RESUMO
Dental implants with different primary stabilities give rise to distinct stress distributions at the implant-bone interface after placement and exert mechanical force on the cells in the bone tissue. This study aimed to investigate whether the mechanical forces in peri-implant bone participate in the body's immune response and influence macrophage polarization. Therefore, an in vivo rat implantation model with different primary implant stabilities was established. The osteoimmune response and macrophage polarization were investigated, and the osseointegration of the implants was evaluated. In an in vitro experiment, an external compressive force was applied to RAW264.7 cells, and the polarization phenotype was observed. MC3T3-E1 cells were cultured in macrophage-conditioned medium to investigate the regulatory effect of the macrophage-secreted cytokines on the osteogenic differentiation of osteoblasts. In vivo experimental results indicated that the primary stability of implants is positively correlated with the mechanical force. The osteoimmune response was significantly amplified by compressive force generated from implants. This compressive force first induced both M1 and M2 macrophage polarization and then accelerated the progression of the transition to M2 macrophages in the bone repair phase. In vitro, compressive force significantly upregulated the M1 and M2 macrophage polarization. In addition, the suppressive effect of macrophages on the osteogenesis of MC3T3 cells was relieved by cytokines secreted by macrophages under compressive force loading, which promoted their osteogenesis. Overall, these results clarify that compressive force from different primary stabilities is an important influencing factor regulating the osteoimmunne response and macrophage polarization in addition to maintaining the implant.
RESUMO
This study investigated the properties of the micro/nano composite structure on the surface of high oxygen concentration titanium (HOC-Ti) after anodic oxidation modification (HOC-NT) and evaluated its biocompatibility as a dental implant material in vitro and in vivo. HOC-Ti was produced by titanium powders and rutile powders using the powder metallurgy method. Its surface was modified by anodic oxidation. After detecting the electrochemical characteristics, the surface properties of HOC-NT were investigated. MC3T3 and MLO-Y4 cells were employed to evaluate the biocompatibility of HOC-NT and cocultured to study the effects of the changes in osteocytes induced by HOC-NT on osteoblasts. While, its possible mechanism was investigated. In addition, osseointegration around the HOC-NT implant was investigated through in vivo experiments. The results showed that a unique micronano composite structure on the HOC-Ti surface with excellent hydrophilicity and suitable surface roughness was created after anodic oxidation promoted by its electrochemical characteristics. The YAP protein may play an important role in regulating bone remodeling by ß-catenin and Rankl/OPG Signaling Pathways. An in vivo study also revealed an accelerated formation rate of new bone and more stable osseointegration around the HOC-NT implant. In view of all experimental results, it could be concluded that the unique morphology of HOC-NT has enhanced physicochemical and biological properties. The promotion of bone formation around implants indicated the feasibility of HOC-NT for applications in oral implants.
Assuntos
Nanocompostos , Osteogênese , Titânio/farmacologia , Osseointegração/fisiologia , Oxigênio/farmacologiaRESUMO
In order to improve the strength of commercially pure Ti (CP-Ti) for oral implants, the high oxygen content Ti (HOC-Ti) was prepared via powder metallurgy. Its composition and mechanical properties were then characterized. After surface treatment by sandblasting and acid etching (SLA), the surface morphology, wettability and roughness of the HOC-Ti and CP-Ti sample were examined. In an in vitro test that followed an evaluation of the protein adsorption capacity of HOC-Ti, the mouse preosteoblast cells were inoculated onto the specimens to evaluate their biocompatibility, in comparison with those of CP-Ti. The oxygen concentration of the HOC-Ti increased to 0.62 wt%, which is higher than the 0.26 wt% of the CP-Ti, while their compositions and microstructures were very similar. The tensile and compressive yield strength of the HOC-Ti (800 MPa) was improved significantly in comparison to that of the CP-Ti (530 MPa). After surface treatment, a unique structure of micropores with a diameter of 380 nm was observed on the entire surface of the HOC-Ti that facilitates cell adhesion and proliferation. The wettability of the HOC-Ti was obviously superior (p < 0.05). The in vitro study showed that the MC3T3-E1 cells inoculated on the surface of HOC-Ti exhibited a homogeneous microstructure, and the viability was higher than that of the control group on days 4 and 7 (p < 0.05). In addition, the number and differentiation activity of cells that adhered to the surface of the HOC-Ti increased significantly on day 7 (p < 0.05). The experimental results showed that, in view of its mechanical properties and biocompatibility, HOC-Ti is superior to CP-Ti and is promising for oral implant applications.
Assuntos
Implantes Dentários , Titânio , Animais , Teste de Materiais , Camundongos , Oxigênio , Propriedades de SuperfícieRESUMO
Dental implant may suffer transient external impacts. To simulate the effect of impact forces on bone damage is very important for evaluation of damage and guiding treatment in clinics. In this study, an animal model was established by inserting an implant into the femoral condyle of New Zealand rabbit. Implant with good osseointegration was loaded with impact force. A three-dimensional finite element model was established based on the data of the animal model. Damage process to bone tissue was simulated with Abaqus 6.13 software combining dynamic mechanical properties of the femur. The characteristics of bone damage were analyzed by comparing the results of animal testing with numerical simulation data. After impact, cortical bone around the implant and trabecular at the bottom of the implant were prone to damage. The degree of damage correlated with the direction of loading and the magnitude of the impact. Lateral loading was most likely performed to damage cancellous bone. The stress wave formed by the impact force can damage the implant-bone interface and peri-implant trabeculae. The data from numerical simulations were consistent with data from animal experiments, highlighting the importance of a thorough examination and evaluation based on the patient's medical history.
Assuntos
Osso e Ossos/patologia , Simulação por Computador , Implantes Dentários , Animais , Fenômenos Biomecânicos , Osso Cortical/diagnóstico por imagem , Osso Cortical/patologia , Fêmur/patologia , Fêmur/fisiopatologia , Análise de Elementos Finitos , Osseointegração , Osteogênese , Implantação de Prótese , Coelhos , Suporte de Carga , Microtomografia por Raio-XRESUMO
This study investigated the surface characteristics and biocompatibility of ultrafine-grain pure titanium (UFG Ti) after sandblasting and acid etching (SLA) treatment to determine an effective method for modification of UFG Ti dental implants. The UFG Ti was processed by equal-channel angular pressing (ECAP). The micromorphology, roughness, and wettability of its surface were studied after SLA modification in different conditions. Rat bone marrow mesenchymal stem cells were subsequently seeded onto the specimens to evaluate the biocompatibility of cell adhesion, proliferation, and differentiation compared with commercially pure titanium (CP Ti). The results showed that surface characteristics of UFG Ti were affected by the pressure of sandblasting and acid etching time in addition to material properties. The favorable hierarchical porous structure that would benefit cell adhesion was formed on the UFG Ti surface when the pressure of sandblasting was 0.6 MPa and the acid etching time was 5 min; at this time, UFG Ti promoted proliferation and differentiation to a greater extent than CP Ti because of its excellent wettability. From this study, it could be seen that UFG Ti can be used as a dental implant material after proper surface modification.
RESUMO
A versatile strategy to endow dental implants with long-term antibacterial ability without compromising the cytocompatibility is highly desirable to combat implant-related infection. Silver nanoparticles (Ag NPs) have been utilized as a highly effective and broad-spectrum antibacterial agent for surface modification of biomedical devices. However, the high mobility and subsequent hazardous effects of the particles on mammalian cells may limit its practical applications. Thus, Ag NPs were immobilized on the surface of sand-blasted, large grit, and acid-etched (SLA) titanium by manipulating the atomic-scale heating effect of silver plasma immersion ion implantation. The silver plasma immersion ion implantation-treated SLA surface gave rise to both good antibacterial activity and excellent compatibility with mammalian cells. The antibacterial activity rendered by the immobilized Ag NPs was assessed using Fusobacterium nucleatum and Staphylococcus aureus, commonly suspected pathogens for peri-implant disease. The immobilized Ag NPs offered a good defense against multiple cycles of bacteria attack in both F. nucleatum and S. aureus, and the mechanism was independent of silver release. F. nucleatum showed a higher susceptibility to Ag NPs than S. aureus, which might be explained by the presence of different wall structures. Moreover, the immobilized Ag NPs had no apparent toxic influence on the viability, proliferation, and differentiation of rat bone marrow mesenchymal stem cells. These results demonstrated that good bactericidal activity could be obtained with very small quantities of immobilized Ag NPs, which were not detrimental to the mammalian cells involved in the osseointegration process, and promising for titanium-based dental implants with commercial SLA surfaces.