Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Foot Ankle Surg ; 59(1): 86-90, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31882153

RESUMO

Currently, Achilles tendon rupture repair is surgically addressed with an open or minimally invasive approach using a heavy, nonabsorbable suture in a locking stitch configuration. However, these sutures have low stiffness and a propensity to stretch, which can result in gapping at the repair site. Our study compares a new multifilament stainless steel cable-crimp repair method to a standard Krackow repair using multistrand, ultra-high molecular weight polyethylene polyester sutures. Eight matched pairs of cadavers were randomly assigned for Achilles tendon repair using either Krackow technique with polyethylene polyester sutures or the multifilament stainless steel cable-crimp technique. Each repair was cyclically loaded from 10 to 50 N for 100 loading cycles, followed by a linear increase in load until complete failure of the repair. During cyclic loading, 4 of the 8 Krackow polyethylene polyester suture repairs failed, whereas none of the multifilament stainless steel cable crimp repairs failed. Load to failure was greater for the multifilament stainless steel cable crimp repairs (321.03 ± 118.71 N) than for the Krackow polyethylene polyester suture repairs (132.47 ± 103.39 N, p = .0078). The ultimate tensile strength of the multifilament stainless steel cable crimp repairs was also greater than that of the Krackow polyethylene polyester suture repairs (485.69 ± 47.93 N vs 378.71 ± 107.23 N, respectively, p = .12). The mode of failure was by suture breakage at the crimp for all cable-crimp repairs and by suture breakage at the knot, within the tendon, or suture pullout for the polyethylene polyester suture repairs. The multifilament stainless steel cable crimp construct may be a better alternative for Achilles tendon rupture repairs.


Assuntos
Tendão do Calcâneo/cirurgia , Polietilenos , Aço Inoxidável , Técnicas de Sutura , Suturas , Traumatismos dos Tendões/cirurgia , Tendão do Calcâneo/lesões , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Resistência à Tração
2.
J Knee Surg ; 35(8): 916-921, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33231279

RESUMO

The purpose of this study was to determine patient-reported outcomes, hardware removal rates, as well as conversion to arthroplasty at mid-term follow-up following high tibial osteotomy (HTO) with a modern polyetheretherketone (PEEK) system. All PEEK system-based HTOs performed at a single institution between January 2010 and January 2016 with a minimum of 2 years follow-up were reviewed. Rates of postoperative complications, hardware removal and conversion to arthroplasty were calculated. Patient-reported outcomes including visual analog pain scale (VAS), Tegner activity scale, Lysholm, Knee Injury and Osteoarthritis Outcome Score (KOOS), and 36-Item Short Form Survey (SF-36) were obtained. Forty-seven HTOs in 43 patients (mean age: 37.6 ± 10.8 years; 30 M, 13 F) were followed for a mean of 6.0 ± 1.5 years. A total of four postoperative complications occurred in three patients, resulting in an overall complication rate of 6.4%. Hardware removal occurred in three patients at a mean of 0.73 ± 0.53 years after surgery, with overall survival free of hardware removal of 96% (95% confidence interval [CI]: 85-99) at 1 year, 94% (95% CI: 82-98) at 2 years, and 94% (95% CI: 82-98) at 8 years. Conversion to arthroplasty occurred in three patients at a mean of 3.2 ± 1.0 years after surgery, with mean survival of 100% (95% CI: 94-100) at 1 year, 100% (95% CI: 94-100) at 2 years, and 93% (95% CI: 81-98) at 8 years. VAS at rest improved, from 3.1 ± 2.5 preoperatively to 1.1 ± 1.6 postoperatively (p < 0.001). Patients remained active, with a mean Tegner activity scale of 4.4 ± 1.4 at final follow-up and satisfactory Lysholm, KOOS, and SF-36 scores. At mid-term follow-up, medial opening-wedge HTO using a modern PEEK-based system was found to be safe, efficacious, and durable, with satisfactory outcome scores and a low rate of conversion to arthroplasty. PEEK-based implants were found to have low hardware removal rates of 6% at 5 years, which compares favorably to historic metal fixation. This is a Level III study.


Assuntos
Osteoartrite do Joelho , Tíbia , Adulto , Benzofenonas , Seguimentos , Humanos , Articulação do Joelho/cirurgia , Pessoa de Meia-Idade , Osteoartrite do Joelho/complicações , Osteotomia/métodos , Polímeros , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Tíbia/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA