Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Molecules ; 28(22)2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-38005196

RESUMO

In view of the serious side effects of chlortetracycline (CTC) on the human body, it is particularly important to develop rapid, sensitive, and selective technologies for the detection of CTC in food. In this work, a molecularly imprinted electrochemical sensor with [Fe(CN)6]3-/4- as signal probe was proposed for the highly sensitive and selective detection of CTC. For this purpose, TiO2, which acts as an interlayer scaffold, was uniformly grown on the surface of Ti3C2Tx sheets through a simple two-step calcination process using Ti3C2Tx as the precursor to effectively avoid the stacking of Ti3C2Tx layers due to hydrogen bonding and van der Waals forces. This endowed TiO2@Ti3C2Tx with large specific surface, abundant functional sites, and rapid mass transfer. Then, polypyrrole molecularly imprinted polymers (MIPs) with outstanding electrical conductivity were modified on the surface of TiO2@Ti3C2Tx via simple electro-polymerization, where the pyrrole was employed as a polymeric monomer and the CTC provided a source of template molecules. This will not only provide specific recognition sites for CTC, but also facilitate electron transport on the electrode surface. The synergistic effects between TiO2@Ti3C2Tx and polypyrrole MIPs afforded the TiO2@Ti3C2Tx/MIP-based electrochemical sensor excellent detection properties toward CTC, including ultra-low limits of detection (LOD) (0.027 nM), a wide linear range (0.06-1000 nM), and outstanding stability, reproducibility, selectivity, and feasibility in real samples. The results indicate that this strategy is feasible and will broaden the horizon for highly sensitive and selective detection of CTC.


Assuntos
Clortetraciclina , Grafite , Impressão Molecular , Humanos , Polímeros/química , Titânio , Impressão Molecular/métodos , Grafite/química , Técnicas Eletroquímicas/métodos , Reprodutibilidade dos Testes , Pirróis/química , Limite de Detecção , Polímeros Molecularmente Impressos , Eletrodos
2.
J Biomed Mater Res B Appl Biomater ; 105(6): 1594-1601, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-27126379

RESUMO

Membranes with zeolites are promising for performing blood dialysis because zeolites can eliminate uremic toxins through molecular sieving. Although the size and the shape of zeolite particles can potentially influence the performance of the membranes with respect of creatinine uptake level, it is not clear what sizes and shapes lead to better performance. In this paper, we carry out experiments to answer this question. Spherical microparticle 840, spherical nanoparticle P-87 and rod-like nanoparticle P-371 zeolites were chosen to be used in all the experiments. Their creatinine uptake levels were first measured as powders in creatinine solutions with different concentrations, volumes and adsorption times. Then, nanofibrous membranes with zeolites were electrospun and their ability to adsorb creatinine was measured and compared against their respective powders' creatinine uptake level. The experiment shows that the zeolites have similar creatinine uptake ability as powders. However, they have significantly different creatinine uptake ability after being incorporated inside the membranes. Spherical microparticle 840 in the membrane presented the best creatinine uptake ability, at 8957 µg g-1 , which was half of its powders'. On the other hand, P-87 presented largely decreased, while P-371 presented even lower creatinine uptake ability in membranes when compared to respective powders'. The results shows that microparticle and sphere shaped particles perform better inside the membranes. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1594-1601, 2017.


Assuntos
Membranas Artificiais , Nanopartículas/química , Toxinas Biológicas/química , Zeolitas/química , Adsorção , Creatinina/química , Tamanho da Partícula
3.
Biosens Bioelectron ; 62: 261-7, 2014 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-25022509

RESUMO

Most conducting polymer/graphene composites have excellent electrical conductivity. However, the background currents of these composites modified electrodes are much larger. In order to improve the sensitivities of these methods, it is necessary to decrease the background signal. In this paper, porous structure films of overoxidized polypyrrole/graphene (PPyox/GR) have been electrochemically coated onto glassy carbon electrode (GCE) and successfully utilized as an efficient electrode material for the quantitive detection of adenine and guanine, two of the most important components of DNA and RNA. The permselective polymer coatings with low background current could improve the selectivity and sensitivity of microelectrodes for the electropositive purine bases. The GRs into these polymers would further improve sensitivity by increasing the electroactive surface area. The electrochemical sensor can be applied to the quantification of adenine and guanine with a linear range covering 0.06-100 µM and 0.04-100 µM, and a low detection limit of 0.02 µM and 0.01 µM, respectively. More importantly, the proposed method was applied to quantify adenine and guanine in calf thymus DNA with satisfactory results.


Assuntos
Adenina/análise , Técnicas Biossensoriais/métodos , Guanina/análise , Nanocompostos , Animais , Técnicas Biossensoriais/estatística & dados numéricos , Bovinos , DNA/química , Técnicas Eletroquímicas , Eletrodos , Grafite/química , Concentração de Íons de Hidrogênio , Limite de Detecção , Microscopia Eletrônica de Varredura , Nanocompostos/química , Nanocompostos/ultraestrutura , Oxirredução , Polímeros/química , Pirróis/química , Reprodutibilidade dos Testes , Espectroscopia de Infravermelho com Transformada de Fourier
4.
Biosens Bioelectron ; 50: 244-50, 2013 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-23871872

RESUMO

Herein, functionalized PEDOT films were prepared by incorporation of two electroactive species, ferrocenecarboxylic acid (Fc(-)) and ferricyanide (Fe(CN)6(4-)) as doping anions during the electropolymerization of PEDOT at glassy carbon electrodes (GCEs) from aqueous solution. The electrochemically synthesized electroactive species-doped PEDOT films have been carefully characterized by scanning electron microscopy (SEM), FTIR and UV/Vis spectra and various electrochemical techniques. Such nanostructured films combined the advantages of PEDOT (high conductivity and stability) together with electroactive species (good electrochemical activity) and were applied as electrochemical sensors for simultaneous determination of vitamin B2 (VB2), vitamin B6 (VB6) and vitamin C (VC). The results showed that the oxidation peak currents of vitamins obtained at the GCEs modified with electroactive species-doped PEDOT films were much higher than those at the ClO4(-)-doped PEDOT films and bare GCEs. The experiment results also illustrated that the sensors possessed high selectivity with no interference from other potential competing species. Moreover, the proposed sensors were successfully employed for the determination of vitamins in orange juice samples with satisfactory results.


Assuntos
Ácido Ascórbico/análise , Bebidas/análise , Compostos Bicíclicos Heterocíclicos com Pontes/química , Técnicas Eletroquímicas/instrumentação , Polímeros/química , Riboflavina/análise , Vitamina B 6/análise , Citrus sinensis/química , Eletrodos , Ferricianetos/química , Compostos Ferrosos/química , Metalocenos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA