Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 72: 237-243, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32891741

RESUMO

BACKGROUND: The aim of this study was to evaluate the efficacy and safety of a novel self-expanding nitinol stent (Smartflex stent) in femoropopliteal artery obliterans disease. METHODS: From June 2016 to May 2019, patients with atherosclerotic occlusion disease of the superficial femoral and popliteal arteries using the Smartflex stents were retrospectively analyzed in our institution. Patients were monitored at 1, 3, 6, and 12 months and annually thereafter. The main characteristics of the diseased vessels, perioperative and follow-up outcome were evaluated. Kaplan-Meier method was used to assess patency rate and the rate of freedom from clinically driven target lesion revascularization (CD-TLR). RESULTS: A total of 50 limbs from 48 patients (mean age 69.4 ± 8.95 years; 38 men) were included. Eighty-eight Smartflex stents (1.76 stents per limb) were deployed successfully. Of the study patients, 82% had claudication (Rutherford III), 10% had rest pain (Rutherford IV), and 8% had tissue loss (Rutherford V). Trans-Atlantic Inter-Society Consensus II C and D lesions were 26% and 42%, respectively. The mean lesion length was 18.2 ± 8.5 cm and the mean stented length was 22.3 ± 9.9 cm. The average follow-up time was 16.4 ± 8.2 months. Of these lesions, 42 (94%) were chronic total occlusions and 16 (32%) were severely calcified. The primary patency rate at 1 year per Kaplan-Meier estimating, the rate of freedom from CD-TLR at 1 year, and the second patency rate was 83.3%, 88.1%, and 94%, respectively. Among them, 90% patients had improved ankle-brachial indexes (0.47 ± 0.13 before and 0.84 ± 0.16 after). No stent fractures and kinking were identified. CONCLUSIONS: Stenting of the femoropopliteal artery diseases using the Smartflex stent appeared to be safe and effective. It performed well in long-segment and above knee joint lesions.


Assuntos
Ligas , Arteriosclerose Obliterante/terapia , Procedimentos Endovasculares/instrumentação , Artéria Femoral , Artéria Poplítea , Stents Metálicos Autoexpansíveis , Idoso , Arteriosclerose Obliterante/diagnóstico por imagem , Arteriosclerose Obliterante/fisiopatologia , Procedimentos Endovasculares/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA