Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Langmuir ; 37(33): 10115-10125, 2021 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-34379427

RESUMO

The separation of plasma from blood cells in whole blood is an essential step for many diagnostic and therapeutic applications. However, the current point-of-care plasma separation approaches have not yet satisfied the need for a rapid, high-flux, and low-cost process. Here, we report a portable, low-cost, disposable membrane-based plasma separation device that enables rapid plasma extraction from whole blood. Rapid separation of plasma can be obtained with a simple three-step operation: blood injection, separation, and plasma collection. Our device benefits from the zwitterionic polyurethane-modified cellulose acetate (PCBU-CA) membrane, which can greatly inhibit the surface fouling of blood cells and membrane flux decline. The zwitterionic coating is stable on the membrane surface during blood filtration and leads to a 60% decrease in surface fibrinogen adsorption than a nonmodified membrane surface. The ultralow-blood-fouling properties of the PCBU-CA membrane enable rapid, continuous separation of plasma: within 10 min, the device can yield 0.5-0.7 mL of plasma from 10 mL of whole blood. The extracted plasma is verified as cell-free, exhibits a low hemoglobin level, and has a high protein recovery. Our PCBU-CA membrane provides a pathway for developing a high-efficiency portable plasma separation device that can reduce the time to diagnosis, allow effective patient care, and eventually reduce hospital costs.


Assuntos
Membranas Artificiais , Poliuretanos , Adsorção , Fibrinogênio , Humanos , Plasma
2.
Dev Comp Immunol ; 154: 105125, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38158145

RESUMO

Hirudo nipponia, a blood-sucking leech native to East Asia, possesses a rich repertoire of active ingredients in its saliva, showcasing significant medical potential due to its anticoagulant, anti-inflammatory, and antibacterial effects against human diseases. Despite previous studies on the transcriptomic and proteomic characteristics of leech saliva, which have identified medicinal compounds, our knowledge of tissue-specific transcriptomes and their spatial expression patterns remains incomplete. In this study, we conducted an extensive transcriptomic profiling of the salivary gland tissue in H. nipponia based on de novo assemblies of tissue-specific transcriptomes from the salivary gland, teeth, and general head region. Through gene ontology (GO) analysis and hierarchical clustering, we discovered a novel set of anti-coagulant factors-i.e., Hni-Antistasin, Hni-Ghilanten, Hni-Bdellin, Hni-Hirudin-as well as a previously unrecognized immune-related gene, Hni-GLIPR1 and uncharacterized salivary gland specific transcripts. By employing in situ hybridization, we provided the first visualization of gene expression sites within the salivary gland of H. nipponia. Our findings expand on our understanding of transcripts specifically expressed in the salivary gland of blood-sucking leeches, offering valuable resources for the exploration of previously unidentified substances with medicinal applications.


Assuntos
Hirudo medicinalis , Sanguessugas , Animais , Perfilação da Expressão Gênica , Hirudo medicinalis/genética , Hirudo medicinalis/metabolismo , Sanguessugas/genética , Sanguessugas/metabolismo , Proteínas de Membrana/genética , Proteínas de Neoplasias/genética , Proteínas do Tecido Nervoso/genética , Proteômica , Glândulas Salivares/metabolismo
3.
Sci Rep ; 13(1): 16646, 2023 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-37789071

RESUMO

Hand-foot-mouth disease (HFMD) is a viral disease that occurs primarily in children. Meteorological factors have a significant impact on its popularity annually in Korea. This study proposes a new HFMD prediction model using a dual-attention-based recurrent neural network (DA-RNN) and important weather factors for HFMD in Korea. First, suspected cases of HFMD in each state were predicted using meteorological factors from the DA-RNN. Second, the weather factors were divided into six categories: temperature, wind, rainfall, day length, humidity, and air pollution to conduct sensitivity analysis. Because of this prediction, the proposed model showed the best performance in predicting the number of suspected HFMD cases in a week compared with other RNN methods. Sensitivity analysis showed that air pollution and rainfall play an important role in HFMD in Korea. This model provides information for HFMD prevention and control and can be extended to predict other infectious diseases.


Assuntos
Doença de Mão, Pé e Boca , Criança , Humanos , Doença de Mão, Pé e Boca/diagnóstico , Doença de Mão, Pé e Boca/epidemiologia , Tempo (Meteorologia) , Conceitos Meteorológicos , Temperatura , Redes Neurais de Computação , República da Coreia/epidemiologia , China , Incidência
4.
World Neurosurg ; 171: e31-e37, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36528321

RESUMO

OBJECTIVE: We investigated the long-term effects of bone cement-augmented instrumentation in multilevel lumbar fusions in a retrospective cohort study. The use of cement-augmented screws is one of the techniques used to reduce early mechanical failure in treating multilevel lumbar fusion, especially in the elderly. However, little information is available regarding the long-term effects. METHODS: A total of 51 patients who had undergone ≥3 levels of lumbar fusion were divided into two groups according to the use of bone cement-augmented screw fixation involving the upper instrumented vertebra: 22 patients in the cement-augmented group (group I) and 29 patients in the non-cement-augmented group (group II). Analysis of radiographic adjacent disc segment degeneration (ASD) revealed patients with lumbosacral fusion with a similar degree of osteoporosis. Radiologic ASD was defined as progression of >2 UCLA (University of California, Los Angeles) grades at 2 years postoperatively. Other sagittal parameters and the preoperative magnetic resonance imaging Pfirrmann grades at the adjacent levels, possibly related to ASD, were also analyzed. RESULTS: No significant differences were present in the preoperative demographic and radiographic parameters between the 2 groups. However, the postoperative kyphotic changes at 3 months were greater for the non-cement-augmented group. In terms of the long-term effects, the incidence of radiologic ASD (group I, n = 20 [95.2%]; vs group II, n = 15 [53.6%]) was significantly higher in the cement-augmented group. Logistic regression analysis of radiologic ASD, including other clinical and radiologic parameters, postoperative pelvic incidence-lumbar lordosis mismatch (odds ratio, 5.201; 95% confidence interval, 1.123-24.090; P = 0.035), and cement augmentation (odds ratio, 20.193; 95% confidence interval, 2.195-185.729; P = 0.008) showed a significant correlation with the development of radiologic ASD at 2 years postoperatively. CONCLUSIONS: Although bone cement-augmented screw implantation can prevent kyphotic deformation at the proximal junction of upper instrumented vertebra in the early postoperative stages of multilevel lumbar fusion, a careful selection of patients is required because of possibly accelerated degeneration of adjacent segments.


Assuntos
Degeneração do Disco Intervertebral , Lordose , Fusão Vertebral , Humanos , Idoso , Cimentos Ósseos , Estudos Retrospectivos , Vértebras Lombares/cirurgia , Degeneração do Disco Intervertebral/cirurgia , Lordose/etiologia , Fusão Vertebral/métodos
5.
Biomater Sci ; 10(11): 2892-2906, 2022 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35446327

RESUMO

Thermoplastic elastomers are widely used in the medical industry for advanced medical and healthcare products, helping millions of patients achieve a better quality of life. Yet, microbial contamination and material-associated biofilms on devices remain a critical challenge because it is challenging for currently available materials to provide critical antifouling properties, thermoplasticity, and elastic properties simultaneously. We developed a highly flexible zwitterionic thermoplastic polyurethane with critical antifouling properties. A series of poly((diethanolamine ethyl acetate)-co-poly(tetrahydrofuran)-co-(1,6-diisocyanatohexane)) (PCB-PTHFUs) were synthesized. The PCB-PTHFUs exhibit a breaking strain of more than 400%, a high resistance to fibroblast cells for 24 h, and the excellent ability to prevent biofilm formation for up to three weeks. This study lays a foundation for clarifying the structure-function relationships of zwitterionic polymers. This thermoplastic PCB-PTHFU platform, with its unmatched antifouling properties and high elasticity, has potential for implanted medical devices and a broad spectrum of applications that suffer from biofouling, such as material-associated infection.


Assuntos
Incrustação Biológica , Elastômeros , Incrustação Biológica/prevenção & controle , Humanos , Polímeros , Poliuretanos/farmacologia , Qualidade de Vida
6.
World Neurosurg ; 127: 249-252, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30980972

RESUMO

BACKGROUND: As the prevalence of spinal fusion surgery has increased, reliable and safe bone graft substitutes have been developed in response. Biocompatible osteoconductive polymer (BOP) has been used as a bone graft alternative for spine surgery. We present a case of cervical myelopathy due to extrusion of BOP 23 years after surgery and discuss the pathophysiology in terms of spinal fusion. CASE DESCRIPTION: A 65-year-old man presented with a 3-month history of cervical myelopathic symptoms. Twenty-three years earlier, the patient had undergone cervical surgery for a C6-7 herniated disc with the use of BOP. Imaging studies of the cervical spine showed cord compression due to extruded BOP at C6-7. He underwent corpectomy of the C7 vertebral body and removal of the BOP for the neural decompression, combined with interbody fusion by use of an iliac bone graft and plate fixation. During the operation, crumbly fibers of the BOP were easily removed. His myelopathic symptoms improved immediately after surgery. Postoperative magnetic resonance imaging also showed successful decompression of the spinal cord. Histologically, a foreign body reaction and bony degeneration were found around the synthetic fibers of the BOP. CONCLUSIONS: Spine surgeons should recognize the pathophysiology of the BOP used for spine fusion surgery. Although BOP is not currently used for spinal surgery, patients undergoing previous surgery with the BOP can present with related complications. Revision surgery is recommended to remove the unincorporated BOP and achieve solid spine fusion.


Assuntos
Metilmetacrilatos , Complicações Pós-Operatórias , Povidona , Doenças da Medula Espinal/etiologia , Fusão Vertebral , Idoso , Medula Cervical , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/patologia , Vértebras Cervicais/cirurgia , Humanos , Masculino , Complicações Pós-Operatórias/cirurgia , Doenças da Medula Espinal/diagnóstico por imagem , Doenças da Medula Espinal/patologia , Doenças da Medula Espinal/cirurgia
7.
Nano Lett ; 7(9): 2806-11, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17685662

RESUMO

We present a simple, fast, and practical route to vertically align carbon nanotubes on a porous support using a combination of self-assembly and filtration methods. The advantage of this approach is that it can be easily scaled up to large surface areas, allowing the fabrication of membranes for practical gas separation applications. The gas transport properties of thus constructed nanotube/polymer nanocomposite membranes are analogous to those of carbon nanotube membranes grown by chemical vapor deposition. This paper shows the first data for transport of gas mixtures through carbon nanotube membranes. The permeation of gas mixtures through the membranes exhibits different properties than those observed using single-gas experiments, confirming that non-Knudsen transport occurs.


Assuntos
Cristalização/métodos , Análise de Injeção de Fluxo/métodos , Gases/química , Membranas Artificiais , Nanotecnologia/métodos , Nanotubos de Carbono/química , Politetrafluoretileno/química , Difusão , Substâncias Macromoleculares/química , Teste de Materiais , Microfluídica/métodos , Conformação Molecular , Nanotubos de Carbono/ultraestrutura , Tamanho da Partícula , Porosidade , Propriedades de Superfície
8.
Proteomics ; 4(11): 3527-35, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15529409

RESUMO

Different proteins are found in lipid rafts depending on the isolation method. For example, insulin receptor was predominantly found in lipid raft fractions prepared from HepG2 cells with Brij 35, but were not present in lipid rafts isolated with Triton X-100. In order to assess the effect of detergent type and temperature on raft isolation, raft proteins from HepG2 cells were analyzed by two-dimensional (2-D) electrophoresis. More raft protein spots appeared when rafts were isolated by Brij 35 than by Triton X-100. In addition, more raft proteins were found when isolated at 37 degrees C than at 4 degrees C, indicating that lipid rafts are much more stable at physiological temperature (37 degrees C) in the presence of detergents. Indeed, lipid-modified proteins, such as Src and Lyn, were found in raft fractions even when detergent-resistant rafts were isolated at room or physiological temperature. The 2-D gel profile of raft proteins isolated with detergent-free (high-pH/carbonate) method was considerably similar to that of detergent-resistant raft proteins but contained a greater number of distinct protein spots. Whereas many detergent-resistant raft proteins disappeared upon cellular exposure to methyl-beta-cyclodextrin, high pH/carbonate-resistant raft proteins did not, suggesting that many of proteins isolated by high pH/carbonate could be contaminants. Considering these data, we conclude that liquid-ordered state of detergent-resistant lipid rafts is not destroyed at physiological temperature.


Assuntos
Microdomínios da Membrana/metabolismo , Proteínas de Membrana/metabolismo , Eletroforese em Gel Bidimensional , Humanos , Octoxinol , Polidocanol , Polietilenoglicóis , Receptor de Insulina/fisiologia , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA