RESUMO
Nickel oxide (NiO) nanoparticles (NPs) and graphene quantum dots (GQDs) reinforced polyvinyl alcohol (PVA) nanocomposite films were prepared using a solution casting technique. The physicochemical characteristics of PVA/NiO/GQDs (PNG) nanocomposite films were studied using Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), thermogravimetric analysis (TGA), and field emission scanning electron microscopy (FESEM). The obtained PNG nanocomposite films showed good mechanical flexibility and improved tensile strength. The influence of nanofiller concentrations on PNG nanocomposite film. The obtained results demonstrate an increase in the activation energy (Ea) up to PNG3 upon increasing the GQDs concentration and thereafter, its decreases. The fundamental interactions of the constituents of PNG nanocomposite film were investigated using density functional theory (DFT). This study on electronic structure reveals that the PVA model indirectly interacts with GQDs through the NiO model. This configuration is favoured in terms of interaction energy (-78 kJ/mol) compared to the one in which PVA interacts directly with the GQDs model.
Assuntos
Grafite , Nanocompostos , Nanopartículas , Pontos Quânticos , Níquel , Álcool de Polivinil , Espectroscopia de Infravermelho com Transformada de FourierRESUMO
PURPOSE: This computational study explores modelling and finite element study of the implant under Intracranial pressure (ICP) conditions with normal ICP range (7 mm Hg to 15 mm Hg) or increased ICP (>I5 mm Hg). The implant fixation points allow implant behaviour with respect to intracranial pressure conditions. However, increased fixation points lead to variation in deformation and equivalent stress. Finite element analysis is providing a valuable insight to know the deformation and equivalent stress. METHODS: The patient CT data (Computed Tomography) is processed in Mimics software to get the mesh model. The implant is modelled by using modified reverse engineering technique with the help of Rhinoceros software. This modelling method is applicable for all types of defects including those beyond the middle line and multiple ones. It is designed with eight fixation points and ten fixation points to fix an implant. Consequently, the mechanical deformation and equivalent stress (von Mises) are calculated in ANSYS 15 software with distinctive material properties such as Titanium alloy (Ti6Al4V), Polymethyl methacrylate (PMMA) and polyether-ether-ketone (PEEK). RESULTS: The deformation and equivalent stress results are obtained through ANSYS 15 software. It is observed that Ti6Al4V material shows low deformation and PEEK material shows less equivalent stress. Among all materials PEEK shows noticeably good result. CONCLUSIONS: Hence, a concept was established and more clinically relevant results can be expected with implementation of realistic 3D printed model in the future. This will allow physicians to gain knowledge and decrease surgery time with proper planning.