Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Am Heart J ; 202: 49-53, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29807307

RESUMO

BACKGROUND: The Combo stent (OrbusNeich, Hoevelaken, the Netherlands) combining an abluminal, bioabsorbable polymer eluting sirolimus with a luminal CD34+ antibody to capture endothelial progenitor cells has been developed to further improve safety and efficacy of coronary interventions. We have designed a large-scale registry-based randomized clinical trial to compare the Combo stent to the Orsiro stent (Biotronik, Bülach, Switzerland) in patients undergoing percutaneous coronary intervention. METHODS: The SORT OUT X study will randomly assign 3,140 patients to treatment with Combo or Orsiro stents at 3 sites in Western Denmark. Patients are eligible if they are ≥18 years old, have chronic stable coronary artery disease or acute coronary syndromes, and have ≥1 coronary lesion with >50% diameter stenosis requiring treatment with a drug-eluting stent. The primary end point target lesion failure is a composite of cardiac death, myocardial infarction (not related to other than index lesion), or target lesion revascularization within 12 months. Clinically driven event detection will be derived from validated Danish registries. An event rate of 4.2% is assumed in each stent group. With a sample size of 1,570 patients in each treatment arm, a 2-group large-sample normal approximation test of proportions with a 1-sided 5% significance level will have 90% power to detect noninferiority of the Combo stent compared with the Orsiro stent with a predetermined noninferiority margin of 2.1%. CONCLUSION: The SORT OUT X trial will determine whether the dual-therapy Combo stent is noninferior to the Orsiro stent with respect to clinically driven events (ClinicalTrials.govNCT03216733).


Assuntos
Síndrome Coronariana Aguda/terapia , Antígenos CD34/imunologia , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea , Sirolimo/administração & dosagem , Adulto , Anticorpos , Materiais Revestidos Biocompatíveis , Feminino , Humanos , Masculino , Desenho de Prótese , Sistema de Registros , Projetos de Pesquisa , Método Simples-Cego
2.
Lancet ; 385(9977): 1527-35, 2015 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-25601789

RESUMO

BACKGROUND: New-generation drug-eluting coronary stents have reduced the risk of coronary events, especially in patients with complex disease or lesions. To what extent different stent platforms, polymers, and antiproliferative drugs affect outcomes, however, is unclear. We investigated the safety and efficacy of a third-generation stent by comparing a highly biocompatible durable-polymer-coated zotarolimus-eluting stent with a biodegradable-polymer-coated biolimus-eluting stent. METHODS: This open-label, randomised, multicentre, non-inferiority trial was done at three sites across western Denmark. All patients who presented with stable coronary artery disease or acute coronary syndromes and at least one coronary artery lesion (more than 50% stenosis) from March, 2011, to August, 2012, were assessed for eligibility. Patients were randomly assigned in a 1:1 ratio to receive either the durable-polymer zotarolimus-eluting stent or the biodegradable-polymer biolimus-eluting stent. The primary endpoint was a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion) and efficacy (target-lesion revascularisation) at 12 months, analysed by intention to treat. The trial was powered to assess non-inferiority of durable-polymer zotarolimus-eluting stent compared with the biodegradable-polymer biolimus-eluting stent with a predetermined non-inferiority margin of 0·025. This trial is registered with ClinicalTrials.gov, number NCT01956448. FINDINGS: Of 7103 screened, 1502 patients with 1883 lesions were assigned to receive the durable-polymer zotarolimus-eluting stent and 1497 patients with 1791 lesions to receive the biodegradable-polymer biolimus-eluting stent. 79 (5·3%) and 75 (5·0%) patients, respectively, met the primary endpoint (absolute risk difference 0·0025, upper limit of one-sided 95% CI 0·016%; p=0·004). The individual components of the primary endpoint did not differ significantly between stent types at 12 months. INTERPRETATION: The durable-polymer-coated zotarolimus-eluting stent was non-inferior to the biodegradable-polymer-coated biolimus-eluting stent in unselected patients. FUNDING: Medtronic Cardiovascular and Biosensors Interventional Technologies.


Assuntos
Stents Farmacológicos , Imunossupressores/administração & dosagem , Isquemia Miocárdica/terapia , Intervenção Coronária Percutânea , Sirolimo/análogos & derivados , Implantes Absorvíveis , Idoso , Materiais Revestidos Biocompatíveis , Dinamarca , Desenho de Equipamento , Feminino , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/etiologia , Isquemia Miocárdica/mortalidade , Polímeros , Sirolimo/administração & dosagem , Resultado do Tratamento
3.
Lancet ; 381(9867): 661-9, 2013 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-23374649

RESUMO

BACKGROUND: Third-generation biodegradable polymer drug-eluting stents might reduce the risk of stent thrombosis compared with first-generation permanent polymer drug-eluting stents. We aimed to further investigate the effects of a biodegradable polymer biolimus-eluting stent compared with a durable polymer-coated sirolimus-eluting stent in a population-based setting. METHODS: This randomised, multicentre, all-comer, non-inferiority trial was undertaken at three sites across western Denmark. Eligible patients were aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes, and at least one coronary artery lesion (>50% diameter stenosis). We randomly assigned patients (1:1) using an independently managed computer-generated allocation sequence to receive either a biolimus-eluting biodegradable polymer stent (Nobori, Terumo, Tokyo, Japan) or a sirolimus-eluting permanent polymer stent (Cypher Select Plus, Cordis, Johnson & Johnson, Warren, NJ, USA). The primary endpoint was a composite of safety (cardiac death, myocardial infarction, definite stent thrombosis) and efficacy (target vessel revascularisation) at 9 months, analysed by intention to treat (non-inferiority margin of 0·02). This trial is registered with ClinicalTrials.gov, number NCT01254981. FINDINGS: From July, 2009, to January, 2011, we assigned 1229 patients (1532 lesions) to receive the biolimus-eluting stent and 1239 (1555 lesions) to receive the sirolimus-eluting stent. One patient was lost to follow-up because of emigration. Intention-to-treat analysis showed that 50 (4·1%) patients who were assigned the biolimus-eluting stent and 39 (3·1%) who were assigned the sirolimus-eluting stent met the primary endpoint (risk difference 0·9% [upper limit of one-sided 95% CI 2·1%]; p(non-inferiority)=0·06). Significantly more patients in the biolimus-eluting stent group had definite stent thrombosis at 12 months than did those in the sirolimus-eluting stent group (9 [0·7%] vs 2 [0·2%], risk difference 0·6% [95% CI 0·0-1·1]; p=0·034). Per-protocol analysis showed that 45 (3·8%) of 1193 patients who received a biolimus-eluting stent and 39 (3·2%) of 1208 who received a sirolimus-eluting stent met the primary endpoint (risk difference 0·5% [upper limit of one-sided 95% CI 1·8%]; p(non-inferiority)=0·03). INTERPRETATION: At 1 year follow-up, the biodegradable polymer biolimus-eluting Nobori stent did not improve clinical results compared with a first-generation sirolimus-eluting stent. We will need to obtain long-term data before we can make recommendations for the role of this biolimus-eluting stent in routine clinical practice. FUNDING: Terumo and Cordis (Johnson & Johnson).


Assuntos
Implantes Absorvíveis , Síndrome Coronariana Aguda/terapia , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Sirolimo/análogos & derivados , Sirolimo/uso terapêutico , Síndrome Coronariana Aguda/mortalidade , Idoso , Aspirina/uso terapêutico , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/epidemiologia , Trombose Coronária/etiologia , Stents Farmacológicos/efeitos adversos , Feminino , Humanos , Masculino , Infarto do Miocárdio/epidemiologia , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/uso terapêutico , Polímeros , Retratamento/estatística & dados numéricos
4.
Nano Lett ; 12(4): 2060-6, 2012 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-22409386

RESUMO

As of yet, III-V p-type field-effect transistors (p-FETs) on Si have not been reported, due partly to materials and processing challenges, presenting an important bottleneck in the development of complementary III-V electronics. Here, we report the first high-mobility III-V p-FET on Si, enabled by the epitaxial layer transfer of InGaSb heterostructures with nanoscale thicknesses. Importantly, the use of ultrathin (thickness, ~2.5 nm) InAs cladding layers results in drastic performance enhancements arising from (i) surface passivation of the InGaSb channel, (ii) mobility enhancement due to the confinement of holes in InGaSb, and (iii) low-resistance, dopant-free contacts due to the type III band alignment of the heterojunction. The fabricated p-FETs display a peak effective mobility of ~820 cm(2)/(V s) for holes with a subthreshold swing of ~130 mV/decade. The results present an important advance in the field of III-V electronics.


Assuntos
Antimônio/química , Gálio/química , Índio/química , Membranas Artificiais , Nanoestruturas/química , Silício/química , Transistores Eletrônicos , Tamanho da Partícula , Porosidade , Propriedades de Superfície
5.
Nanotechnology ; 23(41): 415102, 2012 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-23010859

RESUMO

The perspectives offered by vertical arrays of nanowires for biosensing applications in living cells depend on the access of individual nanowires to the cell interior. Recent results on electrical access and molecular delivery suggest that direct access is not always obtained. Here, we present a generic approach to directly visualize the membrane conformation of living cells interfaced with nanowire arrays, with single nanowire resolution. The method combines confocal z-stack imaging with an optimized cell membrane labelling strategy which was applied to HEK293 cells interfaced with 2-11 µm long and 3-7 µm spaced nanowires with various surface coatings (bare, aminosilane-coated or polyethyleneimine-coated indium arsenide). We demonstrate that, for all commonly used nanowire lengths, spacings and surface coatings, nanowires generally remain enclosed in a membrane compartment, and are thereby not in direct contact with the cell interior.


Assuntos
Membrana Celular/ultraestrutura , Nanofios/análise , Imagem Óptica/métodos , Arsenicais/química , Células HEK293 , Humanos , Índio/química , Microscopia Confocal , Polietilenoimina/química , Silanos/química , Análise Serial de Tecidos
6.
Nano Lett ; 11(11): 5008-12, 2011 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-22007924

RESUMO

Nanoscale size effects drastically alter the fundamental properties of semiconductors. Here, we investigate the dominant role of quantum confinement in the field-effect device properties of free-standing InAs nanomembranes with varied thicknesses of 5-50 nm. First, optical absorption studies are performed by transferring InAs "quantum membranes" (QMs) onto transparent substrates, from which the quantized sub-bands are directly visualized. These sub-bands determine the contact resistance of the system with the experimental values consistent with the expected number of quantum transport modes available for a given thickness. Finally, the effective electron mobility of InAs QMs is shown to exhibit anomalous field and thickness dependences that are in distinct contrast to the conventional MOSFET models, arising from the strong quantum confinement of carriers. The results provide an important advance toward establishing the fundamental device physics of two-dimensional semiconductors.


Assuntos
Arsenicais/química , Índio/química , Membranas Artificiais , Nanoestruturas/química , Nanoestruturas/ultraestrutura , Transporte de Elétrons , Teste de Materiais , Tamanho da Partícula
7.
Eur Heart J Cardiovasc Imaging ; 19(3): 329-338, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28369332

RESUMO

Aims: To show non-inferiority of the 67- or 87 µm thick, sirolimus-eluting Orsiro drug eluting stent (DES) to the 122 µm thick, biolimus-eluting Nobori DES regarding size of vessel lumen outside the stent at 13-month follow-up. Methods and results: This study was a substudy to the SORT-OUT VII trial, a prospective, 1:1-randomized, comparison of the two stents in patients with stable coronary artery disease or acute coronary syndrome. Optical coherence tomography was acquired after percutaneous coronary intervention and at 13-month follow-up. The substudy was powered to access non-inferiority (Δ = 0.60 mm2) of the Orsiro DES to the Nobori DES for the primary endpoint of mean extra stent lumen (ESL) i.e. vessel lumen outside the stent at 13-month follow-up. We randomized 124 patients to Orsiro (n = 60) or Nobori (n = 64). Due to a difference in the one-sided 95%-confidence interval of 0.26 mm2, but increased to 0.82 mm2 after appropriate log-transformation, it could not be rejected that Orsiro exceeded the non-inferiority limit. Testing for superiority, Orsiro had a significantly larger mean ESL at follow-up (Orsiro: 0.11 mm2 [0.02;0.30] mm2, Nobori: 0.03 mm2 [0.00;0.17] mm2, P = 0.04). Stent strut coverage was, Orsiro: 97.6 % [93.8;99.4]%, and Nobori: 96.3 % [90.5;98,6]% (P = 0.13). Conclusion: Orsiro DES had a significantly larger mean ESL at follow-up and it could not be excluded that Orsiro exceeded the limit for non-inferiority. Nobori DES had a more heterogeneous distribution of neointima but stent strut coverage did not differ significantly between the two stents.


Assuntos
Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Stents Farmacológicos , Sirolimo/análogos & derivados , Sirolimo/farmacologia , Tomografia de Coerência Óptica/métodos , Implantes Absorvíveis , Angioplastia Coronária com Balão/métodos , Feminino , Seguimentos , Humanos , Masculino , Neointima/diagnóstico por imagem , Neointima/patologia , Distribuição Normal , Polímeros , Estudos Prospectivos , Desenho de Prótese , Valores de Referência , Medição de Risco , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular/fisiologia
8.
EuroIntervention ; 13(11): 1336-1344, 2017 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-28846543

RESUMO

AIMS: Our aim was to report the long-term safety and efficacy of the biodegradable polymer-coated biolimus- eluting Nobori stent compared to the durable polymer-coated sirolimus-eluting CYPHER stent. METHODS AND RESULTS: SORT OUT V randomised 2,468 patients 1:1 to the Nobori (n=1,229) versus the CYPHER stent (n=1,239). Clinically driven event detection based on Danish registries was used. The primary endpoint was a composite of safety (cardiac death, myocardial infarction, definite stent thrombosis) and efficacy (target vessel revascularisation). Individual components of the primary endpoint comprise the secondary endpoints. At five-year follow-up, the composite endpoint rate was found to be similar in patients treated with the two study stents (Nobori 182/1,229 [14.8%] vs. CYPHER 197/1,239 [15.8%]; odds ratio [OR] 0.93, 95% CI: 0.75-1.16; p=0.53). The rates of definite stent thrombosis were also found to be similar in patients treated with the two study stents (Nobori 23/1,229 [1.9%] vs. CYPHER 18/1,239 [1.5%]; OR 1.31, 95% CI: 0.70-2.47; p=0.40), as were the other secondary endpoints. CONCLUSIONS: At five-year follow-up, the Nobori stent with a biodegradable polymer coating provided a similar safety and efficacy profile when compared to the durable polymer first-generation CYPHER stent.


Assuntos
Implantes Absorvíveis , Síndrome Coronariana Aguda/terapia , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros , Sirolimo/análogos & derivados , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/mortalidade , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Trombose Coronária/mortalidade , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Razão de Chances , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Recidiva , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
9.
JACC Cardiovasc Interv ; 10(3): 255-264, 2017 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-28109874

RESUMO

OBJECTIVES: The authors sought to compare the safety and efficacy of the biocompatible durable-polymer zotarolimus-eluting stent with the biodegradable-polymer biolimus-eluting stent in unselected coronary patients. BACKGROUND: Biodegradable-polymer biolimus-eluting stents are superior to first-generation durable-polymer drug-eluting stents in long-term randomized all-comer trials. Long-term data comparing them to second-generation durable-polymer drug-eluting stents are lacking. METHODS: The study was a randomized, multicenter, all-comer, noninferiority trial in patients with chronic stable coronary artery disease or acute coronary syndromes and at least 1 coronary artery lesion requiring treatment with a drug-eluting stent. Endpoints included major adverse cardiac events (MACE), a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion) and efficacy (target lesion revascularization); the individual endpoints of MACE; all-cause mortality; any myocardial infarction; target vessel revascularization; and definite or probable stent thrombosis at 36 months. RESULTS: From March 2011 to August 2012, 2,999 patients were randomly assigned (1:1) to receive either the zotarolimus-eluting (1,502 patients) or the biolimus-eluting (1,497 patients) stent. At 3-year follow-up, MACE occurred in 128 (8.6%) patients assigned to the durable-polymer zotarolimus-eluting stent and in 144 (9.6%) assigned to the biodegradable-polymer biolimus-eluting stent (p = 0.36). Occurrence of cardiac death (2.7% vs. 3.4%), myocardial infarction not clearly attributable to a non-target lesion (2.7% vs. 2.5%), and target lesion revascularization (5.4% vs. 5.5%) did not differ significantly between the 2 groups. Definite very late stent thrombosis occurred in 6 (0.4%) patients assigned to the durable-polymer zotarolimus-eluting stent and in 10 (0.7%) assigned to the biodegradable-polymer biolimus-eluting stent (p = 0.33). CONCLUSIONS: At 3-year follow-up, the durable-polymer zotarolimus-eluting stent and the biodegradable-polymer biolimus-eluting stent were similar in clinical outcome, with no significant difference in safety and efficacy outcomes, including stent thrombosis.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Sirolimo/análogos & derivados , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Dinamarca , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Modelos de Riscos Proporcionais , Desenho de Prótese , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
10.
Artigo em Inglês | MEDLINE | ID: mdl-27412869

RESUMO

BACKGROUND: Coronary drug-eluting stents with biodegradable polymers have been designed to improve safety and efficacy. METHODS AND RESULTS: The Scandinavian Organization for Randomized Trials With Clinical Outcome (SORT OUT) VII trial-a large-scale registry-based randomized, multicenter, single-blind, 2-arm, noninferiority trial-compared 2 biodegradable polymer drug-eluting stents: the thin-strut cobalt-chromium sirolimus-eluting Orsiro stent and the stainless steel biolimus-eluting Nobori stent in an all-comer patient population. The primary end point target lesion failure was a composite of cardiac death, myocardial infarction (not related to other than index lesion), or target lesion revascularization within 1 year, analyzed by intention to treat (noninferiority margin of 3.0%). Clinically driven event detection based on Danish registries was used. A total of 1261 patients were assigned to receive the sirolimus-eluting stent (1590 lesions) and 1264 patients to the biolimus-eluting stent (1588 lesions). At 1 year, the composite end point target lesion failure occurred in 48 patients (3.8%) in the sirolimus-eluting group and in 58 patients (4.6%) in the biolimus-eluting group (absolute risk difference, -0.78% [upper limit of 1-sided 95% confidence interval, 0.61%]; P<0.0001). Rates of definite stent thrombosis occurred in 5 (0.4%) of the sirolimus-eluting group compared with 15 (1.2%) biolimus-eluting stent-treated patients (rate ratio, 0.33; 95% confidence interval, 0.12-0.92; P=0.034), which largely was attributable to a lower risk of subacute definite stent thrombosis: 0.1% versus 0.6% (rate ratio, 0.12; 95% confidence interval, 0.02-1.00; P=0.05). CONCLUSIONS: The thin-strut sirolimus-eluting Orsiro stent was noninferior to the biolimus-eluting Nobori stent in unselected patients for target lesion failure at 1 year. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01879358.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Sirolimo/análogos & derivados , Idoso , Fármacos Cardiovasculares/efeitos adversos , Ligas de Cromo , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Países Escandinavos e Nórdicos , Método Simples-Cego , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Aço Inoxidável , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA