Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Clin Infect Dis ; 72(1): 50-60, 2021 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-31900486

RESUMO

BACKGROUND: The Pox-Protein Public-Private Partnership is performing a suite of trials to evaluate the bivalent subtype C envelope protein (TV1.C and 1086.C glycoprotein 120) vaccine in the context of different adjuvants and priming agents for human immunodeficiency virus (HIV) type 1 (HIV-1) prevention. METHODS: In the HIV Vaccine Trials Network 111 trial, we compared the safety and immunogenicity of DNA prime followed by DNA/protein boost with DNA/protein coadministration injected intramuscularly via either needle/syringe or a needle-free injection device (Biojector). One hundred thirty-two healthy, HIV-1-uninfected adults were enrolled from Zambia, South Africa, and Tanzania and were randomized to 1 of 6 arms: DNA prime, protein boost by needle/syringe; DNA and protein coadministration by needle/syringe; placebo by needle/syringe; DNA prime, protein boost with DNA given by Biojector; DNA and protein coadministration with DNA given by Biojector; and placebo by Biojector. RESULTS: All vaccinations were safe and well tolerated. DNA and protein coadministration was associated with increased HIV-1 V1/V2 antibody response rate, a known correlate of decreased HIV-1 infection risk. DNA administration by Biojector elicited significantly higher CD4+ T-cell response rates to HIV envelope protein than administration by needle/syringe in the prime/boost regimen (85.7% vs 55.6%; P = .02), but not in the coadministration regimen (43.3% vs 48.3%; P = .61). CONCLUSIONS: Both the prime/boost and coadministration regimens are safe and may be promising for advancement into efficacy trials depending on whether cellular or humoral responses are desired. CLINICAL TRIALS REGISTRATION: South African National Clinical Trials Registry (application 3947; Department of Health [DoH] no. DOH-27-0715-4917) and ClinicalTrials.gov (NCT02997969).


Assuntos
Vacinas contra a AIDS , Infecções por HIV , HIV-1 , Vacinas contra a AIDS/uso terapêutico , Adulto , DNA , Anticorpos Anti-HIV , Infecções por HIV/prevenção & controle , HIV-1/genética , Humanos , Imunização Secundária , Imunogenicidade da Vacina , Polissorbatos , África do Sul , Esqualeno , Tanzânia , Zâmbia
2.
Phys Med Biol ; 69(6)2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38330494

RESUMO

Modern radiotherapy delivers highly conformal dose distributions to irregularly shaped target volumes while sparing the surrounding normal tissue. Due to the complex planning and delivery techniques, dose verification and validation of the whole treatment workflow by end-to-end tests became much more important and polymer gel dosimeters are one of the few possibilities to capture the delivered dose distribution in 3D. The basic principles and formulations of gel dosimetry and its evaluation methods are described and the available studies validating device-specific geometrical parameters as well as the dose delivery by advanced radiotherapy techniques, such as 3D-CRT/IMRT and stereotactic radiosurgery treatments, the treatment of moving targets, online-adaptive magnetic resonance-guided radiotherapy as well as proton and ion beam treatments, are reviewed. The present status and limitations as well as future challenges of polymer gel dosimetry for the validation of complex radiotherapy techniques are discussed.


Assuntos
Polímeros , Radioterapia Conformacional , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos , Radiometria/métodos
3.
J Acquir Immune Defic Syndr ; 96(4): 350-360, 2024 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-38916429

RESUMO

BACKGROUND: An effective vaccine is required to end the HIV pandemic. We evaluated the safety and immunogenicity of a DNA (DNA-HIV-PT123) vaccine with low- or high-dose bivalent (TV1.C and 1086.C glycoprotein 120) subtype C envelope protein combinations, adjuvanted with MF59 or AS01B. METHODS: HIV Vaccine Trials Network (HVTN)108 was a randomized, placebo-controlled, double-blind, phase 1/2a trial conducted in the United States and South Africa. HIV-negative adults were randomly assigned to 1 of 7 intervention arms or placebo to assess DNA prime with DNA/protein/adjuvant boosts, DNA/protein/adjuvant co-administration, and low-dose protein/adjuvant regimens. HVTN111 trial participants who received an identical regimen were also included. Outcomes included safety and immunogenicity 2 weeks and 6 months after final vaccination. RESULTS: From June 2016 to July 2018, 400 participants were enrolled (N = 334 HVTN108, N = 66 HVTN111); 370 received vaccine and 30 received placebo. There were 48 grade 3 and 3 grade 4 reactogenicity events among 39/400 (9.8%) participants, and 32 mild/moderate-related adverse events in 23/400 (5.8%) participants. All intervention groups demonstrated high IgG response rates (>89%) and high magnitudes to HIV-1 Env gp120 and gp140 proteins; response rates for AS01B-adjuvanted groups approached 100%. V1V2 IgG magnitude, Fc-mediated functions, IgG3 Env response rates, and CD4+ T-cell response magnitudes and rates were higher in the AS01B-adjuvanted groups. The AS01B-adjuvanted low-dose protein elicited greater IgG responses than the higher protein dose. CONCLUSIONS: The vaccine regimens were generally well tolerated. Co-administration of DNA with AS01B-adjuvanted bivalent Env gp120 elicited the strongest humoral responses; AS01B-adjuvanted regimens elicited stronger CD4+ T-cell responses, justifying further evaluation.ClinicalTrials.gov registration: NCT02915016, registered 26 September 2016.


Assuntos
Vacinas contra a AIDS , Adjuvantes Imunológicos , Anticorpos Anti-HIV , Proteína gp120 do Envelope de HIV , Infecções por HIV , HIV-1 , Polissorbatos , Esqualeno , Vacinas de DNA , Humanos , Vacinas contra a AIDS/imunologia , Vacinas contra a AIDS/administração & dosagem , Vacinas contra a AIDS/efeitos adversos , Vacinas de DNA/imunologia , Vacinas de DNA/administração & dosagem , Vacinas de DNA/efeitos adversos , Feminino , Masculino , Adulto , Esqualeno/administração & dosagem , Polissorbatos/administração & dosagem , Proteína gp120 do Envelope de HIV/imunologia , Adjuvantes Imunológicos/administração & dosagem , HIV-1/imunologia , Infecções por HIV/imunologia , Infecções por HIV/prevenção & controle , Anticorpos Anti-HIV/sangue , Método Duplo-Cego , Pessoa de Meia-Idade , Adulto Jovem , Adjuvantes de Vacinas/administração & dosagem , África do Sul , Imunogenicidade da Vacina , Adolescente , Estados Unidos
4.
Med Phys ; 48(9): 5501-5510, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34260079

RESUMO

OBJECTIVE: To assess the feasibility of performing dose measurements in the target (prostate) and an adjacent organ at risk (rectum) using polymer dosimetry gel and thermoluminescence detectors (TLDs) in an anthropomorphic, deformable, and multimodal pelvis phantom (ADAM PETer). METHODS: The 3D printed prostate organ surrogate of the ADAM PETer phantom was filled with polymer dosimetry gel. Nine TLD600 (LiF:Mg,Ti) were installed in 3 × 3 rows on a specifically designed 3D-printed TLD holder. The TLD holder was inserted into the rectum at the level of the prostate and fixed by a partially inflated endorectal balloon. Computed tomography (CT) images were taken and treatment planning was performed. A prescribed dose of 4.5 Gy was delivered to the planning target volume (PTV). The doses measured by the dosimetry gel in the prostate and the TLDs in the rectum ("measured dose") were compared to the doses calculated by the treatment planning system ("planned dose") on a voxel-by-voxel basis. RESULTS: In the prostate organ surrogate, the 3D-γ-index was 97.7% for the 3% dose difference and 3 mm distance to agreement criterium. In the center of the prostate organ surrogate, measured and planned doses showed only minor deviations (<0.1 Gy, corresponding to a percentage error of 2.22%). On the edges of the prostate, slight differences between planned and measured doses were detected with a maximum deviation of 0.24 Gy, corresponding to 5.3% of the prescribed dose. The difference between planned and measured doses in the TLDs was on average 0.08 Gy (range: 0.02-0.21 Gy), corresponding to 1.78% of the prescribed dose (range: 0.44%-4.67%). CONCLUSIONS: The present study demonstrates the feasibility of using polymer dosimetry gel and TLDs for 3D and 1D dose measurements in the prostate and the rectum organ surrogates in an anthropomorphic, deformable and multimodal phantom. The described methodology might offer new perspectives for end-to-end tests in image-guided adaptive radiotherapy workflows.


Assuntos
Polímeros , Radiometria , Estudos de Viabilidade , Humanos , Masculino , Pelve/diagnóstico por imagem , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Dosimetria Termoluminescente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA