Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Oral Maxillofac Surg ; 20(1): 85-90, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26563099

RESUMO

OBJECTIVES: This paper aims to evaluate in vitro the mechanical and microstructural properties of internal fixation systems used in oral and maxillofacial surgeries. MATERIALS AND METHODS: Four brands of internal fixation systems (screws and 4-hole straight plates) were selected and assigned to four groups: G1 Leibinger®, G2 Tóride®, G3 Engimplan®, and G4 Medartis®. The systems were submitted to Vickers hardness testing, metallographic and interstitial elements chemical composition analyses. Data were submitted to ANOVA and Tukey's test for statistical analysis. RESULTS: Plates in groups 1, 2, and 3 showed similar microstructure and mechanical properties, different from those in G4 revealing larger grains. In all groups, the screws showed similar microstructure, with uniform arrangement and size of grains; the screws showed higher hardness values than those observed for the plates. CONCLUSIONS: The results indicate that all materials tested are adequate for use in oral maxillofacial surgeries.


Assuntos
Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Testes de Dureza , Teste de Materiais , Procedimentos Cirúrgicos Bucais/instrumentação , Humanos , Técnicas In Vitro , Nitrogênio/análise , Imagem Óptica , Oxigênio/análise
2.
Acta Cir Bras ; 29(9): 579-87, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25252204

RESUMO

PURPOSE: To investigate the osseointegration properties of prototyped implants with tridimensionally interconnected pores made of the Ti6Al4V alloy and the influence of a thin calcium phosphate coating. METHODS: Bilateral critical size calvarial defects were created in thirty Wistar rats and filled with coated and uncoated implants in a randomized fashion. The animals were kept for 15, 45 and 90 days. Implant mechanical integration was evaluated with a push-out test. Bone-implant interface was analyzed using scanning electron microscopy. RESULTS: The maximum force to produce initial displacement of the implants increased during the study period, reaching values around 100N for both types of implants. Intimate contact between bone and implant was present, with progressive bone growth into the pores. No significant differences were seen between coated and uncoated implants. CONCLUSION: Adequate osseointegration can be achieved in calvarial reconstructions using prototyped Ti6Al4V Implants with the described characteristics of surface and porosity.


Assuntos
Cerâmica/uso terapêutico , Implantes Experimentais , Osseointegração/fisiologia , Crânio/cirurgia , Titânio/uso terapêutico , Animais , Fosfatos de Cálcio , Cerâmica/química , Materiais Revestidos Biocompatíveis , Masculino , Teste de Materiais , Microscopia Eletrônica de Varredura , Ratos Wistar , Reprodutibilidade dos Testes , Espectrometria por Raios X , Propriedades de Superfície , Fatores de Tempo , Titânio/química , Resultado do Tratamento
3.
Acta cir. bras ; 29(9): 579-587, 09/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-722127

RESUMO

PURPOSE: To investigate the osseointegration properties of prototyped implants with tridimensionally interconnected pores made of the Ti6Al4V alloy and the influence of a thin calcium phosphate coating. METHODS: Bilateral critical size calvarial defects were created in thirty Wistar rats and filled with coated and uncoated implants in a randomized fashion. The animals were kept for 15, 45 and 90 days. Implant mechanical integration was evaluated with a push-out test. Bone-implant interface was analyzed using scanning electron microscopy. RESULTS: The maximum force to produce initial displacement of the implants increased during the study period, reaching values around 100N for both types of implants. Intimate contact between bone and implant was present, with progressive bone growth into the pores. No significant differences were seen between coated and uncoated implants. CONCLUSION: Adequate osseointegration can be achieved in calvarial reconstructions using prototyped Ti6Al4V Implants with the described characteristics of surface and porosity. .


Assuntos
Animais , Masculino , Cerâmica/uso terapêutico , Implantes Experimentais , Osseointegração/fisiologia , Crânio/cirurgia , Titânio/uso terapêutico , Fosfatos de Cálcio , Materiais Revestidos Biocompatíveis , Cerâmica/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Ratos Wistar , Reprodutibilidade dos Testes , Espectrometria por Raios X , Propriedades de Superfície , Fatores de Tempo , Resultado do Tratamento , Titânio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA