Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Clin Oral Implants Res ; 25(2): e83-9, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23088616

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the axial displacement of the abutments during clinical procedures by the tightening torque and cyclic loading. MATERIALS AND METHODS: Two different implant-abutment connection systems were used (external butt joint connection [EXT]; internal tapered conical connection [INT]). The master casts with two implant replicas, angulated 10° from each other, were fabricated for each implant connection system. Four types of impression copings were assembled and tightened with the corresponding implants (hex transfer impression coping, non-hex transfer impression coping, hex pick-up impression coping, non-hex pick-up impression coping). Resin splinted abutments and final prosthesis were assembled. The axial displacement was measured from the length of each assembly, which was evaluated repeatedly, after 30 Ncm torque tightening. After 250 N cyclic loading of final prosthesis for 1,000,000 cycles, additional axial displacement was recorded. The mean axial displacement was statistically analyzed (repeated measured ANOVA). RESULTS: There was more axial displacement in the INT group than that of the EXT group in impression copings, resin splinted abutments, and final prosthesis. Less axial displacement was found at 1-piece non-hex transfer type impression coping than other type of impression copings in the INT group. There was more axial displacement at the final prosthesis than resin splinted abutments in the INT and the EXT groups. After 250 N cyclic loading of final prosthesis, the INT group showed more axial displacement than that of the EXT group. CONCLUSION: Internal tapered conical connection demonstrated a varying amount of axial displacement with tightening torque and cyclic loading.


Assuntos
Dente Suporte , Implantes Dentários , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Materiais para Moldagem Odontológica , Técnica de Moldagem Odontológica , Prótese Dentária Fixada por Implante , Modelos Dentários , Torque
2.
J Adv Prosthodont ; 15(6): 302-314, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38205121

RESUMO

PURPOSE: The aim of this study was to classify the shapes of retromolar pads and assess their morphometric differences using a 3D model. MATERIALS AND METHODS: Two hundred fully edentulous or Kennedy Class I partially edentulous patients (400 retromolar pads) were enrolled. Scan data of the definitive mandibular casts produced through functional impressions were obtained using a 3D laser scanner. Seven parameters (transverse diameter, longitudinal diameter, transverse-contour length, longitudinal-contour length, longitudinal/transverse diameter ratio, longitudinal/transverse-contour length ratio, and angle of the retromolar pad line to the residual alveolar ridge line) were measured using image analysis software. Subsequently, the pads were classified according to the shape. Statistical analyses were performed using 95% confidence intervals. RESULTS: Classifying the retromolar pads into three shapes led to high intra-examiner reliability (Cronbach's alpha = 0.933). The pear shape was the most common (56.5%), followed by oval/round (27.7%) and triangular (15.8%) shapes. There were no significant differences between the left and right sides according to the shape and no significant differences in any parameter according to age. The transverse diameter and longitudinal/transverse diameter ratio differed between sexes (P < .05). The triangular shape had a significantly different transverse diameter, transverse-contour length, longitudinal/transverse diameter ratio, and longitudinal/transverse-contour length ratio compared with the pear and oval/round shapes (P < .05). CONCLUSION: From a clinical reliability standpoint, classifying retromolar pads into three shapes (oval/round, pear-shaped, and triangular) is effective. The differences in the sizes among the shapes were attributed to the transverse measurement values.

3.
Nano Lett ; 11(9): 3881-6, 2011 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-21790143

RESUMO

This paper describes the fabrication and design principles for using transparent graphene interconnects in stretchable arrays of microscale inorganic light emitting diodes (LEDs) on rubber substrates. We demonstrate several appealing properties of graphene for this purpose, including its ability to spontaneously conform to significant surface topography, in a manner that yields effective contacts even to deep, recessed device regions. Mechanics modeling reveals the fundamental aspects of this process, as well as the use of the same layers of graphene for interconnects designed to accommodate strains of 100% or more, in a completely reversible fashion. These attributes are compatible with conventional thin film processing and can yield high-performance devices in transparent layouts. Graphene interconnects possess attractive features for both existing and emerging applications of LEDs in information display, biomedical systems, and other environments.


Assuntos
Grafite/química , Nanotecnologia/métodos , Adesividade , Luz , Microscopia Eletrônica de Varredura/métodos , Modelos Teóricos , Óptica e Fotônica , Borracha , Dióxido de Silício/química , Análise Espectral Raman/métodos , Propriedades de Superfície
4.
Clin Oral Implants Res ; 21(8): 848-56, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20384707

RESUMO

OBJECTIVES: This study examined the bone response of magnesium (Mg) ion-implanted implants produced using a plasma source ion implantation method. MATERIALS AND METHODS: The surface characteristics were evaluated by scanning electron microscopy, Auger electron spectroscopy, X-ray photoelectron spectroscopy, and Rutherford backscattering spectroscopy. The screw-type titanium implants were treated with resorbable blasting media (RBM) and divided into one control group (RBM implants) and three test groups (Mg ion-implanted implants with different retained Mg doses). Twenty-four implants from each group were placed into the tibiae of 24 New Zealand white rabbits. After allowing 6 weeks for healing, the removal torque (RTQ) was measured and the implants were subjected to histomorphometric analysis. RESULTS: The surface roughness and surface morphology of the test groups were similar. The Mg ion-implanted implants with a 2.3 x 10(15) ions/cm(2) retained dose showed a significantly higher RTQ than the other implants. Histomorphometric analysis indicated that the bone contact of this group was superior to the other groups. CONCLUSION: The bone response of Mg ion-implanted implant showed results superior or similar to an RBM-treated implant. The optimal Mg ion concentration that induced the strongest osseointegration was approximately 9%.


Assuntos
Implantes Dentários , Materiais Dentários/química , Eletroquímica/métodos , Magnésio/química , Tíbia/cirurgia , Análise de Variância , Animais , Fosfatos de Cálcio/química , Análise do Estresse Dentário , Microscopia Eletrônica de Varredura , Osseointegração , Espectroscopia Fotoeletrônica , Coelhos , Estatísticas não Paramétricas , Propriedades de Superfície , Retalhos Cirúrgicos , Titânio/química , Torque
5.
J Adv Prosthodont ; 5(3): 359-63, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24049579

RESUMO

This article describes the treatment provided to a patient with the maxillary anterior teeth exhibiting severe secondary caries beneath the previous restoration and a white spot lesion on the adjacent incisor. Two implants were placed after extraction of hopeless teeth with the guided bone regeneration technique. A white spot lesion of the adjacent incisor was treated with minimally invasive treatment. This clinical report describes the multidisciplinary treatment for the white spot lesion and esthetic restoration of missing anterior teeth.

6.
J Adv Prosthodont ; 2(4): 154-9, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21264195

RESUMO

BACKGROUND: Generalized aggressive periodontitis (GAP) is a destructive periodontal disease that can develop in young age. Only a few cases of full mouth rehabilitation, using dental implants, have been reported in a patient with aggressive periodontitis. CASE DESCRIPTION: This clinical report describes the treatment procedures and results of full mouth rehabilitation in a patient with aggressive periodontitis. After all teeth were extracted, 6 implants were placed in the maxilla and mandible, respectively. Fixed detachable implant prostheses were made. The patient was satisfied with the final results. She was followed for 10 months postloading. CLINICAL IMPLICATION: For a long-term success, continuous maintenance care is critical, as the contributing factors of the disease (such as immune factors or periodontal pathogens) may not be controlled adequately.

7.
J Adv Prosthodont ; 1(1): 10-8, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21165249

RESUMO

STATEMENT OF PROBLEM: Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions. PURPOSE: This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in early loading conditions. MATERIAL AND METHODS: A total of 36 solid screw implants (diameter 3.75 mm, length 10 mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium implants served as control. Gold crowns were inserted 4 weeks after implant placement and the dogs were immediately put on a food diet. Implants were observed for 10 weeks after loading. Radiographic assessments and stability tests were performed at the time of fixture installation, 2(nd) stage surgery, 4 weeks after loading, and 10 weeks after loading. Histological observations and morphometrical measurements were also performed. RESULTS: Of 36 implants, 33 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels (P = .46) and RFA values. The mean BIC% in the Mg-implants was 54.5 ± 8.4%. The mean BIC% in the turned implant was 45.3 ± 12.2%. These differences between the Mg-implant and control implant were statistically significant (P = .005). CONCLUSIONS: The anodized, Mg-incorporated implant demonstrated significantly more bone-to-implant contact (BIC) in early loading conditions. CLINICAL IMPLICATIONS: The results of this study in beagle dogs suggest the possibility of achieving predictable stability of early loaded free-standing dental implants with Mg-incorporated surface.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA