Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Sep Sci ; 38(19): 3477-86, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26226935

RESUMO

A novel bovine serum albumin (BSA) surface imprinted polymer based on ZnO rods was synthesized by surface grafting copolymerization. It exhibited an excellent recognition performance to bovine serum albumin. The adsorption capacity and imprinting factor of bovine serum albumin could reach 89.27 mg/g and 2.35, respectively. Furthermore, the fluorescence property of ZnO was used for tracing the process of protein imprinting and it implied the excellent optical sensing property of this material. More importantly, the hypothesis that the surface charge of carrier could affect the imprinting process was confirmed. That is, ZnO with positive surface charge could not only improve the recognition specificity of binding sites to template proteins (pI < 7), but also deteriorate the bindings between sites and non-template proteins (pI > 7). It was also important that the reusability of ZnO@BSA molecularly imprinted polymers was satisfactory. This implied that the poor mechanical/chemical stability of traditional zinc oxide sensors could be solved by the introduction of surface grafting copolymerization. These results revealed that the ZnO@BSA molecularly imprinted polymers are a promising optical/electrochemical sensor element.


Assuntos
Técnicas Biossensoriais/métodos , Impressão Molecular/métodos , Soroalbumina Bovina/química , Óxido de Zinco/química , Adsorção , Animais , Materiais Biomiméticos/química , Bovinos , Nanopartículas Metálicas/química , Nanopartículas Metálicas/ultraestrutura , Microscopia Eletrônica de Varredura , Nanotubos/química , Nanotubos/ultraestrutura , Polimerização , Polímeros/química , Propriedades de Superfície
2.
Clin Oral Investig ; 19(2): 329-34, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24737101

RESUMO

OBJECTIVES: This study aims to explore the correlation between radicular grooves and root canal types by quantitatively detecting the radicular groove of mandibular first premolars using micro-computed tomography. MATERIALS AND METHODS: A total of 127 mandibular first premolars were scanned by micro-computed tomography, and 52 teeth with radicular grooves were identified. Details of root canal type and groove length, depth, and location were analyzed from three-dimensional images. RESULTS: A total of 40.9 % (52/127) of teeth had radicular grooves. Most of the grooves (69.5 %) were located on the mesial surface of the root. The prevalence of radicular grooves in single canals (17.4 %; 15/86) was lower than that in multiple and complex canals (90.2 %; 37/41); this difference was statistically significant (P < 0.001). The mean length and depth of radicular groove in type V (7.7 ± 2.16 and 0.87 ± 0.39 mm, respectively) and other types of canals (6.91 ± 2.67 and 0.63 ± 0.27 mm, respectively) were significantly longer and deeper than type I canals (6.06 ± 2.12 and 0.43 ± 0.14 mm, respectively). CONCLUSIONS: Multiple and complex canals had a higher incidence of radicular grooves and more complicated root morphology than single and simple canals. Therefore, the anatomy of radicular grooves may influence root canal morphology. CLINICAL RELEVANCE: The existence of a radicular groove is closely related to root anatomy and root canal morphology. Anatomical complexity increases the difficulty of root canal treatment and periodontal therapy; therefore, the current data may provide clinicians with a more thorough understanding of the relationship between radicular grooves and root canal morphology.


Assuntos
Cavidade Pulpar/anatomia & histologia , Mandíbula/anatomia & histologia , Microtomografia por Raio-X/métodos , Humanos
3.
Am J Med Genet A ; 161A(5): 983-92, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23495007

RESUMO

Apert syndrome is a common craniosynostosis caused by gain-of-function missense mutations of fibroblast growth factor receptor 2 (FGFR2). Mice with the FGFR2 S252W mutation can elucidate the mechanism by which the human Apert syndrome phenotypes arise. However, many studies have focused on mutant skull and long bone malformation, only few studies have focused on mandible changes. Bone formation and micro-architecture between 28- and 56-day-old mutant mice and controls were compared to investigate the changes in the mandibular micro-architecture caused by the Fgfr2(S252W/+) mutation to provide a basis for exploring the pathogenesis and therapeutic measures of human Apert syndrome. Fgfr2(S252W/+) mutant mice were established, and their general characteristics, including weight, naso-anal length, and calcium and phosphate content in serum and bone were tested. Calcein labeling, tartrate-resistant acid phosphatase staining and toluidine blue staining were used to detect osteoblast and osteoclast activities. H&E staining and micro-CT detection were used to test micro-architecture changes. The changes in mineral apposition rate and micro-architecture of the Fgfr2(S252W/+) mice were statistically significant; however, the magnitude of the micro-architecture became less with age. The Fgfr2(S252W/+) mutation may retard mandibular bone formation, decreased bone volume, and compromised skeletal architecture by regulating both osteoblastogenesis and osteoclastogenesis.


Assuntos
Acrocefalossindactilia/genética , Densidade Óssea/genética , Osso e Ossos/metabolismo , Cálcio/sangue , Mandíbula/patologia , Osteogênese/genética , Fosfatos/sangue , Receptor Tipo 2 de Fator de Crescimento de Fibroblastos/genética , Animais , Osso e Ossos/patologia , Modelos Animais de Doenças , Humanos , Mandíbula/metabolismo , Camundongos , Mutação
4.
Clin Oral Investig ; 17(3): 999-1007, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22777390

RESUMO

OBJECTIVES: This study aimed to investigate the root canal morphology of mandibular first premolar teeth in a population from southwestern China by micro-computed tomography (micro-CT). MATERIALS AND METHODS: Human mandibular first premolars (115) were selected and prepared for micro-CT analysis with a slice thickness of 30 µm. Details of root canal orifices, canals, accessory canals, apical foramina-apical delta intercanal communication, loops and isthmuses, and mesial invagination were analyzed from reconstructed three-dimensional (3D) images. RESULTS: Canal patterns categorized according to the classification defined by Vertucci (Endod Top 10:3-29, 2005) as types I (65.2%), III (2.6%), V (22.6%), and VII were identified (0.9%). Accessory canals were present in 35.7% of the samples and were predominantly located in the apical third of the root. A single apical foramen was observed in 50.4% of the samples and two or three foramina in 28.7% and 14.8%, respectively. Apical delta was identified in 6.1% of the samples and the prevalence of intercanal communication and loops was 3.5% and 7%, respectively. Mesial invagination of the root was identified in 27.8% of the samples, the majority of which contained multiple canals. CONCLUSIONS: The data obtained in this study revealed complex root morphology with high prevalence of multiple canals, more than half of which exhibited type I canal patterns. CLINICAL RELEVANCE: Micro-CT was used as a noninvasive technique for 3D investigation of root canal morphology in the mandibular first premolars of a population from southwestern China. Furthermore, data obtained revealed complex anatomy of various types.


Assuntos
Dente Pré-Molar/anatomia & histologia , Cavidade Pulpar/anatomia & histologia , Cavidade Pulpar/diagnóstico por imagem , Microtomografia por Raio-X , Dente Pré-Molar/diagnóstico por imagem , China , Feminino , Humanos , Masculino , Mandíbula
5.
J Chromatogr A ; 1438: 171-8, 2016 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-26896914

RESUMO

Boronate-affinity monolithic column was first prepared via polystyrene (PS) as porogen in this work. The monolithic polymer was synthetized using 4-vinylphenylboronic acid (4-VPBA) as functional monomer, ethylene glycol dimethacrylate (EDMA) as crosslinker monomer, and a mixture of PS solution in tetrahydrofuran, the linear macromolecular porogen, and toluene as porogen. Isoquercitrin (ISO) and hyperoside (HYP), isomer diol flavonoid glycosides, can be baseline separated on the poly(VPBA-co-EDMA) monolith. The effect of polymerization variables on the selectivity factor, e.g., the ratio of monomer to crosslinker (M/C), the amount of PS and the molecular weight of macromolecular porogen was investigated. The surface properties of the monolithic polymer were characterized by scanning electron microscopy and nitrogen adsorption. The best polymerization condition was the M/C ratio of 7:3, and the PS concentration of 40 mg/ml. The poly(VPBA-co-EDMA) polymer was also applied to extract cis-diol flavonoid glycosides from the crude extraction of cotton flower. After treated by poly(VPBA-co-EDMA) for solid phase extraction, high purity ISO and HYP (>99.96%) can be obtained with recovery of 83.7% and 78.6%, respectively.


Assuntos
Ácidos Borônicos/química , Polímeros/síntese química , Extração em Fase Sólida/métodos , Adsorção , Substâncias Macromoleculares/química , Metacrilatos/química , Peso Molecular , Polimerização , Polímeros/química , Poliestirenos/química
6.
Biosens Bioelectron ; 51: 261-7, 2014 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-23973936

RESUMO

A novel bovine serum albumin surface-imprinted thermosensitive magnetic composite microsphere was successfully prepared by the surface grafting copolymerization method in the presence of temperature-sensitive monomer N-isopropylacrylamide (NIPAM), functional monomer methacrylic acid (MAA) and cross-linking agent N,N'-methylenebisacrylamide (MBA). The structure and component of the thermosensitive magnetic molecularly imprinted microsphere were investigated by transmission electron microscopy (TEM), Fourier transform infrared (FT-IR), vibrating sample magnetometer (VSM) and thermogravimetric analysis (TGA). The results of thermosensitivity, adsorption capacity, selectivity and reusability showed the formation of a thermosensitivity grafting polymer layer P(NIPAM-MAA-MBA) on the surface of Fe3O4@SiO2 and the good adsorption capacity and specific recognition for template protein. When the adsorption temperature was higher than the lower critical solution temperature (LCST) of poly(N-isopropylacrylamide) (PNIPAM), shape memory effect of imprinted cavities would be more effective. In other words, it was more conducive to capture template molecules under this condition and the imprinting factor would be higher. On the other hand, when the desorption temperature was lower than LCST of PNIPAM, the decrease of shape memory effect between imprinted cavities and template molecules would facilitate the release of template molecules from the imprinted cavities. Based on this property, the adsorption and desorption of template molecules could be regulated by system temperature indirectly which benefited from the existence of thermosensitivity imprinting layer.


Assuntos
Técnicas Biossensoriais/métodos , Imãs/química , Impressão Molecular , Soroalbumina Bovina/isolamento & purificação , Acrilamidas/química , Resinas Acrílicas/química , Adsorção , Animais , Bovinos , Óxido Ferroso-Férrico/química , Metacrilatos/química , Microesferas , Dióxido de Silício/química , Temperatura
7.
J Colloid Interface Sci ; 398: 51-8, 2013 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-23511014

RESUMO

In this work, Fe3O4/P(acrylic acid-methyl methacrylate-N-isopropylacrylamide) (Fe3O4/P(AA-MMA-NIPAm)) thermoresponsive magnetic composite microspheres have been prepared by controlled radical polymerization in the presence of 1,1-diphenylethene (DPE). The shell thickness of thermosensitive polymer (PNIPAm), which was on the surface of the microspheres, can be controlled by using DPE method. The morphology and thermosensitive properties of the composite microspheres, polymerization mechanism of the shell were characterized by TEM, FTIR, VSM, Laser Particle Sizer, TGA, NMR, and GPC. The microspheres with narrow particle size distribution show high saturation magnetization and superparamagnetism. The thermosensitive properties of the composite microspheres can be adjusted indirectly via controlling the addition amount of monomer (NIPAm) in the second step during controlled radical polymerization. Phenolphthalein was chosen as a model drug to investigate drug release behavior of the thermoresponsive magnetic composite microspheres with different shell thickness. Controlled drug release testing reveals that the release behavior depends on the thickness of polymer on the surface of the microspheres.


Assuntos
Acrilamidas/química , Acrilatos/química , Preparações de Ação Retardada/química , Compostos Férricos/química , Microesferas , Fenolftaleína/química , Metilmetacrilato
8.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 30(1): 57-60, 2012 Feb.
Artigo em Zh | MEDLINE | ID: mdl-22389968

RESUMO

OBJECTIVE: To compare the consistency of root canal configuration types of mandibular first premolar by using micro-CT and radio visio graphy (RVG). METHODS: One hundred extracted mandibular first premolars with complete dental root and apex which received no endodontic treatment were randomly selected. Each tooth was radiographed with RVG through a buccolingual and mesiodistal direction, and then scanned with micro-CT and reconstructed. The classifications of the root canal types according to Vertucci's type with the two methods were compared. RESULTS: The canal patterns were classified as type I (67%), type III (3%), type V (18%), type VII (2%), additional type (10%) with micro-CT and canal patterns as type I (71%), type III (2%), type V (23%), type VII (1%), additional type (3%) with RVG. 63% of teeth showed one canal in both micro-CT and RVG. Only 25% of teeth were diagnosed as complex canal by the same canal type in both micro-CT and RVG. The Kappa value between micro-CT and RVG was 0.541 which suggested that the two kinds of methods had intermediate consistency. 82.8% of the premolars with root groove had two or more than two canals. CONCLUSION: Although RVG can basically reflect the root canal system type of the mandibular first premolars in vitro, it offers poor accuracy images to complex root canals. Micro-CT three-dimensional images could clearly and precisely display the root canal system morphology of the mandibular first pre-molars in vitro.


Assuntos
Dente Pré-Molar , Microtomografia por Raio-X , Cavidade Pulpar , Humanos , Mandíbula , Dente Molar , Tratamento do Canal Radicular , Raiz Dentária
9.
J Endod ; 38(3): 309-12, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22341066

RESUMO

INTRODUCTION: Little is known about the lingual canal in the Vertucci type V mandibular first premolar. This study investigated the location of the lingual canal orifice and the curvature of the lingual canal by using micro-computed tomography. METHODS: One hundred fifteen mandibular first premolars were scanned by micro-computed tomography, reconstructed 3-dimensionally by using Mimics 10.01 software, and displayed in parallel projection mode. Twenty-six teeth with Vertucci type V canal were selected for further study. The lingual canal orifice was located by measurements made in both lingual and proximal views. The angle alpha (α) between the start of the lingual canal and the main canal and the angle beta (ß) of the curvature of lingual canal were also measured. RESULTS: In proximal view, 69% of lingual canals were located in the middle third of the tooth and the remainder in the apical third. In lingual view, 73% were located in the middle third of the root and the remainder in the coronal third. Mean angle α and angle ß were 33.54° and 26.66°, respectively, in proximal view and 8.31° and 11.31°, respectively, in lingual view (P < .05). The highest values of angles α and ß were observed in proximal view (65.24°and 43.39°, respectively). In most cases, angles α and ß were severely curved in proximal view and straight or only slightly curved in lingual view. CONCLUSIONS: Detailed information on the lingual canal is essential for successful endodontic treatment in patients with mandibular first premolar. The view used for imaging influences the information obtained.


Assuntos
Dente Pré-Molar/diagnóstico por imagem , Cavidade Pulpar/diagnóstico por imagem , Mandíbula/diagnóstico por imagem , Microtomografia por Raio-X/métodos , Dente Pré-Molar/anormalidades , Cavidade Pulpar/anormalidades , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Odontometria , Ápice Dentário/diagnóstico por imagem , Microtomografia por Raio-X/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA