Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 17: 188, 2016 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-27118194

RESUMO

BACKGROUND: Cross-linked hyaluronan--also called Hylan G-F 20--is a medical device developed to treat osteoarthritis of the knee. However, it is still controversial whether Hylan G-F 20 has a cartilage protective effect in trauma-induced osteoarthritis. We investigated whether Hylan G-F 20 delayed osteoarthritis progression in a partial meniscectomized rat model. METHODS: Lewis rats were used for the experiments. The anterior medial meniscus was resected at the level of the medial collateral ligament in both knees. From 1 week after the surgery, 50 µl of Hylan G-F 20 was injected weekly into the left knee and phosphate buffered saline was injected into the right knee. Cartilage was evaluated for macroscopic findings, histology with safranin-o, and expression of type II collagen at 2, 4, and 8 weeks. Synovitis was also evaluated, and immunohistochemical analysis was performed for ED1. RESULTS: Macroscopic findings demonstrated that India ink positive area, representing fibrillated cartilage, was significantly smaller in the Hylan G-F 20 group than in the control group at 2, 4, and 8 weeks (n = 5). There were no significant differences in osteophyte score between the Hylan G-F 20 group and the control group at 2, 4, and 8 weeks. Histologically, the cartilage in the medial tibial plateau was destroyed at 8 weeks in the control group, while type II collagen expression was still observed at 8 weeks in the Hylan G-F 20 group. OARSI score for cartilage histology was significantly lower in the Hylan G-F 20 group than in the control group at 4 and 8 weeks (n = 5). There were no significant differences in synovial cell number or modified synovitis score between the Hylan G-F 20 group and the control group at 2, 4, and 8 weeks (n = 5). In the Hylan G-F 20 group, foreign bodies surrounded by ED1 positive macrophages were observed in the synovium. CONCLUSION: Weekly injections of Hylan G-F 20 starting 1 week after surgery delayed cartilage degeneration after meniscectomy in a rat model. Synovitis induced by meniscectomy was not alleviated by Hylan G-F 20. Insoluble gels were observed in the synovium after the Hylan G-F 20 injection.


Assuntos
Materiais Biocompatíveis/administração & dosagem , Ácido Hialurônico/análogos & derivados , Meniscos Tibiais/cirurgia , Osteoartrite do Joelho/prevenção & controle , Osteoartrite do Joelho/cirurgia , Animais , Doenças das Cartilagens/patologia , Doenças das Cartilagens/prevenção & controle , Doenças das Cartilagens/cirurgia , Esquema de Medicação , Ácido Hialurônico/administração & dosagem , Articulação do Joelho/efeitos dos fármacos , Articulação do Joelho/patologia , Articulação do Joelho/cirurgia , Masculino , Meniscos Tibiais/efeitos dos fármacos , Meniscos Tibiais/patologia , Osteoartrite do Joelho/patologia , Ratos , Ratos Endogâmicos Lew
2.
Orthop Traumatol Surg Res ; 109(1): 103147, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-34793945

RESUMO

BACKGROUND: As no previous study has directly compared the linear wear rate in two types of second-generation annealed highly cross-linked polyethylene, we performed a retrospective study with a minimum of 5-year follow-up to assess primary arthroplasties in the (1) wear rates and (2) incidence of osteolysis of the two types of HXLPE. HYPOTHESIS: There was no significant difference in the linear wear rate and the incidence of osteolysis between the two types of second-generation annealed highly cross-linked polyethylene. PATIENTS AND METHODS: In this single-center study, we reviewed 257 cases of primary cementless total hip arthroplasties between 2011 and 2015, which were performed with 32mm delta ceramic on second-generation annealed highly cross-linked polyethylene (X3 and E1 were used in 105 and 103 cases, respectively.). The mean wear rate was evaluated using a computer-assisted method, and the incidence of osteolysis was evaluated based on the appearance of a localized area with loss of trabecular bone or cortical erosion adjacent to the implants during the latest follow-up. RESULTS: In total, we evaluated 208 cases, followed postoperatively for over 5 years (mean, 6.1 years, range: 5.0-8.0). There were no significant differences between the two groups with respect to age (list in order of Group X, Group E, p value) (61.2±12.3, 62.7±12.1, p=0.36), sex (ratio of male: 17.1%, 14.6%, p=0.61), body mass index (22.9±3.7, 22.8±4.0, p=0.91), pre- (49.9±14.8, 48.5±13.8, p=0.49) and post-operative (91.3±9.1, 92.7±7.0, p=0.23) Japanese Orthopaedic Association Hip Score, cup size (50.8±3.0, 50.9±2.2, p=0.70), cup inclination (38.7±4.8, 37.6±4.8, p=0.10), and cup anteversion (18.7±6.9, 18.5±7.6, p=0.80). The mean linear wear rates of the X3 and E1 groups were 0.057±0.039 (range: 0-0.16) and 0.054±0.037mm/year (range: 0-0.15), respectively (p=0.61). No osteolysis was found on the final plain radiographs in both groups. DISCUSSION: This study revealed that both types of highly cross-linked polyethylene have excellent linear wear rates and were equally safe to use. However, the difference between the two materials in terms of the long-term wear rate should be further validated. LEVEL OF EVIDENCE: III; retrospective case control study.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteólise , Masculino , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Polietileno , Estudos de Casos e Controles , Prótese de Quadril/efeitos adversos , Falha de Prótese , Desenho de Prótese , Osteólise/diagnóstico por imagem , Osteólise/epidemiologia , Osteólise/etiologia , Seguimentos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA