Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Biol Macromol ; 164: 1949-1959, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-32791272

RESUMO

Gelatine is a biocompatible and natural polymer with chemical properties similar to the extracellular matrix. However, it has poor mechanical properties and sensitive to enzymatic biodegradation that limits its application in 3D scaffold fabrication. Cellulose nanofibrous (CNF) offers biocompatibility, high surface area and excellent mechanical properties with slow in-vivo degradation. To fine tune their properties, CNF, and gelatine (CNF-GEL) were blended to form biocomposite aerogels. Epichlorohydrin (EPH) was incorporated into CNF-GEL as a chemical crosslinker to investigate its effect on the physiochemical, mechanical, and biological properties of the biocomposite aerogels both in-vitro and in-vivo. Regardless of the composition of the prepared aerogels, they possessed porosity of >90% with the pore size of 7-135 µm, which was confirmed in the morphological analysis. The presence of EPH improved the chemical interaction between CNF and gelatine, hence enhanced the compressive strength compared to uncrosslinked samples. The formulation of crosslinked CNF-GEL 90:10 offered the highest compressive strength of 61.35 kPa. The in-vitro and in-vivo studies showed adequate cytocompatibility, cell viability and cell attachment in the optimal crosslinked formulation with tuned enzymatic degradation. Antimicrobial property was also achieved in the optimal scaffold by incorporating curcumin as an antimicrobial agent.


Assuntos
Materiais Biocompatíveis/química , Celulose/química , Gelatina/química , Nanofibras/química , Alicerces Teciduais/química , Animais , Materiais Biocompatíveis/farmacologia , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Celulose/farmacologia , Força Compressiva/efeitos dos fármacos , Epicloroidrina/química , Gelatina/farmacologia , Humanos , Masculino , Polímeros/química , Porosidade , Ratos , Ratos Sprague-Dawley , Engenharia Tecidual/métodos
2.
J Nanosci Nanotechnol ; 9(12): 7181-5, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19908753

RESUMO

The novelty of this study resides in the fabrication of a bio-sensing device, based on the surface acoustic wave (SAW) on a nanocrystalline ZnO film. The ZnO film was deposited using an rf magnetron sputtering at room temperature on silicon. The deposited films showed the c-axis-oriented crystallite with grain size of approximately 40 nm. The immunosensing device was fabricated using photolithographic protocols on the film. As a model biomolecular recognition and immunosensing, biospecific interaction between a 6-(2,4-dinitrophenyl)aminohexanoic acid (DNP) antigen and its antibody was employed, demonstrating the shifts of resonant frequencies on SAW immunosensing device. The device exhibited a linearity as a function of the antibody concentration in the range of 20-20,000 ng/ml.


Assuntos
Acústica/instrumentação , Técnicas Biossensoriais/instrumentação , Imunoensaio/instrumentação , Sistemas Microeletromecânicos/instrumentação , Nanoestruturas/química , Silício/química , Óxido de Zinco/química , Cristalização/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Membranas Artificiais , Nanoestruturas/ultraestrutura , Nanotecnologia/instrumentação , Propriedades de Superfície
3.
Adv Healthc Mater ; 8(15): e1801649, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31168937

RESUMO

Medical implantation of an electrocorticography (ECoG) recording system for brain monitoring is an effective clinical tool for seizure focus location and brain disease diagnosis. Planar and flexible ECoG electrodes can minimize the risks of infection and serious inflammatory response, and their good shape adaptability allows the device to fit complex cortex shape and structure to record brain signals with high spatial and temporal resolution. However, these ECoG electrodes require an additional surgery to remove the implant, which imposes potential medical risks. Here, a novel flexible and bioresorbable ECoG device integrated with an intracortical pressure sensor for monitoring swelling of the cortex during operation is reported. The ECoG device is fabricated with poly(l-lactide) and polycaprolactone composite and transient metal molybdenum. In vivo tests on rats show that the ECoG system can record the dynamic changes in brain signals for the different epilepsy stages with high resolution, while the malleable pressure sensor shows a linear relationship between the pressure and resistance in in vitro tests. In vitro degradation experiments show that the ECoG system can work stably for about five days before loss of efficacy, and the whole ECoG system degrades completely in a phosphate buffer solution in about 100 days.


Assuntos
Implantes Absorvíveis , Encéfalo/fisiologia , Eletrocorticografia/métodos , Algoritmos , Animais , Eletrocorticografia/instrumentação , Eletrodos Implantados , Pressão Intracraniana , Masculino , Molibdênio/química , Poliésteres/química , Ratos , Ratos Sprague-Dawley
4.
Nanoscale ; 11(46): 22369-22377, 2019 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-31729502

RESUMO

Atomic layer deposited (ALD) ultra-thin alumina film is proposed to control the operational lifetimes of fully biodegradable (FB-) surface sensitive surface acoustic wave (SAW) devices. SAW devices encapsulated with conventional thick organic materials fail to function effectively, while devices with an ultra-thin alumina encapsulation layer (AEL) function normally with high performance. After being subjected to degradation in water, a FB-SAW device with no AEL starts to degrade immediately and fails within 8 h, due to dissolution of the tungsten electrode and piezoelectric material (ZnO). The coating of an ultra-thin AEL on the surfaces prevents SAW devices from undergoing degradation in water and enables SAW devices to perform normally before the AEL is dissolved. The stable operation lifetimes of SAW devices are linearly dependent on the AEL thickness, thus allowing for the design of devices with precisely controlled operational lifetimes and degradation times. The results show that all the materials used could be degraded; also, in vitro cytotoxicity tests indicate that the encapsulated FB-SAW devices are biocompatible, and cells can adhere and proliferate on them normally, demonstrating great potential for broader biodegradable electronic device applications.


Assuntos
Óxido de Alumínio/química , Eletrônica , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Humanos , Hidrólise , Óxidos/química , Copolímero de Ácido Poliláctico e Ácido Poliglicólico/química , Tungstênio/química , Óxido de Zinco/química
5.
ACS Appl Mater Interfaces ; 8(17): 10954-60, 2016 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-27052437

RESUMO

Egg albumen as the dielectric, and dissolvable Mg and W as the top and bottom electrodes are used to fabricate water-soluble memristors. 4 × 4 cross-bar configuration memristor devices show a bipolar resistive switching behavior with a high to low resistance ratio in the range of 1 × 10(2) to 1 × 10(4), higher than most other biomaterial-based memristors, and a retention time over 10(4) s without any sign of deterioration, demonstrating its high stability and reliability. Metal filaments accompanied by hopping conduction are believed to be responsible for the switching behavior of the memory devices. The Mg and W electrodes, and albumen film all can be dissolved in water within 72 h, showing their transient characteristics. This work demonstrates a new way to fabricate biocompatible and dissolvable electronic devices by using cheap, abundant, and 100% natural materials for the forthcoming bioelectronics era as well as for environmental sensors when the Internet of things takes off.


Assuntos
Eletrodos , Animais , Materiais Biocompatíveis , Galinhas , Eletrônica , Metais , Óvulo , Reprodutibilidade dos Testes
6.
Chemosphere ; 158: 154-62, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27262105

RESUMO

A new method for separation of 11 n-alkanes: octane, o-nonane, n-decane, n-undecane, n-dodecane, n-tridecane, n-tetradecane, n-pentdecne, n-hexadecath, heptadecane, n-octadecane in soil samples was developed. Kuderna-Danish (K.D.) concentrator enrichment prior to ultrasonic extraction and the silicone chromatography column purification and with gas chromatography flame ionization detection (GC-FID) could be used for n-alkanes determination. The micro channels of open tubular column were fabricated onto a silicon wafer to replace the quartz capillary chromatographic column. The column structure and analysis parameters that affected the column separation were investigated and optimized. Under optimal conditions, the extract reagent was centrifuged and collected. A silicone chromatography column and a K.D. concentrator were used for further clean-up and enrichment. Using this method, the limits of detection (LOD) and limits of quantification (LOQ) were obtained in the range of 0.03-0.15 and 0.1-0.5 mg kg(-1) in soil samples, respectively. The relative standard deviation (RSD) was under 12%. The optimized procedure that presented good analytical performance (with recoveries ranging from 56.5% to 89.2%), was successfully applied to determine n-alkane content in farmland soil samples adjacent to a highway. The results showed that the MWCNTs-functionalized column is capable of separating the alkane contaminations with high resolution in about 3 min, which is much shorter than that of GC-MS and other conventional analytical methods, demonstrating its great potential for rapid analysis.


Assuntos
Alcanos/análise , Cromatografia Gasosa , Cromatografia Gasosa-Espectrometria de Massas , Nanotubos de Carbono/química , Poluentes do Solo/análise , Dimetilpolisiloxanos/análise , Ionização de Chama , Limite de Detecção , Modelos Lineares , Microscopia Eletrônica de Varredura , Solo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA