Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Am J Cardiol ; 100(5): 812-7, 2007 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-17719325

RESUMO

This study was conducted to determine the influence of lesion preparation using the AngioSculpt balloon on final stent expansion. Stent expansion remains an important predictor of restenosis and subacute thrombosis, even in the drug-eluting stent (DES) era. In these patients, the role of different predilation strategies has yet to be established. Two hundred ninety-nine consecutive de novo lesions treated with 1 >2.5-mm DES (Cypher or Taxus) under intravascular ultrasound guidance without postdilation, using 3 implantation strategies, were studied: (1) direct stenting without predilation (n = 145), (2) predilation with a conventional semi-compliant balloon (n = 117), and (3) predilation with the AngioSculpt balloon (n = 37). Stent expansion was defined as the ratio of intravascular ultrasound-measured minimum stent diameter and minimum stent area to the manufacturer's predicted stent diameter and area. These ratios were larger after AngioSculpt predilation, and a greater percentage of stents had final minimum stent areas >5.0 mm(2) (another commonly accepted criterion of adequate DES expansion). Lesion morphology, stent and lesion length, and reference vessel size did not affect DES expansion. In conclusion, in this observational, nonrandomized study, pretreatment with the AngioSculpt balloon enhanced stent expansion and minimized the difference between predicted and achieved stent dimensions.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Vasos Coronários/diagnóstico por imagem , Endossonografia , Stents , Ultrassonografia de Intervenção , Idoso , Ligas , Angioplastia Coronária com Balão/métodos , Fármacos Cardiovasculares/uso terapêutico , Vasos Coronários/patologia , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/uso terapêutico , Pressão , Estudos Prospectivos , Sirolimo/uso terapêutico , Propriedades de Superfície
2.
Am J Cardiol ; 98(4): 436-42, 2006 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-16893693

RESUMO

We investigated the fate of postprocedural incomplete stent apposition (ISA) after sirolimus-eluting stent (SES) implantation by evaluating long-term intravascular ultrasound findings in 168 consecutive patients (182 de novo lesions). Postprocedural ISA was defined as > or = 1 stent strut that was clearly separated from the vessel wall with evidence of blood speckle behind the strut without overlapping a side branch. After SES implantation, there were 61 ISA sites in 46 stents in 31 patients (23 at the proximal edge, 7 at the distal edge, and 31 within the stent body). There were no clinical, procedural, or intravascular ultrasound measurement differences between patients and lesions with versus without ISA. At follow-up, 15 acute ISA sites (25%) in 11 patients completely resolved and 40 sites (75%) in 20 patients persisted, although 32 of 46 persisting ISA sites (70%) decreased. There was a greater decrease in effective lumen area and a greater increase in peristent plaque area in the complete-resolution group than in the persistent-ISA group. No lesion developed stent thrombosis or in-stent restenosis (angiographic diameter stenosis > 50%). Six acute ISA sites were also associated with new, late acquired ISA, only 1 of which resulted in aneurysm formation. Although most ISAs after SES implantation do not resolve completely, the incidence of restenosis or thrombosis is not affected.


Assuntos
Implante de Prótese Vascular/efeitos adversos , Materiais Revestidos Biocompatíveis , Estenose Coronária/diagnóstico por imagem , Imunossupressores/uso terapêutico , Sirolimo/uso terapêutico , Stents , Ultrassonografia de Intervenção/métodos , Doença Aguda , Implante de Prótese Vascular/instrumentação , Estenose Coronária/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Falha de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA