RESUMO
PURPOSE: To report the 3-year results of Innova™ stent implantation for the treatment of femoropopliteal (FP) lesions in a real-world setting. METHODS: This single-arm, retrospective, multicenter clinical study analyzed 481 lesions from 453 consecutive patients with symptomatic peripheral artery diseases (Rutherford category 1-6) who underwent endovascular therapy with implantation of Innova™ self-expanding nitinol stent for FP lesions. The primary outcome measure was the 3-year restenosis rate based on doppler-ultrasound or angiographic criteria. The secondary outcome measures included the rates of 3-year major amputation and major adverse limb events. RESULTS: Restenosis following Innova™ implantation was found in 61% of the cases at 3 years. At the end of 3 years, the rates of major amputations and major adverse limb events were 3 and 31%, respectively. In cases free from restenosis at 1 year, no predictive factors for restenosis at 3 years could be determined. CONCLUSION: The present study demonstrated mid-term clinical outcomes after Innova™ stent implantation for the treatment of FP lesions in a real-world population. The Innova™ stent demonstrated acceptable clinical outcomes in a real-world setting.
Assuntos
Doença Arterial Periférica , Artéria Poplítea , Ligas , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Humanos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/cirurgia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/cirurgia , Desenho de Prótese , Estudos Retrospectivos , Stents , Resultado do Tratamento , Grau de Desobstrução VascularRESUMO
AIM: Although the InnovaTM self-expanding nitinol stent (Boston Scientific, Marlborough, MA) exhibits acceptable performance in long-term safety and efficacy when used for the treatment of femoropopliteal (FP) lesions, clinical outcomes following its implantation have not been systematically studied in real-world settings. We investigated the one-year clinical outcomes after implantation of InnovaTM self-expanding nitinol stents for the treatment of FP lesions in real-world settings. METHODS: In this multicenter study, 481 lesions in 453 consecutive patients with peripheral artery disease (PAD) (74±9 years; male, 70%; diabetes mellitus, 61%; dialysis, 27%; critical limb ischemia, 37%) who underwent endovascular therapy with the implantation of InnovaTM self-expanding nitinol stents for FP lesions were analyzed from February 2016 to April 2017. The primary endpoint was one-year restenosis, whereas the secondary endpoints included one-year major adverse limb events and predictors for one-year restenosis. RESULTS: The mean lesion length was 18±10 cm. One-year restenosis and major adverse limb event rates were 36% and 18%, respectively. Multivariate analysis revealed that the presence of diabetes mellitus (odds ratio [OR]: 1.83; 95% confidence interval [CI]: 1.07-3.13), distal reference vessel diameter (OR: 1.86; 95% CI: 1.09-3.16), spot stenting (OR: 2.27; 95% CI: 1.27-4.06), and lack of one-year cilostazol treatment (OR: 0.58; 95% CI: 0.33-1.00) were independent risk factors for one-year restenosis. CONCLUSION: The current study demonstrated one-year clinical outcomes after InnovaTM self-expanding nitinol stent placement for the treatment of FP lesions, including challenging cases in real-world settings.