Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Catheter Cardiovasc Interv ; 96(2): E129-E141, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31714010

RESUMO

OBJECTIVES: The aim of this study was to evaluate the long-term clinical safety and efficacy of drug-coated balloon (DCB) in the treatment of in-stent restenosis (ISR). BACKGROUND: There is a long-term safety issue in peripheral arterial disease patients treated with paclitaxel-coated balloon, this has also raised concerns on DCB in coronary intervention. METHODS: Nine randomized controlled trials (RCTs) and nine observational studies (OSs) were included with a total of 3,782 patients (1,827 in the DCB group, 1,955 in the drug-eluting stent [DES] group) being analyzed. The primary outcome measure-major adverse cardiovascular events (MACEs), target lesion revascularization (TLR), target vessel revascularization (TVR), myocardial infarction (MI), cardiac death (CD), stent thrombosis (ST), all-cause death (AD), and coronary angiography outcomes included late lumen loss (LLL), minimum luminal diameter (MLD), diameter stenosis (DS) were analyzed. RESULTS: DCB treatment significantly reduced the LLL (MD: -0.13; [CI -0.23 to -0.03], p = .01). No difference was found for MLD (MD: -0.1; [CI -0.24 to 0.04], p = .17) and DS% (RR = 0.98 [CI 0.80-1.20], p = .86). There was no significant difference in TLR, TVR, MI, CD, ST, AD, and the overall incidence of MACEs between the two groups up to 3 years follow-up. Subgroup analysis for different type of ISR and DES showed no significant difference in the incidence of endpoints, and there is no difference when considering RCTs or OSs only. CONCLUSIONS: The safety and efficacy of the DCB and DES in the treatment of ISR is comparable at up to 3 years follow-up.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Reestenose Coronária/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Stents , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Observacionais como Assunto , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
J Biomed Nanotechnol ; 11(10): 1819-25, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26502644

RESUMO

RATIONALE: We reported previously, in porcine coronary arteries, that the novel biodegradable PowerStent Absorb paclitaxel-eluting stent had improved and sustained structural strength and functional performance at one month post-implantation. OBJECTIVE: To report the stent performance at 6-month follow-up. METHODS AND RESULTS: Six PowerStent Absorb and six TAXUS stents were randomly implanted in the left anterior descending and right coronary arteries of six Tibet miniature pigs. Quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) images were obtained at the time of implantation (T0) and at 6 months (T6). Two animals were sacrificed at T6 for histopathological evaluation. At T6, QCA showed that the mean luminal vascular diameter (mLD) between the PowerStent and the TAXUS stents were similar (2.36 ± 0.38 vs. 2.61 ± 0.31, respectively). Based on the IVUS analysis, the mLD and the mean lumen cross-sectional area (mCSA) in the PowerStent-treated arteries were similar between T0 and T6 (mLD: 2.74 ± 0.13 vs. 2.70 ± 0.20 and mCSA: 6.81 ± 0.62 mm2 vs. 6.68 ± 0.94 mm2). Histopathology showed that the PowerStent stents were well apposed to the vessel wall with no recoil, strut fracture and thrombus formation. The stents were fully covered with a layer of endothelial cells. CONCLUSIONS: At six-month post-implantation, the PowerStent Absorb stents maintained their structural strength and functional performance. The development of restenosis was controlled, no stent thrombosis was observed and the stents were fully re-endothelialized. These results suggest the PowerStent Absorb stent is safe and effective for up to 6 months when implanted in porcine coronary arteries.


Assuntos
Fosfatos de Cálcio/química , Reestenose Coronária/prevenção & controle , Stents Farmacológicos , Ácido Láctico/química , Nanocápsulas/administração & dosagem , Paclitaxel/administração & dosagem , Polímeros/química , Implantes Absorvíveis , Animais , Reestenose Coronária/patologia , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/patologia , Implantes de Medicamento/administração & dosagem , Implantes de Medicamento/química , Seguimentos , Estudos Longitudinais , Teste de Materiais , Nanocápsulas/química , Paclitaxel/química , Poliésteres , Suínos
3.
J Biomed Nanotechnol ; 10(7): 1194-204, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24804540

RESUMO

Bioabsorbable drug-eluting stents (BDES) offer multiple advantages over a permanent bare metal stent (BMS) for coronary artery disease (CAD). However, current BDES remains two major issues: inferior radial strength and biocompatibility. PowerStent Absorb BDES, fabricated by co-formulating amorphous calcium phosphate (ACP) nanoparticles with poly-L-lactic acid (PLLA/ACP, 98/2, w/w) and 2% Paclitaxel (PAX, w/w) was designed to address these issues. Two cohorts of 6 miniature pigs were each implanted with PLLA/PAX (control, 2% PAX, w/w) or PowerStent Absorb BDES. After 1 month in-vivo study, histological analyses showed significantly reduced restenosis in the PowerStent Absorb BDES cohort relative to the control cohort (44.49 +/- 410.49% vs. 64.47 +/- 16.2%, p < 0.05). Stent recoil (21.57 +/- 5.36% vs. 33.81 +/- 11.49, P < 0.05) and inflammation (3.01 +/- 0.62 vs. 4.07 +/- 0.86, P < 0.01) were also obviously decreased. From in-vitro studies, PLLA/ACP/PAX stent tube maintained significantly greater radial strength than control group during 6 months in-vitro degradation (PLLA/ACP/PAX vs. PLLA/PAX: before hydrolysis: 82.4 +/- 1.9 N vs.74.8 +/- 3.8 N; 6 weeks: 73.9 +/- 1.8 N vs. 68.0 +/- 5.3 N; 3 months: 73.5 +/- 3.4 N vs.67.2 +/- 3.8 N; 6 months: 56.3 +/- 8.1 N vs. 57.5 +/- 4.9 N). Moreover, ACP facilitated the hydrolytic degradation of PLLA compared with control one (62.6% vs. 49.8%), meanwhile, it also increased the crystallinity of PLLA (58.4% vs. 50.7%) at 6 months. From SEM observations, ACP created nanometer pores that enlarge gradually to a micrometer scale as degradation proceeds. The changes of the porosity may result in greatly promoting re-endothelialization.


Assuntos
Materiais Biocompatíveis/química , Fosfatos de Cálcio/química , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Ácido Láctico/química , Nanopartículas/química , Polímeros/química , Animais , Varredura Diferencial de Calorimetria , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/patologia , Vasos Coronários/fisiopatologia , Feminino , Masculino , Teste de Materiais , Nanopartículas/ultraestrutura , Paclitaxel/farmacologia , Poliésteres , Radiografia , Suínos , Porco Miniatura
4.
J Biomed Nanotechnol ; 10(6): 900-10, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24749387

RESUMO

Biodegradable polymers used as vascular stent coatings and stent platforms encounter a major challenge: biocompatibility in vivo, which plays an important role in in-stent restenosis (ISR). Co-formulating amorphous calcium phosphate (ACP) into poly(lactic-co-glycolic acid) (PLGA) or poly-L-lactic acid (PLLA) was investigated to address the issue. For stent coating applications, metal stents were coated with polyethylene-co-vinyl acetate/poly-n-butyl methacrylate (PEVA/PBMA), PLGA or PLGA/ACP composites, and implanted into rat aortas for one and three months. Comparing with both PEVA/PBMA and PLGA groups after one month, the results showed that stents coated with PLGA/ACP had significantly reduced restenosis (PLGA/ACP vs. PEVA/PBMA vs. PLGA: 21.24 +/- 2.59% vs. 27.54 +/- 1.19% vs. 32.12 +/- 3.93%, P < 0.05), reduced inflammation (1.25 +/- 0.35 vs. 1.77 +/- 0.38 vs. 2.30 +/- 0.21, P < 0.05) and increased speed of re-endothelialization (1.78 +/- 0.46 vs. 1.17 +/- 0.18 vs. 1.20 +/- 0.18, P < 0.05). After three months, the PLGA/ACP group still displayed lower inflammation score (1.33 +/- 0.33 vs. 2.27 +/- 0.55, P < 0.05) and higher endothelial scores (2.33 +/- 0.33 vs. 1.20 +/- 0.18, P < 0.05) as compared with the PEVA/PBMA group. Moreover, for stent platform applications, PLLA/ACP stent tube significantly reduced the inflammatory cells infiltration in the vessel walls of rabbit iliac arteries relative to their PLLA cohort (NF-kappaB-positive cells: 23.31 +/- 2.33/mm2 vs. 9.34 +/- 1.35/mm2, P < 0.05). No systemic biochemical or pathological evidence of toxicity was found in either PLGA/ACP or PLLA/ACP. The co-formulation of ACP into PLGA and PLLA resulted in improved biocompatibility without systemic toxicity.


Assuntos
Implantes Absorvíveis/efeitos adversos , Prótese Vascular/efeitos adversos , Fosfatos de Cálcio/efeitos adversos , Ácido Láctico/efeitos adversos , Doença Arterial Periférica/etiologia , Ácido Poliglicólico/efeitos adversos , Polímeros/efeitos adversos , Stents/efeitos adversos , Animais , Materiais Biocompatíveis/efeitos adversos , Materiais Biocompatíveis/química , Fosfatos de Cálcio/química , Ácido Láctico/química , Masculino , Doença Arterial Periférica/patologia , Poliésteres , Ácido Poliglicólico/química , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Coelhos , Ratos , Ratos Sprague-Dawley
5.
J Immunol ; 180(9): 6159-67, 2008 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-18424737

RESUMO

A variety of DNA vaccine prime and recombinant viral boost immunization strategies have been developed to enhance immune responses in humans, but inherent limitations to these strategies exist. There is still an overwhelming need to develop safe and effective approaches that raise broad humoral and T cell-mediated immune responses systemically and on mucosal surfaces. We have developed a novel mucosal immunization regimen that precludes the use of viral vectors yet induces potent T cell responses. Using hepatitis B surface Ag (HBsAg), we observed that vaccination of BALB/c mice with an i.m. HBsAg-DNA vaccine prime followed by an intranasal boost with HBsAg protein encapsulated in biologically inert liposomes enhanced humoral and T cell immune responses, particularly on mucosal surfaces. Intranasal live virus challenge with a recombinant vaccinia virus expressing HBsAg revealed a correlation between T cell immune responses and protection of immunized mice. A shortened immunization protocol was developed that was successful in both adult and neonatal mice. These results support the conclusion that this new approach is capable of generating a Th-type-1-biased, broad spectrum immune response, specifically at mucosal surfaces. The success of this design may provide a safe and effective vaccination alternative for human use.


Assuntos
Antígenos de Superfície da Hepatite B/imunologia , Vacinas contra Hepatite B/imunologia , Imunidade nas Mucosas/fisiologia , Imunização Secundária , Células Th1/imunologia , Vacinas de DNA/imunologia , Administração Intranasal , Animais , Animais Recém-Nascidos , Formação de Anticorpos/efeitos dos fármacos , Formação de Anticorpos/fisiologia , Feminino , Antígenos de Superfície da Hepatite B/farmacologia , Vacinas contra Hepatite B/farmacologia , Humanos , Imunidade nas Mucosas/efeitos dos fármacos , Lipossomos , Camundongos , Camundongos Endogâmicos BALB C , Vacinas de DNA/farmacologia , Vaccinia virus/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA