Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Implant Dent ; 26(5): 744-750, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28945670

RESUMO

OBJECTIVES: To investigate whether a different implant geometry with the same potential contact surface area (PCSA) affects the principal stress and strains in bone. MATERIAL AND METHODS: Three-dimensional finite-element models were created with a single endosseous implant embedded in bone. The irregular (IR) dental root-analog implant and regular (R) cylindrical implant with the same PCSA 350 mm were modeled, keeping the size of the thinnest implant wall 0.8 mm, and the thinnest bone wall 1 mm. The regular or irregular abutments were either 4.5 mm lower than the platform of the implants or 5 mm higher than the platform of the implants, both with the taper 1.44°. A 100 N vertical or 100 N vertical/50 N horizontal occlusal loading was applied. The biomechanical behaviors of periimplant bone were recorded. RESULTS: The IR implant design experienced lower periimplant stress and strain under oblique loading than that of R implant design. In the IR implant design, comparable stress in bone, implant, and abutment were found under 100 N vertical loading or 100 N vertical/50 N horizontal loading. In the R implant design, much higher stress in bone, implant, and abutment were found under 100 N vertical/50 N horizontal loading than that under 100 N vertical loading. CONCLUSION: Irregular dental root-analog implant is a biomechanically favorable design principle for decreasing periimplant stress and strain under oblique loading.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Processo Alveolar/fisiologia , Materiais Biomédicos e Odontológicos , Implantação Dentária Endóssea/efeitos adversos , Implantes Dentários/efeitos adversos , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Humanos , Modelos Biológicos , Estresse Mecânico
2.
Implant Dent ; 25(6): 802-806, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27755176

RESUMO

OBJECTIVE: The aim of this study was to evaluate cross-sectional area of the abutments, strain distribution in the periimplant bone, stress in the abutments and dental root-analog implant by different abutment design under different loading conditions, through three-dimensional finite element analysis. METHODS: Two three-dimensional finite element models were established. Two types of abutments, oval cross section abutment (OCSA) and circular cross section abutment (CCSA) were designed, keeping the size of the thinnest implant wall 0.75 mm. Two types of load were applied to the abutment in each model: 100 N vertical load (V), 100 N vertical/50 N horizontal load (VH). The biomechanical behaviors of abutments, implants, and periimplant bone were recorded. RESULTS: The cross-section area of OCSA is 36.5% larger than that of CCSA. In implants, the maximum von Mises stress value in OCSA design was 24.6% lower than that in CCSA design under V and under VH. In abutments, the maximum von Mises stress value in OCSA design was 40.0% lower than that in CCSA design under V, the maximum von Mises stress value in OCSA design was 12.2% lower than that in CCSA design under VH. CONCLUSIONS AND CLINICAL SIGNIFICANCE: The irregular design offers advantages over regular design.


Assuntos
Projeto do Implante Dentário-Pivô , Implantação Dentária Endóssea , Implantes Dentários , Raiz Dentária/cirurgia , Fenômenos Biomecânicos , Dente Suporte , Análise do Estresse Dentário , Análise de Elementos Finitos , Humanos , Estresse Mecânico , Suporte de Carga
3.
Int J Mol Sci ; 16(10): 24946-64, 2015 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-26492241

RESUMO

A plastic and biodegradable bone substitute consists of poly (L-lactic-co-glycolic) acid and 30 wt % ß-tricalcium phosphate has been previously fabricated, but its osteogenic capability required further improvement. We investigated the use of globular adiponectin (gAPN) as an anabolic agent for tissue-engineered bone using this scaffold. A qualitative analysis of the bone regeneration process was carried out using µCT and histological analysis 12 weeks after implantation. CBCT (Cone Beam Computed Tomography) superimposition was used to characterise the effect of the different treatments on bone formation. In this study, we also explored adiponectin's (APN) influence on primary cultured human jaw bone marrow mesenchymal stem cells gene expressions involved in the osteogenesis. We found OPEN ACCESS Int. J. Mol. Sci. 2015, 16 24947 that composite scaffolds loaded with gAPN or bone morphogenetic protein 2 (BMP2) exhibited significantly increased bone formation and mineralisation following 12 weeks in the extraction sockets of beagle dogs, as well as enhanced expression of osteogenic markers. In vitro investigation revealed that APN also promoted osteoblast differentiation of primary cultured human jaw bone marrow mesenchymal stem cells (h-JBMMSCs), accompanied by increased activity of alkaline phosphatase, greater mineralisation, and production of the osteoblast-differentiated genes osteocalcin, bone sialoprotein and collagen type I, which was reversed by APPL1 siRNA. Therefore, the composite scaffold loaded with APN exhibited superior activity for guided bone regeneration compared with blank control or Bio-Oss® (a commercially available product). The composite scaffold with APN has significant potential for clinical applications in bone tissue engineering.


Assuntos
Adiponectina/farmacologia , Osteogênese/efeitos dos fármacos , Proteínas Adaptadoras de Transdução de Sinal/metabolismo , Adiponectina/química , Animais , Proteína Morfogenética Óssea 2/metabolismo , Regeneração Óssea/efeitos dos fármacos , Fosfatos de Cálcio/química , Diferenciação Celular/efeitos dos fármacos , Cães , Masculino , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Engenharia Tecidual , Alicerces Teciduais/química
4.
Chin Med J (Engl) ; 129(12): 1464-70, 2016 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-27270544

RESUMO

BACKGROUND: The accuracy of three-dimensional (3D) reconstructions from cone-beam computed tomography (CBCT) has been particularly important in dentistry, which will affect the effectiveness of diagnosis, treatment plan, and outcome in clinical practice. The aims of this study were to assess the linear, volumetric, and geometric accuracy of 3D reconstructions from CBCT and to investigate the influence of voxel size and CBCT system on the reconstructions results. METHODS: Fifty teeth from 18 orthodontic patients were assigned to three groups as NewTom VG 0.15 mm group (NewTom VG; voxel size: 0.15 mm; n = 17), NewTom VG 0.30 mm group (NewTom VG; voxel size: 0.30 mm; n = 16), and VATECH DCTPRO 0.30 mm group (VATECH DCTPRO; voxel size: 0.30 mm; n = 17). The 3D reconstruction models of the teeth were segmented from CBCT data manually using Mimics 18.0 (Materialise Dental, Leuven, Belgium), and the extracted teeth were scanned by 3Shape optical scanner (3Shape A/S, Denmark). Linear and volumetric deviations were separately assessed by comparing the length and volume of the 3D reconstruction model with physical measurement by paired t- test. Geometric deviations were assessed by the root mean square value of the imposed 3D reconstruction and optical models by one-sample t-test. To assess the influence of voxel size and CBCT system on 3D reconstruction, analysis of variance (ANOVA) was used (µ = 0.05). RESULTS: The linear, volumetric, and geometric deviations were -0.03 ± 0.48 mm, -5.4 ± 2.8%, and 0.117 ± 0.018 mm for NewTom VG 0.15 mm group; -0.45 ± 0.42 mm, -4.5 ± 3.4%, and 0.116 ± 0.014 mm for NewTom VG 0.30 mm group; and -0.93 ± 0.40 mm, -4.8 ± 5.1%, and 0.194 ± 0.117 mm for VATECH DCTPRO 0.30 mm group, respectively. There were statistically significant differences between groups in terms of linear measurement (P < 0.001), but no significant difference in terms of volumetric measurement (P = 0.774). No statistically significant difference were found on geometric measurement between NewTom VG 0.15 mm and NewTom VG 0.30 mm groups (P = 0.999) while a significant difference was found between VATECH DCTPRO 0.30 mm and NewTom VG 0.30 mm groups (P = 0.006). CONCLUSIONS: The 3D reconstruction from CBCT data can achieve a high linear, volumetric, and geometric accuracy. Increasing voxel resolution from 0.30 to 0.15 mm does not result in increased accuracy of 3D tooth reconstruction while different systems can affect the accuracy.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Dente/anatomia & histologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Dente/patologia
5.
Comput Biol Med ; 43(11): 1949-54, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24209940

RESUMO

Three-dimensional (3D) finite element models of a posterior mandibular segment and a distraction implant (DI) were created and assembled in this study. The diameter of distraction screw (DS) was set as input variable, ranging from 1.0 to 3.0mm, to analyze the stress and displacement, in order to obtain an optimal outcome of the DI. The results indicate that when the diameter of DS was 2.0mm, the stresses in jaw bone and DS and the displacement of DS reached a relatively low range. The diameter of DS significantly affects the stress distribution in DI and surrounding bone. The present study demonstrates that from clinical and biomechanical points of view, the optimal diameter of DS is 2.0mm.


Assuntos
Fenômenos Biomecânicos/fisiologia , Desenho Assistido por Computador , Implantes Dentários , Planejamento de Prótese Dentária/métodos , Parafusos Ósseos , Análise de Elementos Finitos , Humanos , Mandíbula/fisiologia , Modelos Dentários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA