Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
BMC Musculoskelet Disord ; 21(1): 460, 2020 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-32660462

RESUMO

BACKGROUND: Polymethylmethacrylate (PMMA) is commonly used for cement-augmented pedicle screw instrumentation (CAPSI) to improve the fixation stability and reduce the risk of screw loosening in the osteoporotic thoracolumbar spine. Biomechanical researches have shown that various dose of cement (1-3 ml) can be injected to enhance screw stability. To date, there have been no studies on the relationship between adjacent segment degeneration and the volume of PMMA. This study aimed to explore the influence of CAPSI with different volumes of PMMA in osteoporotic lumbar vertebrae over adjacent segments by using finite element analysis. METHODS: Seven different finite element models were reconstructed and simulated under different loading conditions, including (1) an intact model, (2) three single-level CAPSI models with different volumes of PMMA (1, 1.73, and 2.5 ml), and (3) three double-level CAPSI models with different volumes of PMMA (1, 1.73, and 2.5 ml). To improve the accuracy of the finite element analysis, the models of the injectable pedicle screw and bone cement were created by using a three-dimensional scanning machine and the CAPSI patient's CT data, respectively. The range of motion (ROM), the stress of intervertebral discs, and the stress of facet in the adjacent segment were comparatively analyzed among the different models. RESULTS: The ROMs of the different segments were compared with experimental data, with good agreement under the different load conditions (21.3°, 13.55°, 13.99°, and 6.11° in flexion, extension, bending, and rotation at L3-S1 level, respectively). Compared with the intact model, the ROM, disc stresses, and facet stress in adjacent segments were found to be higher in the six operative models. Otherwise, with a larger volume of PMMA injected, the ROM, disc stresses, and facet stress slightly increased at the adjacent segment. However, the differences were insignificant with the biggest difference less than 3.8%. CONCLUSIONS: CAPSI could increase the incidence of disk degeneration in the adjacent segment, while within a certain range, different volumes of PMMA provided an approximate impact over the adjacent segment degeneration.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Fenômenos Biomecânicos , Cimentos Ósseos , Análise de Elementos Finitos , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Polimetil Metacrilato , Amplitude de Movimento Articular , Fusão Vertebral/efeitos adversos
2.
BMC Musculoskelet Disord ; 21(1): 274, 2020 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-32345282

RESUMO

BACKGROUND: The increase of augmented level and bone cement dose are accompanied by the rising incidence of cement leakage (CL) of cement-augmented pedicle screw instrumentation (CAPSI). But the effect and potential risks of the application of CAPSI to osteoporotic lumbar degenerative disease (LDD) have not been studied in the case of multilevel fixation. This study aimed to investigate the effectiveness and potential complications of using multilevel CAPSI for patients with osteoporotic LDD. METHODS: A total of 93 patients with multilevel LDD were divided into the CAPSI group (46 subjects) and the conventional pedicle screw (CPS) group (47 subjects), including 75 cases for three levels and 18 cases for four levels. Relevant data were compared between two groups, including baseline data, clinical results, and complications. RESULTS: In the CAPSI group, a total of 336 augmented screws was placed bilaterally. The CL was observed in 116 screws (34.52%). Three cemented screws (0.89%) were found loosened during the follow-up and the overall fusion rate was 93.47%. For perioperative complications, two patients (4.35%) experienced pulmonary cement embolism (PCE), one patient augmented vertebral fracture, and three patients (6.52%) wound infection. And in the CPS group, thirty-three screws (8.46%) suffered loosening in cranial and caudal vertebra with a fusion rate of 91.49%. The operation time and hospital stay of CAPSI group were longer than the CPS group, but CAPSI group has a lower screw loosening percentage (P<0. 05). And in terms of blood loss, perioperative complications, fusion rate, and VAS and ODI scores at the follow-up times, there were no significant differences between the two groups. CONCLUSIONS: Patients with osteoporotic LDD underwent multilevel CPS fixation have a higher rate of screw loosening in the cranial and caudal vertebra. The application of cemented pedicle screws for multilevel LDD can achieve better stability and less screw loosening, but it also accompanied by longer operating time, higher incidence of CL, PCE and wound infections. Selective cement augmentation of cranial and caudal pedicle screws may be a worthy strategy to decrease the complications.


Assuntos
Cimentos Ósseos/efeitos adversos , Degeneração do Disco Intervertebral/cirurgia , Vértebras Lombares/cirurgia , Parafusos Pediculares/efeitos adversos , Fusão Vertebral/instrumentação , Absorciometria de Fóton , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Tempo de Internação , Vértebras Lombares/patologia , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Osteoporose/complicações , Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/cirurgia , Falha de Prótese/tendências , Embolia Pulmonar/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Fraturas da Coluna Vertebral/cirurgia , Infecção da Ferida Cirúrgica/epidemiologia
3.
Eur Spine J ; 28(7): 1661-1669, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31030261

RESUMO

PURPOSE: To evaluate the incidence, type and risk factors of cement leakage (CL) with cement-augmented pedicle screw instrumentation (CAPSI) in degenerative lumbosacral disease. METHODS: Two hundred and two patients using a total of 950 cement-augmented screws were enrolled. CL was classified into three types: type S: leakage via segmental veins; type B: leakage via basivertebral veins; and type I: leakage via pedicle screw instrumentation to paravertebral soft tissue. The age, gender, operation stage (primary or later stage), body mass index, bone mineral density, the number and type of augmented screw, the position of the tip of screw (lateral or internal part of vertebral body), the position of screw (left or right side), the volume of bone cement, location of the augmented vertebra (lumbar or sacrum), the type of CL and complications were recorded. Binary logistic regression correlation was used to analyze risk factors of veins leakage (type S and type B). RESULTS: The CL was observed in 165 patients (81.68%) and 335 screws (35.26%), leakage types of S, B and I were seen in 255 (76.12%), 77 (22.99%), and 30 (8.96%) of screws, respectively. Besides, double or multiple routes of leakage were seen in 27 screws. Number of augmented screw was a risk factor for vein leakage (OR 0.58; 95% CI 0.44-0.77; P = 0.000). Furthermore, the doses of cement (OR 0.79; 95% CI 0.61-0.99; P = 0.038) and the position of screw (OR 0.39; 95% CI 0.29-0.53; P = 0.000) were identified as risk factors for type S, and the doses of bone cement (OR 0.37; 95% CI 0.25-0.54; P = 0.000) and the position of the tip of screw (OR 0.07; 95% CI 0.04-0.13; P = 0.000) were risk factors for type B. CONCLUSIONS: CAPSI bears a high risk of asymptomatic CL, with a higher rate of leakage into segmental veins and basivertebral veins. As is known, more augmented screws and larger doses of cement are risk factors for veins leakage (type S and type B), while the tip of screw approaching to the midline of the vertebral body is another risk factor to type B. Thus, the CL could be reduced by the amelioration of operative techniques and procedures. These slides can be retrieved under Electronic Supplementary Material.


Assuntos
Cimentos Ósseos/efeitos adversos , Vértebras Lombares/cirurgia , Parafusos Pediculares , Complicações Pós-Operatórias/etiologia , Sacro/cirurgia , Doenças da Coluna Vertebral/cirurgia , Fusão Vertebral/instrumentação , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos , Resultado do Tratamento
4.
Int Orthop ; 42(9): 2131-2139, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29464371

RESUMO

PURPOSE: Re-collapse of cemented vertebrae occasionally occurs after percutaneous augmentation. However, the potential risks still remain unclear. Several articles have reported some possible risk factors which were not consistent or comprehensive. This study aimed to make a retrospective review on patients with osteoporotic vertebral compression fracture (OVCF) after percutaneous vertebroplasty (PVP) or percutaneous kyphoplasty (PKP) and to further analyse the risk factors for treated vertebral refracture. METHODS: All patients receiving the PKP/PVP with bilateral approach were retrospectively reviewed from January 2014 to January 2016, among whom 230 patients with single level augmentation (30 in refracture group and 200 in the non-refracture group) were enrolled according to inclusion criteria. The following covariates were reviewed: gender, age, height, weight, body mass index (BMI), bone mineral density (BMD), serum bone turnover markers, surgical parameters including approach, cement volume, anterior height, and Cobb angle restoration. Binary logistic regression analysis was used to determine the relative risk of re-collapse of cemented vertebrae. RESULTS: Regarding the patient data, weight, BMI, and BMD were of statistical significance in refracture group (P < 0.01), among which only low BMD was a risk factor to cemented vertebral re-collapse (P = 0.022, OR = 4.197). In respect of surgical variables, the better restoration of anterior height and Cobb angle was found in refracture group (P < 0.05), both of which might increase the refracture risk but not be risk factors (P = 0.065, OR = 0.891, and P = 0.937, OR = 0.996, respectively). Besides, less injected cement (3.30 ± 0.84 ml vs 4.46 ± 1.10 ml, P = 0.000, OR = 19.433) and PKP (P = 0.007, OR = 13.332) significantly boosted the potential risk of refracture (P < 0.001). CONCLUSION: Patients with low BMD, or undergoing PKP, or receiving a low volume of injected cement might have a high risk of re-collapse in surgical vertebrae.


Assuntos
Fraturas por Compressão/cirurgia , Cifoplastia/efeitos adversos , Fraturas por Osteoporose/cirurgia , Fraturas da Coluna Vertebral/cirurgia , Vertebroplastia/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Cimentos Ósseos/efeitos adversos , Densidade Óssea , Feminino , Humanos , Cifoplastia/métodos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Vertebroplastia/métodos
5.
Zhonghua Nan Ke Xue ; 19(10): 945-8, 2013 Oct.
Artigo em Zh | MEDLINE | ID: mdl-24218953

RESUMO

Microparticles are submicron vesicles shed from plasma membranes in response to cell activation, injury and/or apoptosis. Microparticles of various cellular origins, such as platelets, leukocytes, and endothelial cells, are found in the plasma of healthy subjects, and their amount increases under pathological conditions. Recent studies show that endothelial microparticles, a kind of envelope particles derived from endothelial cells, not only constitute a marker of endothelial dysfunction, but also play a major biological role in the diagnostic and therapeutic approaches to erectile dysfunction.


Assuntos
Células Endoteliais , Disfunção Erétil , Lipossomos/metabolismo , Biomarcadores , Membrana Celular , Células Endoteliais/metabolismo , Células Endoteliais/patologia , Disfunção Erétil/metabolismo , Disfunção Erétil/patologia , Humanos , Masculino
6.
Sci Rep ; 11(1): 13647, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34211025

RESUMO

This study aimed to evaluate the efficacy and safety of bone cement-augmented pedicle screw fixation for stage III Kümmell disease. Twenty-five patients with stage III Kümmell disease who received bone cement-augmented pedicle screw fixation at the First Affiliated Hospital of Guangzhou University of Chinese Medicine between June 2009 and December 2015 were enrolled. All patients were females with a history of osteoporosis. The vertebral Cobb angle (V-Cobb angle), the fixed segment Cobb Angle (S-Cobb angle), pelvic parameters, visual Analogue Scale (VAS) score, and Oswestry Disability Index (ODI) were assessed preoperatively, postoperatively and at the final follow-up. Complications, loosening rate, operation time, and intraoperative bleeding were recorded. The average lumbar vertebral density T-value was - 3.68 ± 0.71 SD, and the average age was 71.84 ± 5.39. The V-Cobb angle, S-Cobb angle, and Sagittal Vertical Axis (SVA) were significantly smaller postoperatively compared to the preoperative values. The VAS and ODI at 1 month after surgery were 3.60 ± 1.00 and 36.04 ± 6.12%, respectively, which were both significantly lower than before surgery (VAS: 8.56 ± 1.04, ODI: 77.80 ± 6.57%). Bone cement-augmented pedicle screw fixation is a safe and effective treatment for stage III Kümmell disease. It can effectively correct kyphosis, restore and maintain sagittal balance, and maintain spinal stability.


Assuntos
Cimentos Ósseos/uso terapêutico , Fixação Interna de Fraturas , Osteonecrose/cirurgia , Parafusos Pediculares , Doenças da Coluna Vertebral/cirurgia , Idoso , Cimentos Ósseos/efeitos adversos , Feminino , Fixação Interna de Fraturas/efeitos adversos , Humanos , Masculino , Osteonecrose/patologia , Parafusos Pediculares/efeitos adversos , Doenças da Coluna Vertebral/patologia , Resultado do Tratamento
7.
World Neurosurg ; 121: e404-e410, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30266711

RESUMO

BACKGROUND: A high rate of instrumentation failure is frequently seen in osteoporotic spines, especially at the sacral segment because of the great shear stress. Several techniques of sacral pedicle screw placement, such as bicortical and tricortical fixation, have been developed; however, the problems of loosening and pulling out of the screws are still a concern. Recently, the polymethylmethacrylate (PMMA)-augmented pedicle screws have been shown to strengthen the purchase in osteoporotic spine, but there are few reports on the effect of S1 pedicle screw with PMMA augmentation. METHODS: Seventy-five patients receiving cement-augmented pedicle screws at lumbosacral vertebra were enrolled and divided into 3 groups by different patterns of S1 pedicle screw placement: S1 pedicle screw with PMMA augmentation (group A, 25 patients), S1 bicortical pedicle screw fixation (group B, 25 patients), and S1 tricortical pedicle screw fixation (group C, 25 patients). The Visual Analogue Scale (VAS) and Oswestry Disability Index (ODI) scores were assessed preoperatively and at the last follow-up. Besides, the complications, loosening rate, and fusion rate were recorded. RESULTS: The VAS and ODI scores at the last follow-up were significantly improved in the 3 groups compared with preoperative results. Better pain relief and functional improvement at the last follow-up was seen in group A compared with the other 2 groups; however, no significant difference was detected between groups B and C. Although the lowest screws loosening rates and the highest fusion rate were found in group A, no significant difference among these 3 groups. Furthermore, longer fusion segments and larger postoperative pelvic incidence-lumbar lordosis (PL-LL) were found as risks related to S1 screw loosening without cement augmentation. CONCLUSIONS: The S1 pedicle screws with PMMA augmentation achieved better stability with less screw loosening in the osteoporotic spine with lumbosacral degenerative diseases compared with bicortical/tricortical fixation at S1. This procedure is especially recommended for patients with long segment fixation and large postoperative PI-LL, but there is also a risk of bone cement leakage and a learning curve.


Assuntos
Região Lombossacral/cirurgia , Doenças Neurodegenerativas/complicações , Doenças Neurodegenerativas/cirurgia , Osteoporose/complicações , Parafusos Pediculares , Polimetil Metacrilato/uso terapêutico , Fusão Vertebral/métodos , Idoso , Idoso de 80 Anos ou mais , Cimentos Ósseos/uso terapêutico , Estudos de Coortes , Feminino , Humanos , Região Lombossacral/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Radiografia , Fusão Vertebral/instrumentação , Escala Visual Analógica
8.
J Orthop Surg Res ; 14(1): 170, 2019 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-31171020

RESUMO

PURPOSE: To compare the safety and efficiency of cement-augmented pedicle screw with traditional pedicle screw technique applied on the patients in the osteoporotic spine with lumbar degenerative diseases. METHODS: Fifty-six patients followed up at least 2 years were enrolled in our institute with retrospectively reviewed from January 2009 to June 2014, diagnosed as lumbar spondylolisthesis, or lumbar stenosis, with T score ≤- 2.5 SD of BMD, and received less than three-segment PLIF or TLIF. All patients were divided into 2 groups: 28 (2 males, 26 females) in polymethylmethacrylate-augmented pedicle screw group (PSA) group, the other 28 (3 males, 25 females) in traditional pedicle screw group (TPS). Surgical data including the operation time, intra-operative blood loss, hospitalization day and surgical complications were recorded, as well as the radiological parameters measured from the postoperative X-rays and CT scans containing the rates of fusion, screw loosening, and cage subsidence incidence. In addition, the visual analog scores (VAS) and Oswestry Disability Index (ODI) were evaluated preoperatively and postoperatively. RESULTS: The average follow-up period was 34.32 months (ranging from 24 months to 51 months). Compared with PSA group, operation time and average hospital stay in the TPS group decreased significantly (P < 0.05). While no statistical difference for blood loss between 2 groups (P > 0.05). At 2 years postoperation, from CT-scans, 2/172 screws loosening and 1/56 segment non-union occurred in PSA group, with significantly lower incidence than those in TPS group (8/152 screws loosening and 6/50 segments non-union occurred, P < 0.05). Regarding the cage subsidence, 24 segments found height loss (5.30 ± 1.92 mm) in PSA group without difference compared with that of 19 segments (4.78 ± 1.37 mm) in TPS group (P > 0.05). Besides, the number and the location of cages and the leakage of the cement were found out little related with the subsidence in the PSA group (P > 0.05). After surgeries, VAS and ODI at 1 month, 6 months, 12 months, and last follow-up improved significantly in two groups (P < 0.05). There were no significant differences in VAS and ODI preoperatively and postoperatively between 2 groups (P > 0.05). In addition, eight patients with asymptomatic trajectory PMMA leakages were detected. CONCLUSION: Cement-augmented pedicle screw technique is effective and safe in the osteoporotic spine with lumbar degenerative diseases, with better fusion rates and less screw loosening incidence. There is no difference in the fusion rate and loosening rate between the two groups in the single segment patients; however, there are better fusion rate and lower pedicle screw loosening rate of the PSA group in the double or multiple group patients.


Assuntos
Degeneração do Disco Intervertebral/cirurgia , Vértebras Lombares/cirurgia , Osteoporose/cirurgia , Parafusos Pediculares/tendências , Idoso , Cimentos Ósseos/uso terapêutico , Feminino , Humanos , Degeneração do Disco Intervertebral/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Osteoporose/diagnóstico por imagem , Parafusos Pediculares/normas , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA