Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Neural Eng ; 20(2)2023 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-36863014

RESUMO

Objective.Reliable and user-friendly electrodes can continuously and real-time capture the electroencephalography (EEG) signals, which is essential for real-life brain-computer interfaces (BCIs). This study develops a flexible, durable, and low-contact-impedance polyvinyl alcohol/polyacrylamide double-network hydrogel (PVA/PAM DNH)-based semi-dry electrode for robust EEG recording at hairy scalp.Approach.The PVA/PAM DNHs are developed using a cyclic freeze-thaw strategy and used as a saline reservoir for semi-dry electrodes. The PVA/PAM DNHs steadily deliver trace amounts of saline onto the scalp, enabling low and stable electrode-scalp impedance. The hydrogel also conforms well to the wet scalp, stabilizing the electrode-scalp interface. The feasibility of the real-life BCIs is validated by conducting four classic BCI paradigms on 16 participants.Main results.The results show that the PVA/PAM DNHs with 7.5 wt% PVA achieve a satisfactory trade-off between the saline load-unloading capacity and the compressive strength. The proposed semi-dry electrode exhibits a low contact impedance (18 ± 8.9 kΩ at 10 Hz), a small offset potential (0.46 mV), and negligible potential drift (1.5 ± 0.4µV min-1). The temporal cross-correlation between the semi-dry and wet electrodes is 0.91, and the spectral coherence is higher than 0.90 at frequencies below 45 Hz. Furthermore, no significant differences are present in BCI classification accuracy between these two typical electrodes.Significance.Based on the durability, rapid setup, wear-comfort, and robust signals of the developed hydrogel, PVA/PAM DNH-based semi-dry electrodes are a promising alternative to wet electrodes in real-life BCIs.


Assuntos
Interfaces Cérebro-Computador , Couro Cabeludo , Humanos , Álcool de Polivinil , Eletroencefalografia/métodos , Hidrogéis , Eletrodos
2.
Sci Rep ; 3: 2796, 2013 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-24077449

RESUMO

There is an increasing trend towards cementless modular femoral prostheses for revision hip replacement surgery, especially in patients with severe proximal femoral bone defects. However, for minor femoral bone defects, the benefit of cementless modular is not clear. We designed a retrospective cross-sectional study to compare outcomes of the two femoral implant designs. There were no significant differences in terms of visual analog pain scores, Harris hip scores, femoral bone restoration, stem subsidence, leg length correction, or overall complication rate. Three femoral reoperations (11%) occurred in the cemented group, and two (9%) in the cementless modular group. One femoral stem re-revised (4%) in the cemented group due to recurrent deep infection. Five-year survival for femoral reoperation was 88.2% for patients with the cemented implant and 91.3% for cementless group. Both groups had good clinical and radiological outcomes for femoral revision in patients with minor femoral bone defects during medium-term follow-up.


Assuntos
Artroplastia de Quadril , Cimentos Ósseos/farmacologia , Prótese de Quadril , Reoperação , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/mortalidade , Cimentos Ósseos/efeitos adversos , Feminino , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Cuidados Pré-Operatórios , Reoperação/efeitos adversos , Reoperação/mortalidade , Taxa de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA