Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Prosthet Dent ; 117(4): 459-462, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27881326

RESUMO

The esthetics and biocompatibility of ceramic resin-bonded fixed dental prostheses (RBFDPs) are regarded as better than those of their metal ceramic counterparts. However, a high incidence of complications in the posterior arches of ceramic RBFDPs initiated a process of continuous and evolving design development. This clinical report describes 2 successful restorations of a missing posterior tooth with monolithic zirconia RBFDPs with 2 different retainer designs: retentively prepared adhesive wings and inlays.


Assuntos
Prótese Adesiva , Restaurações Intracoronárias/métodos , Perda de Dente/cirurgia , Idoso , Cetirizina , Colagem Dentária/métodos , Planejamento de Dentadura , Estética Dentária , Feminino , Humanos , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos
2.
Clin Oral Implants Res ; 23(6): 719-725, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21812819

RESUMO

OBJECTIVES: Evaluation of the effect of different span length and preparation designs on the fracture load of tooth-implant-supported fixed dental prostheses (TIFDPs) manufactured from yttrium-stabilized zirconia frameworks. MATERIAL AND METHODS: Forty-eight TIFDPs were manufactured using a CAD/CAM system and veneered with a press ceramic. Rigidly mounted implants (SLA, diameter 4.1 mm, length 10 mm) in the molar region with a titanium abutment were embedded in PMMA bases pairwise with premolars. All premolars were covered with heat-shrink tubing to simulate physiological tooth mobility. Six different test groups were prepared (a) differing in the preparation design of the premolar (inlay [i]; crown [c]), (b) the material of the premolar (metal [m]; natural human [h]) and (c) the length of the TIFDPs (3-unit [3]; 4-unit [4]). All TIFDPs underwent thermomechanical loading (TCML) (10,000 × 6.5°/60°; 6 × 10(5) × 50 N). The load to fracture (N) was measured and fracture sites were evaluated macroscopically. RESULTS: None of the restorations failed during TCML. The mean fracture loads (standard deviations) were 1,522 N (249) for the 3-unit, inlay-retained TIFDPs on a metal abutment tooth (3-im), 1,910 N (165) for the 3-cm group, 1,049 N (183) for group 4-im, 1,274 N (282) for group 4-cm, 1,229 N (174) for group 4-ih and 911 N (205) for group 4-ch. Initial damages within the veneering ceramic occurred before the final failure of the restoration. The corresponding loads were 24-52% lower than the fracture load values. CONCLUSIONS: All restorations tested could withstand the mastication forces expected. Fracture-load values for 3- and 4-unit inlay-crown and crown-crown-retained TIFDPs should spur further clinical investigation.


Assuntos
Materiais Dentários/química , Porcelana Dentária/química , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Prótese Parcial Fixa , Arcada Parcialmente Edêntula/reabilitação , Zircônio/química , Força de Mordida , Cimentação , Desenho Assistido por Computador , Dente Suporte , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Humanos , Teste de Materiais , Modelos Dentários , Estatísticas não Paramétricas , Titânio , Torque , Ítrio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA