Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Catheter Cardiovasc Interv ; 90(3): 380-386, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28109036

RESUMO

OBJECTIVES: To compare the long-term clinical outcomes of paclitaxel drug-coated-balloons (DCB) and everolimus-eluting-stents (EES) following the treatment of de novo small vessel coronary artery disease. BACKGROUND: It is currently unclear whether treatment of de novo small vessel coronary disease with DCB is comparable to second generation drug-eluting stents, which are the current standard of care. METHODS: The present study enrolled 90 patients with small vessel coronary disease from the DCB treatment arm of the BELLO (Balloon Elution and Late Loss Optimization) trial and 2,000 patients treated with EES at the San Raffaele Scientific Institute. Propensity score matching was performed to adjust for differences in baseline clinical and angiographic characteristics, yielding a total of 181 patients: 90 patients with 94 lesions receiving DCB and 91 patients with 94 lesions receiving EES. Major adverse cardiac events (MACE) were defined as the composite of cardiac death, recurrent non-fatal myocardial infarction, and target vessel revascularization. RESULTS: After propensity score matching, baseline clinical and angiographic characteristics were similar between the two groups. The cumulative MACE rate at 1-year was 12.2% with DCB and 15.4% with EES (P = 0.538). Patients in the DCB group had similar TLR rates as compared to EES over the same interval (4.4% vs. 5.6%; P = 0.720). There were no cases of definite or probable stent or vessel thrombosis. CONCLUSIONS: The use of paclitaxel-DCB appears to be associated with similar clinical outcomes when compared to second-generation-EES in small coronary artery disease. The findings of this study should be confirmed with larger prospective randomized studies with longer follow-up. © 2017 Wiley Periodicals, Inc.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Vasos Coronários , Stents Farmacológicos , Everolimo/administração & dosagem , Paclitaxel/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Distribuição de Qui-Quadrado , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Vasos Coronários/diagnóstico por imagem , Everolimo/efeitos adversos , Feminino , Humanos , Itália , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Paclitaxel/efeitos adversos , Pontuação de Propensão , Modelos de Riscos Proporcionais , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
Cardiovasc Revasc Med ; 18(1): 4-9, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28011243

RESUMO

OBJECTIVES: To evaluate the impact of diabetes on the efficacy of drug-eluting balloon (DEB) as compared to paclitaxel-eluting stent (PES) for the reduction of restenosis in small vessels according to the presence of diabetes in patients enrolled in the BELLO (Balloon Elution and Late Loss Optimization) trial. BACKGROUND: Small vessel disease is common in diabetic patients but currently there are no available data regarding DEB in these patients. METHODS: In the BELLO trial, 182 patients with lesions in small vessels were randomized 1:1 to receive DEB or PES. In the current sub analysis, patients were stratified according to the presence of diabetes. The diabetic group consisted of 74 patients (DEB=39, PES=35) and the nondiabetic group of 108 patients (DEB=51, PES=57). Angiographic endpoints examined were in-stent/in-balloon and in-segment late loss and binary restenosis at 6 months. Clinical endpoints were major adverse cardiac events (MACE; death, myocardial infarction, target vessel revascularization) at 1 year. RESULTS: In-stent/in-balloon late loss was significantly less with DEB as compared to PES in both diabetic (0.05±0.41 vs. 0.30±0.51mm, p=0.033) and nondiabetic patients (0.10±0.36 vs. 0.29±0.40mm, p=0.015). In patients with diabetes, angiographic restenosis and in-segment late loss were significantly lower with DEB as compared to PES (respectively, 6.3% vs. 25.0%; p=0.039 and -0.013±0.39 vs. 0.25±0.53; p=0.023), with no differences noted in nondiabetic patients. The cumulative MACE rate at 1 year was similar between DEB and PES in both the diabetic (13.2% vs. 25%, p=0.194) and nondiabetic groups (11.8% vs. 14.3%, p=0.699). CONCLUSIONS: Diabetes does not appear to have a negative impact on the efficacy of DEB in small vessels, which were associated with better angiographic outcomes at 6 months in this complex subgroup. Larger studies are needed to confirm these findings.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Estenose Coronária/terapia , Angiopatias Diabéticas/terapia , Stents Farmacológicos , Paclitaxel/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Angiografia Coronária , Reestenose Coronária/etiologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Angiopatias Diabéticas/diagnóstico por imagem , Angiopatias Diabéticas/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Estudos Prospectivos , Desenho de Prótese , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento
3.
J Am Coll Cardiol ; 65(8): 805-815, 2015 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-25720624

RESUMO

BACKGROUND: The use of drug-eluting stents (DES) in patients at high risk of bleeding or thrombosis has not been prospectively studied; limited data are available in patients who have a low restenosis risk. OBJECTIVES: This study sought to compare a hydrophilic polymer-based, second-generation zotarolimus-eluting stent (ZES) with a unique drug fast-release profile versus bare-metal stents (BMS) under similar durations of dual-antiplatelet therapy (DAPT). METHODS: We randomly assigned 1,606 patients with stable or unstable symptoms, and who on the basis of thrombotic bleeding or restenosis risk criteria, qualified as uncertain candidates for DES, to receive ZES or BMS. DAPT duration was on the basis of patient characteristics, rather than stent characteristics, and allowed for a personalized 1-month dual antiplatelet regimen. The primary endpoint was the risk of 1-year major adverse cardiovascular events (MACE), which included death, myocardial infarction (MI), or target vessel revascularization (TVR). RESULTS: Median DAPT duration was 32 days (interquartile range [IQR]: 30 to 180 days) and did not differ between the groups. In the ZES group, 140 patients (17.5%) reached the primary endpoint, compared with 178 patients (22.1%) in the BMS group (hazard ratio: 0.76; 95% confidence interval: 0.61 to 0.95; p = 0.011) as a result of lower MI (2.9% vs. 8.1%; p < 0.001) and TVR rates (5.9% vs.10.7%; p = 0.001) in the ZES group. Definite or probable stent thrombosis was also significantly reduced in ZES recipients (2.0% vs. 4.1%; p = 0.019). CONCLUSIONS: Compared with BMS, DES implantation using a stent with a biocompatible polymer and fast drug-eluting characteristics, combined with an abbreviated, tailored DAPT regimen, resulted in a lower risk of 1-year MACE in uncertain candidates for DES implantation. (Zotarolimus-eluting Endeavor Sprint Stent in Uncertain DES Candidates [ZEUS] Study; NCT01385319).


Assuntos
Doença da Artéria Coronariana/cirurgia , Reestenose Coronária , Stents Farmacológicos/efeitos adversos , Hemorragia , Intervenção Coronária Percutânea , Complicações Pós-Operatórias , Sirolimo/análogos & derivados , Ticlopidina/análogos & derivados , Idoso , Idoso de 80 Anos ou mais , Aspirina/administração & dosagem , Aspirina/efeitos adversos , Materiais Biocompatíveis/uso terapêutico , Clopidogrel , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Reestenose Coronária/prevenção & controle , Feminino , Hemorragia/etiologia , Hemorragia/prevenção & controle , Humanos , Imunossupressores/uso terapêutico , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Inibidores da Agregação Plaquetária/administração & dosagem , Inibidores da Agregação Plaquetária/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/prevenção & controle , Medição de Risco , Fatores de Risco , Sirolimo/uso terapêutico , Ticlopidina/administração & dosagem , Ticlopidina/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA