method. RESULTS: AP and CP presented higher FS than IL. LP presented the highest Weibull modulus. CP showed lower KIC values than AP, and AP was not significant compared to LP and IE. The most 3BW material loss was observed for CP. CP revealed higher HM values than the remaining ceramics. IL presented lower EIT compared to AP and CP. The following correlations were observed between the test parameters: 3BW with FS (r = 0.279, p = 0.015), with HM (r = -0.378, p = 0.001), and with EIT (r = -0.344, p = 0.004); EIT with FS (r = 0.203, p = 0.028); and HM with FT (r = -0.223, p = 0.027) and EIT (r = 0.884, p < 0.001). No correlations were observed between FS and KIC (r = 0.046; p = 0.346). SIGNIFICANCE: AP followed by LP showed the highest and IL followed by CP the lowest properties tested. Power Firing of CP improved the flexural strength. Ceramics with high flexural strength and Martens parameters showed lower wear. Materials with high Martens hardness presented lower fracture toughness values and ones with high indentation modulus showed high flexural strength.


Assuntos
Resistência à Flexão , Mustelidae , Animais , Cerâmica , Porcelana Dentária , Dureza , Lítio , Teste de Materiais , Silicatos , Propriedades de Superfície
10.
Angle Orthod ; 90(2): 209-215, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31483143

RESUMO

OBJECTIVE: To investigate changes in dental arch configuration, relationship, and malocclusion directly after Class II malocclusion treatment with a Balters bionator modified by Ascher as well as 20 years after treatment. MATERIALS AND METHODS: Orthodontic dental cast analysis of 18 patients with skeletal Class II treated with a bionator without any additional fixed therapy was performed with a digital caliper at three stages: before (T0), after (T1) and 20 years after (T2) treatment. Arch perimeter and depth, intermolar and intercanine distance, overjet, overbite, sagittal molar and canine relationship, mandibular incisor irregularity (Little's index), and malocclusion (PAR index) were assessed. RESULTS: During treatment (T0-T1), upper arch perimeter significantly increased with a significant decrease in the upper and lower arch perimeter long-term (T1-T2), whereas corresponding arch depths changed only slightly in both periods. Transverse intermolar width increased significantly during treatment, remaining almost constant from T1 to T2. Lower intercanine distance remained fairly unchanged during treatment, but decreased significantly during follow-up. Lower incisor irregularity improved slightly during treatment but increased significantly long-term. After treatment, sagittal molar relationships on both sides were improved, overjet and overbite reduced; these significant changes remained stable long-term. The peer assessment rating (PAR) index was significantly lower after treatment and increased insignificantly during follow-up. CONCLUSIONS: 20 years after bionator treatment without additional fixed appliances, the improved sagittal relationship and the reduced overjet and PAR index remained fairly stable. Long-term changes are most likely due to physiological aging processes and are not associated with bionator treatment.


Assuntos
Aparelhos Ativadores , Maxila , Cefalometria , Arco Dental , Seguimentos , Humanos , Mandíbula , Maxila/anatomia & histologia , Modelos Dentários , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA