Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Int J Mol Sci ; 24(18)2023 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-37762262

RESUMO

Symptoms of oral discomfort such as dry mouth are common in older people wearing dentures. Such symptoms are mainly treated symptomatically. Many of these symptoms are related to saliva, and associations with salivary volume have been reported. Although denture treatment improves symptoms by increasing the amount of saliva, the effects on salivary components remain unclear. This study aimed to investigate the effects of denture treatment on salivary metabolite changes based on salivary metabolome analyses. We enrolled 21 patients requiring denture treatment. At the first visit, and after completion of denture treatment, saliva outflow was measured under resting and stimulated conditions, samples for salivary metabolite analysis were collected, and masticatory efficiency was tested. In all participants, masticatory efficiency increased after denture treatment. Moreover, the amounts of resting and stimulated saliva were increased. Using salivary metabolome analysis, 61 salivary metabolites were detected. Substantial concentration changes were observed for 4 and 21 metabolites in resting and stimulated saliva, respectively. The four metabolites common to both saliva tests had significantly lower concentrations after treatment. These results suggest that the improvement in masticatory function by dentures is related not only to salivary secretion volume, but also to salivary metabolite composition.


Assuntos
Metaboloma , Descanso , Humanos , Idoso , Projetos Piloto , Saliva , Dentaduras
2.
Psychogeriatrics ; 23(1): 23-31, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36273804

RESUMO

BACKGROUND: The number of patients with dementia is increasing worldwide. Modifying risk factors may significantly reduce the prevalence and cost of dementia. The number of remaining teeth, occlusal force, denture use, and periodontal disease status are associated with the risk of developing dementia. The oral environment may be a risk factor for dementia. This study aimed to investigate the association between the oral environment and cerebral blood flow in patients with mild cognitive impairment and dementia (either Alzheimer type dementia (ATD) or dementia with Lewy bodies (DLB)). We aimed to identify differences in the oral environment according to the underlying neurodegenerative disease. METHODS: The participants were 25 patients with ATD and 25 patients with DLB who visited the Department of Dementia and Geriatric Medicine, Kanagawa Dental University Hospital. Patients were diagnosed with ATD and DLB by well-trained specialists certified by the Japanese Dementia Society and categorised as Level 3 or 4 by the Functional Assessment Staging of Alzheimer Disease scale. The correlation between oral environment (number of teeth, periodontal tissue, and oral function) and cerebral blood flow in each brain area calculated by single photon emission computed tomography was examined. RESULTS: The DLB group showed a significant correlation between masticatory performance and cerebral blood flow in some areas, while no such correlation was observed in the ATD group. Significant correlations were found between periodontal pocket depth and bleeding on probing and cerebral blood flow in some areas in both groups, although the correlation was considerable in the ATD group. CONCLUSIONS: The results of this study suggest that the association between changes in the oral environment and cerebral blood flow may differ among patients with ATD and DLB, depending on the underlying causative disease.


Assuntos
Doença de Alzheimer , Doença por Corpos de Lewy , Doenças Neurodegenerativas , Humanos , Idoso , Encéfalo , Circulação Cerebrovascular/fisiologia
3.
BMC Oral Health ; 21(1): 464, 2021 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-34556111

RESUMO

BACKGROUND: The use of intraoral scanners (IOS) has facilitated the use of digital workflows for the fabrication of implant-supported prostheses not only for single missing teeth, but also for multiple missing teeth. However, the clinical application of IOS and computer-aided design/manufacturing (CAD/CAM) in implant-supported prosthodontics remains unclear. This study aimed to compare the accuracy of digital and silicone impressions for single-tooth implants for bounded edentulous spaces and two-unit and three-unit implant-supported fixed dental prostheses for free-end edentulous spaces. METHODS: This study enrolled 30 patients (n = 10 for each of the three groups) with an average age of 61.9 years. Conventional silicone-based and digital IOS-based impressions were made for all patients, and the implant superstructures were fabricated. We measured the scan-body misfit and compared the accuracy of the impressions for single-unit, two-unit, and three-unit implant prostheses with a bounded edentulous space by superimposing the standard triangulated language (STL) data obtained from IOS over the STL data of the plaster model used for final prosthesis fabrication. The scan bodies of the superimposed single-molar implant, two-unit implant prosthesis without teeth on the mesial side, two-unit implant prosthesis without teeth on the distal side, three-unit implant prosthesis without teeth on the mesial side, and three-unit implant prosthesis without teeth on the distal side were designated as A, B1, B2, C1, and C2, respectively. The misfit for each scan body was calculated and the accuracies were compared using the Tukey-Kramer method. RESULTS: The average scan-body misfit for conditions A, B1, B2, C1, and C2 was 40.5 ± 18.9, 45.4 ± 13.4, 56.5 ± 9.6, 50.7 ± 14.9, and 80.3 ± 12.4 µm, respectively. Significant differences were observed between the accuracies of A and B2, A and C2, and C1 and C2 (P < 0.001). CONCLUSIONS: IOS and CAD/CAM can find clinical applications for implant-supported prostheses of up to three units for a bounded edentulous saddle. The use of IOS could render implant treatment easier, benefiting both the surgeons and patients. Prosthesis maladjustment may lead to peri-implantitis and prosthetic fracture. Therefore, further validation of the accuracy of IOS impressions is required in patients with multiple missing teeth in long-span implant prostheses.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Boca Edêntula , Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Prótese Dentária Fixada por Implante , Humanos , Pessoa de Meia-Idade , Silicones
4.
Implant Dent ; 25(1): 47-53, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26397477

RESUMO

OBJECTIVE: The objective of this study was to investigate morphologically the progression of periimplantitis around an ultraviolet (UV)-light-irradiated implant in dogs. MATERIALS AND METHODS: Pure titanium implants (3.3 mm in diameter and 8 mm long) were placed into dog jawbone bilaterally. Implants on one side were irradiated with UV light for 15 minutes using a photodevice immediately before placement (UV group), whereas those on the other side were not irradiated (non-UV group). Osseointegration was confirmed 90 days after implant placement by radiography. Experimental periimplantitis was induced by the application of dental floss over 90 days. Clinical and radiographic examination and micro-computed tomography (micro-CT) were performed after 90 and 180 days, and bone resorption was measured. The bone-implant interface in tissue sections was examined by light microscopy. RESULTS: Bone resorption around the UV-irradiated implant was less pronounced than around the non-UV-irradiated implant in the ligature-induced periimplantitis model. Tissue section images revealed no contact and partial destruction at the bone-implant interface. CONCLUSION: Within the limitations of this preliminary investigation, it is suggested that UV-light-irradiated implants suppress spontaneous progression of periimplantitis.


Assuntos
Peri-Implantite/prevenção & controle , Terapia Ultravioleta , Animais , Implantação Dentária Endóssea/efeitos adversos , Implantação Dentária Endóssea/métodos , Cães , Feminino , Peri-Implantite/diagnóstico por imagem , Projetos Piloto , Radiografia Dentária , Terapia Ultravioleta/métodos , Microtomografia por Raio-X
5.
BMC Neurosci ; 15: 4, 2014 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-24387332

RESUMO

BACKGROUND: Using senescence-accelerated mouse prone 8 (SAMP8), we examined whether reduced mastication from a young age affects hippocampal-dependent cognitive function. We anesthetized male SAMP8 mice at 8 weeks of age and extracted all maxillary molar teeth of half the animals. The other animals were treated similarly, except that molar teeth were not extracted. At 12 and 24 weeks of age, their general behavior and their ability to recognize novel objects were tested using the open-field test (OFT) and the object-recognition test (ORT), respectively. RESULTS: The body weight of molarless mice was reduced significantly compared to that of molar-intact mice after the extraction and did not recover to the weight of age-matched molar-intact mice throughout the experimental period. At 12 weeks of age, molarless mice showed significantly greater locomotor activity in the OFT than molar-intact mice. However, the ability of molarless mice to discriminate a novel object in the ORT was impaired compared to that of molar-intact mice. The ability of both molarless and molar-intact SAMP8 mice to recognize objects was impaired at 24 weeks of age. These results suggest that molarless SAMP8 mice develop a deficit of cognitive function earlier than molar-intact SAMP8 mice. Interestingly, both at 12 and 24 weeks of age, molarless mice showed a lateralized preference of object location in the encoding session of the ORT, in which two identical objects were presented. Their lateralized preference of object location was positively correlated with the rightward turning-direction preference, which reached statistical significance at 24 weeks of age. CONCLUSIONS: Loss of masticatory function in early life causes malnutrition and chronic stress and impairs the ability to recognize novel objects. Hyperactivation and lateralized rotational behavior are commonly observed with dysfunction of the dopaminergic system, therefore, reduced masticatory function may deplete the mesolimbic and mesocorticolimbic dopaminergic systems to impair the cognitive functions of selective attention and recognition memory in the prefrontal cortex and the hippocampus.


Assuntos
Comportamento Animal , Transtornos da Alimentação e da Ingestão de Alimentos/fisiopatologia , Lateralidade Funcional , Hipocampo/fisiopatologia , Mastigação , Transtornos da Memória/fisiopatologia , Reconhecimento Psicológico , Animais , Transtornos da Alimentação e da Ingestão de Alimentos/complicações , Masculino , Transtornos da Memória/etiologia , Camundongos , Dente Molar/cirurgia , Estresse Psicológico/etiologia , Estresse Psicológico/fisiopatologia , Extração Dentária
6.
Gerodontology ; 31(1): 68-75, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23581545

RESUMO

OBJECTIVES: Specific materials when used in the manufacture of dentures can enhance the elimination of micro-organisms to promote oral hygiene. We used Candida albicans adhesion assays, methylene blue (MB)-decomposition tests and mechanical property tests to evaluate the photocatalytic properties of acrylic resin containing fluoridated apatite-coated titanium dioxide (FAp-TiO2 ) after treatment with ultraviolet A (UVA) irradiation. BACKGROUND: Conventional denture cleaning methods are unable to completely eliminate micro-organisms from dentures. MATERIALS AND METHODS: Test specimens were prepared using acrylic resin containing three types of TiO2 powder [FAp-TiO2, titanium dioxide (TiO2 ) and hydroxyapatite-coated TiO2 (HAp-TiO2 )]; n = 96. In the adhesion assay, test specimens were incubated in a fungal suspension and subjected to UVA irradiation, and the number of attachments of C. albicans on the test specimens was counted. The MB-decomposition test and the three-point bending test were then performed to assess the photocatalytic effects of the FAp-TiO2 -containing acrylic resin. RESULTS: Fluoridated apatite-coated titanium dioxide-containing acrylic resin demonstrated superior effectiveness in inhibiting C. albicans adherence as well as in decomposing MB. In the three-point bending test, the resin showed a smaller decrease in flexural strength compared with TiO2 - or HAp-TiO2 -containing acrylic resin. Furthermore, UVA irradiation for 360 h did not significantly influence its flexural strength or elasticity modulus as compared with the control; this fulfils the requirements of International Organization for Standardization 1567:1999. CONCLUSION: Fluoridated apatite-coated titanium dioxide-containing acrylic resin is a clinically suitable material that promotes proper denture hygiene, particularly for elderly persons requiring nursing care or who have a decreased ability to perform normal activities of daily living.


Assuntos
Resinas Acrílicas/química , Materiais Revestidos Biocompatíveis/química , Materiais Dentários/química , Bases de Dentadura , Titânio/química , Apatitas/química , Apatitas/farmacologia , Candida albicans/efeitos dos fármacos , Candida albicans/fisiologia , Catálise , Bases de Dentadura/microbiologia , Durapatita/química , Módulo de Elasticidade , Humanos , Azul de Metileno/química , Oxidantes/química , Oxidantes/farmacologia , Fotólise , Maleabilidade , Estresse Mecânico , Propriedades de Superfície , Titânio/farmacologia , Raios Ultravioleta
7.
J Prosthodont Res ; 68(1): 132-138, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-37316261

RESUMO

PURPOSE: The purpose of this study is to investigate the effects of denture adhesives on masticatory performance via a 10-center, parallel, randomized, controlled trial of complete denture wearers in Japan. METHODS: The trial was conducted between September 2013 and October 2016. The inclusion criteria were complete edentulism, willingness to undergo new complete denture treatment, and willingness to return for recall treatment. The exclusion criteria were age 90 years or older, presence of severe systemic illness, inability to understand the questionnaires, wearing metal base complete dentures, denture adhesive user, wearing prosthetics for maxillofacial defects, wearing complete dentures with tissue conditioners, and severe xerostomia. Randomization of the powder-type denture adhesive (powder), cream-type denture adhesive (cream), and control (saline) groups was performed using a sealed envelope system. Masticatory performance was measured using color-changeable chewing gum. Intervention blinding was not feasible. RESULTS: Sixty-seven control, 69 powder, and 64 cream participants are analyzed using the intention-to-treat principle. The participants in all groups show significantly improved masticatory performance at post-intervention (paired t-test with Bonferroni correction P < 0.0001). However, no significant difference in masticatory performance is detected among the three groups (one-way analysis of variance). A significant negative correlation between pre- and post-changes in masticatory performance and intraoral condition scores is observed (Pearson's correlation coefficient, P < 0.0001). CONCLUSIONS: Although denture adhesives improved the masticatory performance of complete denture wearers, their clinical effects are comparable to those of saline solution. The use of denture adhesives is more effective in complete denture wearers with unsatisfactory intraoral conditions.


Assuntos
Boca Edêntula , Perda de Dente , Humanos , Idoso de 80 Anos ou mais , Pós , Prótese Total , Goma de Mascar , Mastigação
8.
Gerodontology ; 30(3): 187-93, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22607455

RESUMO

OBJECTIVE: The purpose of this long-term randomised controlled trial was to compare the longevity of dentures constructed using a conventional acrylic resin (CAR) to that of dentures constructed using an acrylic-based resilient liner (ARL). MATERIALS AND METHODS: The follow-up study was essentially carried out by annual telephone calls to each of the 67 participants. The Kaplan-Meier method and life-table analysis were used for univariate analyses. The Cox proportional-hazards test was used as a final model for statistically adjusting predictor variables such as sex, clinician type, mandibular denture type and age at denture delivery. RESULTS: The denture type was likely to affect the survival time of the dentures, while the sex and clinician type were not. The group using acrylic-based resilient denture liners had twice the risk of having shorter denture-survival times than those using conventional acrylic resin dentures. Younger participants were likely to have a reduced risk of having shorter denture-survival times than older participants. CONCLUSION: We conclude that mandibular complete dentures constructed using ARL are twice as likely as dentures constructed using CAR to have shorter denture survival times, mainly because of material deterioration.


Assuntos
Resinas Acrílicas/química , Materiais Dentários/química , Reembasadores de Dentadura/estatística & dados numéricos , Prótese Total Inferior/estatística & dados numéricos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Falha de Restauração Dentária/estatística & dados numéricos , Planejamento de Dentadura/estatística & dados numéricos , Feminino , Seguimentos , Humanos , Tábuas de Vida , Estudos Longitudinais , Masculino , Modelos de Riscos Proporcionais , Fatores Sexuais , Análise de Sobrevida
9.
Materials (Basel) ; 16(7)2023 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-37048914

RESUMO

Based on the hypothesis that the fabrication of dental models using fused deposition modeling and poly-lactic acid (PLA), followed by recycling and reusing, would reduce industrial waste, we aimed to compare the accuracies of virgin and recycled PLA models. The PLA models were recycled using a crusher and a filament-manufacturing machine. Virgin PLA was labeled R, and the first, second, and third recycles were labeled R1, R2, and R3, respectively. To determine the accuracies of the virgin and reused PLA models, identical provisional crowns were fitted, and marginal fits were obtained using micro-computed tomography. A marginal fit of 120 µm was deemed acceptable based on previous literature. The mesial, distal, buccal, and palatal centers were set at M, D, B, and P, respectively. The mean value of each measurement point was considered as the result. When comparing the accuracies of R and R1, R2, and R3, significant differences were noted between R and R3 at B, R and R2, R3 at P, and R and R3 at D (p < 0.05). No significant difference was observed at M. This study demonstrates that PLA can be recycled only once owing to accuracy limitations.

10.
J Prosthodont Res ; 67(1): 144-149, 2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-35466158

RESUMO

Purpose We considered the possibility of reducing industrial waste by fabricating and reusing dental models prepared using a fused deposition modeling (FDM) 3D printer and polylactic acid (PLA) filaments. The purpose of this study was to verify the accuracy of models fabricated using FDM and PLA.Methods The same provisional crown was used to check the marginal fit on PLA models prepared using an intraoral scanner (IOS) and FDM, plaster models made with silicone impression material and plaster, and resin models prepared using an IOS and stereolithography apparatus (SLA) 3D printer. The marginal fit was measured using micro-computed tomography at four points on the tooth: the buccal center (B), palatal center (P), mesial center (M), and distal center (D) points.Results At point B, the marginal gaps were 118 ± 21.7, 62 ± 16.4, and 50 ± 26.5 µm for the PLA, resin, and plaster models, respectively, with a significant difference between the PLA model and the other two. However, the marginal gap at all other measurement points was not significantly different between the models (P > 0.05).Conclusions We compared the accuracy of the models fabricated using the FDM, SLA, and conventional methods. The combination of FDM and PLA filaments showed no significant differences from the other models, except at point B, indicating its usefulness. Therefore, FDM and PLA may become necessary materials for dental treatment in the future.


Assuntos
Desenho Assistido por Computador , Modelos Dentários , Microtomografia por Raio-X , Impressão Tridimensional , Poliésteres , Coroas
11.
J Prosthodont Res ; 67(4): 548-555, 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-36740264

RESUMO

PURPOSE: This study aimed to determine the effects of denture adhesives on denture retention and occlusal force in complete denture wearers in a multicenter, randomized, parallel-group controlled trial. METHODS: Two hundred edentulous patients wearing complete dentures were allocated to three groups: powder-type denture adhesive, cream-type denture adhesive, and control (saline solution). Denture adhesives and saline solution were applied to the dentures for 4 days. The retentive force of the dentures and occlusal force were measured using a force transducer occlusal force meter at baseline and after 4 days of intervention. In addition to between-group comparisons, subgroup analyses of denture retention and occlusal force were performed based on the level of difficulty of the edentulism treatment. The levels were ranked as I (easy), II, III, and IV (difficult). RESULTS: Cream-type denture adhesives significantly improved the retentive force of the dentures (P<0.01) and occlusal force (P<0.05), with no significant differences between baseline and post-intervention forces in the powder-type denture adhesive and control groups. In within-group comparisons, cream-type denture adhesives improved both the retentive and occlusal forces at Level II (P<0.05), and powder-type denture adhesives improved the occlusal force at Level II (P<0.01). CONCLUSIONS: Application of cream-type denture adhesives effectively improves the denture retention and occlusal force in complete denture wearers with a moderate degree of difficulty during edentulism treatment.

12.
Dent Mater J ; 41(3): 414-420, 2022 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35135942

RESUMO

Since cast titanium prostheses have many drawbacks, multi-directionally forged titanium grade 2 (MDF) was developed, and the application of the milling process was proposed for improving the titanium clasp. This in vitro study evaluated milled titanium clasps, including MDF titanium. Milling clasps were manufactured with commercially pure (CP) titanium grade 2 (CP 2), grade 4 (CP 4), Ti-6-Al-4V, and MDF. As a control, a CP 2 cast titanium clasp was fabricated in the conventional manner. No porosities and catastrophic failures were observed in the four milled titanium clasps. Fitness accuracy and retentive forces of milled CP 2 and CP 4 tended to be worse, and the milled MDF showed the higher retentive forces (12.45 N) than did cast and milled CP 2 clasps (9.32 N and 4.42 N). Milled titanium clasps can be recommended for longer-term clinical use as compared to cast clasps.


Assuntos
Grampos Dentários , Prótese Parcial Removível , Ligas de Cromo , Retenção de Dentadura , Porosidade , Titânio
13.
Dent Mater J ; 41(3): 459-465, 2022 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35249904

RESUMO

Pure titanium is widely used as a material in dental implants. However, it possesses inferior mechanical strength. This study aimed to elucidate the efficacy of acid treated multi-directionally forged (MDF) pure titanium in vivo. We verified the temporal changes until osseointegration in beagle dogs. Using two types of experimental materials (conventional pure titanium or MDF pure titanium), new bone formation was assessed using morphological examinations, and the bone-to-implant contact (BIC) value was evaluated at each time point (14, 30, and 90 days after the operation). As such, new bone formation was observed around the acid-etched MDF group, in which the BIC value was highest, followed by that in the acid-etched pure titanium group. MDF pure titanium implants showed early promotion of new bone formation compared to conventional titanium implants. The new acid-treated MDF made of pure titanium could be applied to humans in the future to prove its practicality.


Assuntos
Implantes Dentários , Titânio , Animais , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Cães , Implantes Experimentais , Osseointegração , Propriedades de Superfície
14.
J Prosthodont Res ; 66(4): 623-629, 2022 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-35082225

RESUMO

PURPOSE: Evidence regarding the performance of digital dentures (DDs) fabricated using 3D printing is insufficient. This study aimed to evaluate patient satisfaction with conventional dentures (CDs) and DDs fabricated using 3D printing. METHODS: This randomized controlled trial was conducted between November 2017 and May 2020. In the CD-DD group, CDs were fabricated before DDs, while the protocol was reversed in the DD-CD group. The primary outcome was patient satisfaction, quantified using a 100-mm visual analog scale, which assessed chewing efficiency, pain, stability, retention, comfort, esthetics, ease of cleaning, phonetics, and general satisfaction. Secondary outcomes were quality of life (QOL), number of visits, time required for definitive denture fabrication, number of adjustment appointments, and time required for denture stabilization after denture delivery. RESULTS: Patient satisfaction with CDs was superior in terms of phonetics, ease of cleaning, stability, comfort, and general satisfaction. Secondary outcomes such as social disability and the number of clinic visits were significantly lower in patients with DDs. However, the two groups showed no significant differences in the other outcomes. Although patient satisfaction with DDs was inferior to that with CDs, 20% of patients preferred and used DDs (12 patients preferred CDs, and three patients opted for DDs). CONCLUSION: Although patient satisfaction or QOL with DDs may be somewhat inferior to that with CDs, 20% of patients preferred and used DDs daily. Thus, DDs fabricated using 3D printing may have comparable practicality and efficacy to CDs.


Assuntos
Prótese Total , Satisfação do Paciente , Estudos Cross-Over , Humanos , Impressão Tridimensional , Qualidade de Vida
15.
Trials ; 23(1): 738, 2022 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-36056410

RESUMO

BACKGROUND: During restoration of poorly fitting complete dentures (CDs) in edentulous patients, liners are used to reconstruct the concave surfaces of CDs with a new base material. These relining materials are classified into resilient liners (RLs) and non-resilient liners (NRLs), but the clinical effects of these liners and their selection criteria remain unclear. The purpose of this study is to evaluate the clinical efficacy of relining mandibular CDs using RL and NRL and to conduct a follow-up study. METHODS: The study is currently being conducted at eight centers, and a parallel-group randomized controlled trial (RCT) is underway. One hundred thirty-two edentulous patients with poorly fitting mandibular CDs will be assigned to two groups based on whether they will receive RL or NRL. Participants will have an RL or NRL applied for relining their CDs using an indirect method of dynamic impressions. Data will be recorded at 1 week and 3, 6, and 12 months after denture delivery. The primary outcome will be assessment of the patients' general satisfaction by using a 100-mm visual analog scale (VAS). Secondary outcomes will be measured as patient-reported outcomes, including food intake status and oral hygiene-related quality of life. Masticatory performance and the number of sore spots on the oral mucosa will also be recorded. Comparisons between the two groups and within-subject comparisons of pre- and post-intervention measurements will be conducted. DISCUSSION: For dentists and prosthetic researchers in Japan, this RCT will provide information on the clinical efficacy of RL materials in comparison to RNL in CD wearers. The new evidence regarding the use of RL materials in an aging population will also be useful to dentists in other countries in their routine clinical practice. TRIAL REGISTRATION: This clinical trial has been registered at the University Hospital Medical Information Network (UMIN) Center (UMIN000041950).


Assuntos
Prótese Total , Boca Edêntula , Idoso , Humanos , Mandíbula/cirurgia , Boca Edêntula/cirurgia , Estudos Multicêntricos como Assunto , Satisfação do Paciente , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
16.
J Clin Med ; 10(4)2021 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-33671369

RESUMO

The major causes of oral candidiasis include decreased salivary flow rate and the use of ill-fitting dentures. However, the relationships among prosthetic treatment, saliva, and Candida albicans have not been elucidated. This study aimed to examine the effects of prosthetic treatment and changes in saliva (mainly the salivary flow rate) on oral candidiasis symptoms. Participants requiring prosthetic treatment underwent testing for C. albicans, salivary flow rate, intraoral symptoms, and bite force at the initial visit and four months after treatment to evaluate pretreatment and post-treatment changes. The relationships among C. albicans, salivary flow rate, dentures, and intraoral symptoms were analyzed using multiple regression analysis. Denture treatment improved activity against C. albicans as well as the salivary flow rate, intraoral symptoms, and masticatory function. Multiple regression analysis revealed that changes in the stimulated salivary flow rate due to prosthetic treatment significantly improved C. albicans detection (p = 0.011), intraoral symptoms (p = 0.037), and bite force (p = 0.031). This study showed that prosthetic treatment improved salivary flow and intraoral symptoms and confirmed the influence of stimulated salivary flow rate changes.

17.
Int J Implant Dent ; 7(1): 2, 2021 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-33432526

RESUMO

BACKGROUND: Implant treatment using guided surgery is becoming widespread in clinical dental practice. Furthermore, the development of digital technology has enabled the use of intraoral scanners (IOSs) to fabricate surgical guide plates. The objective of this study was to compare the accuracy of guided surgery using the silicone impression method with a three-dimensional (3D) scanner and the digital impression method with IOS for one side of the mandibular free end. In addition, we compared the accuracy of tooth-supported vs tooth/mucosa-supported surgical guide plates. RESULTS: The accuracy of the tooth-supported surgical guide plate using the new IOS method instead of the method of obtaining impressions with conventional silicone resulted in better measurements of 3D deviation at the crest, 3D deviation at the apex, and angular deviation. In terms of the accuracy of the tooth/mucosa-supported surgical guide plate, there were no significant differences in all measurements. The surgical guide plate using an IOS and the tooth/mucosa-supported surgical guide plate may enable more accurate guided surgery. CONCLUSION: Tooth/mucosa-supported guided surgery involving preparation with an IOS may result in more accurate implant surgery.


Assuntos
Desenho Assistido por Computador , Silício , Placas Ósseas , Mandíbula/diagnóstico por imagem , Silicones
18.
Dent Mater J ; 40(4): 1049-1054, 2021 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-33883352

RESUMO

Titanium are often used as dental materials, pure titanium present low strength and titanium alloy is reported poor biocompatibility, respectively. To overcome the problem, we fabricated high-strength multi-directional forged (MDF) titanium with improved mechanical properties without changing the chemical composition and evaluated its applicability in prosthetic crowns. Cutting tests: the average absolute value of the difference before and after cutting was calculated as the uncut amount. Surface evaluations: MDF titanium, pure titanium, and the Ti-6Al-4V alloy were the surface properties (the surface roughness, the contact angles, glossiness) of the samples were evaluated. The fitness test used digital data. These demonstrated that the good workability of high-strength MDF titanium. The surface-roughness and contact-angle properties of MDF titanium and pure titanium were similar. The fitness test showed no significant differences between MDF titanium and pure titanium crowns. These results suggest that MDF titanium is promising for fabricating prosthetic crowns in dental applications.


Assuntos
Ligas Dentárias , Titânio , Desenho Assistido por Computador , Coroas , Teste de Materiais , Propriedades de Superfície
19.
J Prosthodont Res ; 65(3): 353-359, 2021 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-33116029

RESUMO

Purpose To investigate the difference in improvement of oral health-related quality of life (OHR-QoL) depending on the oral and denture conditions of a complete denture wearer when using a cream or powder type denture adhesive in a 10-center parallel randomized clinical trial.Methods Two hundred edentulous subjects who wore complete dentures were allocated to each of the three groups according to denture adhesive type: cream, powder, and control (saline solution). The materials were applied to the mucosal surface of the dentures for 4 days, and baseline data and data after the intervention were collected. OHR-QoL was assessed using the Japanese version of the modified Oral Health Impact Profile for Edentulous Patients (OHIP-EDENT-J) scale for outcome. Multivariate analysis was used to investigate improvements in OHR-QoL according to participant characteristics among complete denture wearers using these materials.Results OHIP-EDENT-J scores were significantly decreased in all groups after the intervention (p < 0.05); however, there were no statistically significant differences among the groups. Multiple logistic regression analysis revealed a significant association between the vertical height of the maxillary and mandibular alveolar ridge and OHIP-EDENT-J scores in the cream-type denture adhesive group. In contrast, there were no significant association between participant characteristics and OHIP-EDENT-J scores in the powder-type adhesive and control groups.Conclusions The use of denture adhesives could improve OHR-QoL for complete denture wearers. The cream-type denture adhesives may be expected to improve OHR-QoL in patients with poor residual ridge conditions compared with patients with good residual ridge conditions.


Assuntos
Boca Edêntula , Qualidade de Vida , Prótese Total , Humanos , Análise Multivariada , Saúde Bucal , Satisfação do Paciente , Inquéritos e Questionários
20.
Int J Oral Maxillofac Implants ; 25(1): 49-62, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20209187

RESUMO

PURPOSE: To examine the bioactivity of differently aged titanium (Ti) disks and to determine whether ultraviolet (UV) light treatment reverses the possible adverse effects of Ti aging. MATERIALS AND METHODS: Ti disks with three different surface topographies were prepared: machined, acid-etched, and sandblasted. The disks were divided into three groups: disks tested for biologic capacity immediately after processing (fresh surfaces), disks stored under dark ambient conditions for 4 weeks, and disks stored for 4 weeks and treated with UV light. The protein adsorption capacity of Ti was examined using albumin and fibronectin. Cell attraction to Ti was evaluated by examining migration, attachment, and spreading behaviors of human osteoblasts on Ti disks. Osteoblast differentiation was evaluated by examining alkaline phosphatase activity, the expression of bone-related genes, and mineralized nodule area in the culture. RESULTS: Four-week-old Ti disks showed = or < 50% protein adsorption after 6 hours of incubation compared with fresh disks, regardless of surface topography. Total protein adsorption for 4-week-old surfaces did not reach the level of fresh surfaces, even after 24 hours of incubation. Fifty percent fewer human osteoblasts migrated and attached to 4-week-old surfaces compared with fresh surfaces. Alkaline phosphatase activity, gene expression, and mineralized nodule area were substantially reduced on the 4-week-old surfaces. The reduction of these biologic parameters was associated with the conversion of Ti disks from superhydrophilicity to hydrophobicity during storage for 4 weeks. UV-treated 4-week-old disks showed even higher protein adsorption, osteoblast migration, attachment, differentiation, and mineralization than fresh surfaces, and were associated with regenerated superhydrophilicity. CONCLUSIONS: Time-related degradation of Ti bioactivity is substantial and impairs the recruitment and function of human osteoblasts as compared to freshly prepared Ti surfaces, suggesting a "biologic aging"-like change of Ti. UV treatment of aged Ti, however, restores and even enhances bioactivity, exceeding its innate levels.


Assuntos
Materiais Biocompatíveis , Osteoblastos/citologia , Titânio/química , Titânio/efeitos da radiação , Raios Ultravioleta , Adsorção/efeitos da radiação , Animais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/efeitos da radiação , Bovinos , Adesão Celular , Movimento Celular , Células Cultivadas , Fibronectinas/química , Humanos , Osseointegração , Osteoblastos/metabolismo , Osteoblastos/fisiologia , Osteocalcina/biossíntese , Osteopontina/biossíntese , Albumina Sérica/química , Propriedades de Superfície , Fatores de Tempo , Molhabilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA