OBJECTIVE: To evaluate the clinical outcomes of pediatric patients implanted a novel 4.5âmm wide laser ablated titanium bone anchored implant system and to evaluate the implant stability over the first 12-month period. STUDY DESIGN: A prospective, single-subject, repeated measure, cohort study. Participants served as their own controls. SETTING: Community and tertiary referral hospital pediatric assessment center. PATIENTS: A total of 115 consecutive pediatric patients aged 4 to 15âyears were implanted with 176 laser ablated titanium bone anchored implants from January 2016 to January 2019. MAIN OUTCOME MEASURE: Clinical outcomes, implant failure rates, and post implantation implant stability quotient (ISQ) scores were studied over the first 12-month period. Data were analyzed for statistical significance through mixed effect modeling, with the significance level pâ=â0.01. RESULTS: A median 12-month survival of 96.6% was observed. Six implants (3.5%) were lost in total, one of these (0.6%) was lost due to trauma. Adverse skin reactions (Holgers grade 2-4) were observed in 4.4% of all postoperative visits, occurring in 22 individuals (19.1%). Neither the ISQ high (ISQH) nor ISQ low (ISQL) values increased significantly between the stage 1 and 2 surgeries. In contrast, the ISQ results, irrespective of abutment size, demonstrated an increasing trend from 49.1 to 57 over the 12âmonths review period. A statistically significant change was only demonstrated from the 3âmonths follow up onwards. CONCLUSION: The use of 4.5âmm wide laser-ablated titanium bone anchored hearing implants resulted in superior survival rates and excellent clinical outcomes compared with previous implant systems.
Assuntos
Auxiliares de Audição , Perda Auditiva , Criança , Estudos de Coortes , Audição , Auxiliares de Audição/efeitos adversos , Perda Auditiva/etiologia , Perda Auditiva/cirurgia , Humanos , Lasers , Osseointegração , Estudos Prospectivos , Análise de Frequência de Ressonância , Âncoras de Sutura , TitânioRESUMO
OBJECTIVES: To evaluate complication rates and resonance frequency analysis (RFA) of the stability of a new laser-ablated titanium Bone Anchored hearing Implant system in children with Down syndrome. METHODS: A prospective, single-subject, repeat measure, cohort study in which each participant served as their own control. Consecutive paediatric patients 4yrs- 15 years old, with a primary diagnosis of Down syndrome (trisomy 21) were implanted between January 2015-January 2020 with BHX Oticon wide implants. Evaluation of soft tissue reactions, fixture failure rates and post implantation Implant stability Quotient (ISQ) at both fixtures and abutment levels were studied over a 12-month period. Data was analysed for statistical significance through mixed effect modelling with significance set at p = 0.01. RESULTS: 31 consecutive paediatric patients with a diagnosis of Down syndrome were implanted with 43 Ponto BHX Oticon™ implant system. Twelve children had bilateral implants and nineteen were unilateral. Over the 12 month follow up 2 fixtures (4.6%) were lost, and adverse skin reactions (Holgers >2) were recorded in 3.2% of all clinical reviews. Implant level stability quotient showed no statically significant change between first and second stage 71.1-71.7. Abutment level ISQ increased from 46.2 to 56.7 p = 0.0001 at the 12-month review point as compared to that recorded at loading. CONCLUSION: Implant survival and adverse skin reactions were found to be in keeping with those in published literature and much improved compared to previous implant systems placed at this centre. Although abutment level ISQ showed an increase over the review period no correlation between this and implant loss can be concluded.