RESUMO
AIM: The aim of the present study was to evaluate the effect of cement gap and drill offset on the marginal and internal fit discrepancies of crowns designed with different tooth preparations. MATERIALS AND METHODS: Five tooth preparations were constructed, and crowns with different cement gaps and drill offsets were obtained. Then, best-fit alignment was performed on the crowns with the corresponding tooth preparations, and the fit discrepancies were expressed by color-coded difference images and root mean square (RMS) values. The RMS values of each group were analyzed by the rank-based Scheirer-Ray-Hare test (α = 0.05). RESULTS: The color segments in the sharp line angles area of the Sharp line angles group changed significantly before and after the drill offset. The cement gap had a significant effect on the marginal, internal, or overall fit discrepancies of the five design groups (P < 0.001), while the drill offset had a significant effect on the marginal fit discrepancies of the Shoulder-lip group and the internal or overall fit discrepancies of the Sharp line angles group (P < 0.001). Additionally, the interaction effect between cement gap and drill offset was significant for the marginal fit discrepancies of the Shoulder-lip group and the internal or overall fit discrepancies of the Sharp line angles group (P < 0.01). CONCLUSIONS: The cement gap and drill offset had a significant adverse effect on the marginal or internal fit discrepancies of the crowns designed with the shoulder-lip and sharp line angles designs. Tooth preparation designs with intense curvature changes such as shoulder-lip and sharp line angles should be avoided clinically.
Assuntos
Coroas , Cimentos Dentários , Humanos , Cimentos de Ionômeros de Vidro , Preparo do Dente , Preparo Prostodôntico do Dente/métodos , Planejamento de Prótese Dentária , Desenho Assistido por Computador , Adaptação Marginal Dentária , Porcelana DentáriaRESUMO
PURPOSE: To evaluate the surface characteristics, accuracy (trueness and precision), and dimensional stability of tooth preparation dies fabricated using conventional gypsum and direct light processing (DLP), stereolithography (SLA), and polymer jetting printing (PJP) techniques. MATERIALS AND METHODS: Gypsum preparation dies were replicated according to the reference data and imported into DLP, SLA, and PJP printers, and the test data were obtained by scanning after 0, 1, 3, 7, 14, 28, and 42 days. After analyzing the surface characteristics, a best-fit algorithm between the test and the reference data was used to evaluate the accuracy and dimensional stability of the preparation dies. The data were analyzed by one-way analysis of variance and Tukey test or Kruskal-Wallis H test (α = .05). RESULTS: Compared with the gypsum group (3.61 ± 0.59 µm), the root mean square error (RMSE) values of the SLA group (5.33 ± 0.48 µm) was rougher (P < .05), the PJP group (2.43 ± 0.37 µm) was smoother (P < .05), and the DLP group (2.92 ± 0.91 µm) had no significant difference (P > .05). For trueness, the RMSE was greater in the PJP (34.90 ± 4.91 µm) and SLA (19.01 ± 0.95 µm) groups than in the gypsum (16.47 ± 0.47 µm) group (P < .05), and no significant difference was found between the DLP (17.10 Å} 1.77 µm) and gypsum groups. Regarding precision, the RMSE ranking was gypsum = DLP = SLA < PJP group. The RMSE ranges in the gypsum, DLP, PJP, and SLA groups at different times were 6.79 to 8.86 µm, 5.44 to 10.17 µm, 10.16 to 11.28 µm, and 10.94 to 32.74 µm, respectively. CONCLUSION: Although gypsum and printed preparation dies showed statistically significant differences in surface characteristics, accuracy, and dimensional stability, all tooth preparation dies were clinically tolerated and used to produce fixed restorations.
RESUMO
Background: Removable partial denture (RPD) design is crucial to long-term success in dental treatment, but shortcomings in RPD design training and competency acquisition among dental students have persisted for decades. Digital production is increasing in prevalence in stomatology, and a digital RPD (D-RPD) module, under the framework of the certified Objective Manipulative Skill Examination of Dental Technicians (OMEDT) system reported in our previous work, may improve on existing RPD training models for students. Objective: We aimed to determine the efficacy of a virtual 3D simulation-based progressive digital training module for RPD design compared to traditional training. Methods: We developed a prospective cohort study including dental technology students at the Stomatology College of Chongqing Medical University. Cohort 1 received traditional RPD design training (7 wk). Cohort 2 received D-RPD module training based on text and 2D sketches (7 wk). Cohort 3 received D-RPD module pilot training based on text and 2D sketches (4 wk) and continued to receive training based on 3D virtual casts of real patients (3 wk). RPD design tests based on virtual casts were conducted at 1 month and 1 year after training. We collected RPD design scores and the time spent to perform each assessment. Results: We collected the RPD design scores and the time spent to perform each assessment at 1 month and 1 year after training. The study recruited 109 students, including 58 (53.2%) female and 51 male (56.8%) students. Cohort 1 scored the lowest and cohort 3 scored the highest in both tests (cohorts 1-3 at 1 mo: mean score 65.8, SD 21.5; mean score 81.9, SD 6.88; and mean score 85.3, SD 8.55, respectively; P<.001; cohorts 1-3 at 1 y: mean score 60.3, SD 16.7; mean score 75.5, SD 3.90; and mean score 90.9, SD 4.3, respectively; P<.001). The difference between cohorts in the time spent was not statistically significant at 1 month (cohorts 1-3: mean 2407.8, SD 1370.3 s; mean 1835.0, SD 1329.2 s; and mean 1790.3, SD 1195.5 s, respectively; P=.06) but was statistically significant at 1 year (cohorts 1-3: mean 2049.16, SD 1099.0 s; mean 1857.33, SD 587.39 s; and mean 2524.3, SD 566.37 s, respectively; P<.001). Intracohort comparisons indicated that the differences in scores at 1 month and 1 year were not statistically significant for cohort 1 (95% CI -2.1 to 13.0; P=.16), while cohort 3 obtained significantly higher scores 1 year later (95% CI 2.5-8.7; P=.001), and cohort 2 obtained significantly lower scores 1 year later (95% CI -8.8 to -3.9; P<.001). Conclusions: Cohort 3 obtained the highest score at both time points with retention of competency at 1 year, indicating that progressive D-RPD training including virtual 3D simulation facilitated improved competency in RPD design. The adoption of D-RPD training may benefit learning outcomes.
RESUMO
Dental anatomy education for dental technology students should be developed in alignment with digital dental laboratory practices. We hypothesized that a virtually assisted sketching-based dental anatomy teaching module could improve students' acquisition of skills essential for digital restoration design. The second-year dental technology curriculum included a novel virtual technology-assisted sketching-based module for dental anatomy education. Pre- and post-course assessments evaluated students' skill sets and knowledge bases. Computer-aided design (CAD) scores were analyzed after one year to assess how the skills students developed through this module impacted their subsequent CAD performance. Participants who undertook the dental sketching-based teaching module demonstrated significantly improved theoretical knowledge of dental anatomy, dental aesthetic perception, and spatial reasoning skills. A partial least squares structural equation model indicated that the positive effects of this module on subsequent CAD performance were indirectly mediated by dental aesthetic perception, spatial reasoning, and practice time. A virtually assisted sketching-based dental anatomy teaching module significantly improved students' acquisition of skills and knowledge and positively mediated dental technology students' CAD performance.
Assuntos
Anatomia , Desenho Assistido por Computador , Instrução por Computador , Currículo , Educação em Odontologia , Avaliação Educacional , Humanos , Educação em Odontologia/métodos , Feminino , Anatomia/educação , Masculino , Avaliação Educacional/estatística & dados numéricos , Instrução por Computador/métodos , Estudantes de Odontologia , Aprendizagem , Adulto Jovem , Prótese Dentária , Planejamento de Prótese Dentária , Restauração Dentária Permanente/métodos , AdultoRESUMO
PURPOSE: To evaluate the impact of five different tooth preparation designs on the marginal and internal fit discrepancies of cobalt-chromium (CoCr) crowns produced by computer-aided designing (CAD) and selective laser melting (SLM) processes. MATERIALS AND METHODS: Five preparation data were constructed, after which design crowns were obtained. Actual crowns were fabricated using an SLM process. After the data of actual crowns were obtained with structural light scanning, intaglio surfaces of the design crown and actual crown were virtually superimposed on the preparation. The fit-discrepancies were displayed with colors, while the root means square was calculated and analyzed with one-way analysis of variance (ANOVA), Tukey's test or Kruskal-Wallis test (α =.05). RESULTS: The marginal or internal color-coded images in the five design groups were not identical. The shoulder-lip and sharp line angle groups in the CAD or SLM process had larger marginal or internal fit discrepancies compared to other groups (P < .05). In the CAD process, the mean marginal and internal fit discrepancies were 10.0 to 24.2 µm and 29.6 to 31.4 µm, respectively. After the CAD and SLM processes, the mean marginal and internal fit discrepancies were 18.4 to 40.9 µm and 39.1 to 47.1 µm, respectively. The SLM process itself resulted in a positive increase of the marginal (6.0 - 16.7 µm) and internal (9.0 - 15.7 µm) fit discrepancies. CONCLUSION: The CAD and SLM processes affected the fit of CoCr crowns and varied based on the preparation designs. Typically, the shoulder-lip and sharp line angle designs had a more significant effect on crown fit. However, the differences between the design groups were relatively small, especially when compared to fit discrepancies observed clinically.