Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Catheter Cardiovasc Interv ; 89(7): 1259-1267, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28471091

RESUMO

IMPORTANCE: Long-term outcomes of an interwoven nitinol stent design represent the best in class for treatment of lower limb arterial obstructive disease METHODS: The subjects were enrolled in an open single arm study comparing the outcomes to an FDA mandated objective performance goal (OPG). RESULTS: About 325 patients (264 intention-to-treat and 64 roll-in subjects) were enrolled. Mean follow-up period was 887+/- 352 days. Treated lesion lengths were 7.8 cm ± 4.3 cm in the trial with chronic total occlusions comprising 24.6% (65/264) of subjects. Freedom from clinically driven target lesion revascularization (CD-TLR) at 12 months was 89%, at 24 and 36 months it was 84% and 82% respectively. The difference in the 12 month CD-TLR was 7% at 36 months. The difference of clinically driven-TLR at 36 months in those subjects who received their stents deployed nominally in length, compressed or elongated (between -10% and +10% nominal length) had an impact on the CD-TLR. At 2 and 3 years, freedom from CD-TLR in minimal compression was 86.7%, and was 90.0% for moderate compression. In those stents deployed with minimal, moderate, or severe elongation (10-20%, 20-40%, or >40%, respectively) freedom from CD-TLR of 84.1%, 87.4%, and 77.0% respectively at 12 months. At 2 and 3 years, freedom from CD-TLR for moderate elongation was 81.8% and 78.2%, and for severe elongation was 63.4% and 42.3%, respectively. Fractures were distinctly uncommon with this stent with a single facture event in the 36 month follow-up period. DISCUSSION: The interwoven nitinol design stent is a stent that achieves an excellent primary patency but further maintains the durability of the stent through 36 months. Optimal stent deployment remains critical to the performance of this stent device and requires optimal vessel preparation. © 2017 Wiley Periodicals, Inc.


Assuntos
Ligas , Materiais Biocompatíveis , Procedimentos Endovasculares/instrumentação , Extremidade Inferior/irrigação sanguínea , Doença Arterial Periférica/terapia , Stents , Idoso , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Desenho de Prótese , Falha de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
2.
J Vasc Interv Radiol ; 27(11): 1650-1656.e1, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27542591

RESUMO

PURPOSE: To evaluate the safety and efficacy of a self-expanding bare-metal nitinol stent (Astron; BIOTRONIK AG, Bülach, Switzerland) for the treatment of atherosclerotic lesions in the common and external iliac arteries. This study tested the hypothesis that the major adverse event (MAE) rate at 12 months was less than or equal to a performance goal of 15%. MATERIALS AND METHODS: In a prospective study that began in November 2011, 161 patients with symptomatic iliac lesions were treated with an Astron stent in the United States, Canada, and Austria. The primary endpoint was a composite rate of procedure- and stent-related MAEs at 12 months that included 30-day mortality, clinically indicated target lesion revascularization (TLR), and index limb amputation. RESULTS: The MAE rate at 12 months was 2.1% (3/146; [95% CI: 0.4% to 5.9%]; p < 0.001). The acute procedural success and 30-day clinical success outcomes were both 95% (153/161). The primary patency rate at 12 months was 89.8% (115/128). The comparison of baseline and 12-month Ankle Brachial Index (ABI) measurements showed a mean increase of 0.23 ± 0.19 (p < 0.001). The Walking Impairment Questionnaire (WIQ) PAD specific score, walking distance score, walking speed score and stair climbing score paired each showed a significant increase from baseline to 12 months (p<0.001). CONCLUSIONS: The Astron stent system was shown to be safe and effective in the treatment of patients with atherosclerotic disease. The observed MAE rate met the pre-specified performance goal of 15%. The stent demonstrated a high 12-month primary patency rate and showed improvement in quality of life measures.


Assuntos
Ligas , Procedimentos Endovasculares/instrumentação , Artéria Ilíaca , Claudicação Intermitente/terapia , Doença Arterial Periférica/terapia , Stents Metálicos Autoexpansíveis , Idoso , Índice Tornozelo-Braço , Áustria , Canadá , Constrição Patológica , Procedimentos Endovasculares/efeitos adversos , Teste de Esforço , Tolerância ao Exercício , Feminino , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Claudicação Intermitente/diagnóstico por imagem , Claudicação Intermitente/fisiopatologia , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Qualidade de Vida , Recuperação de Função Fisiológica , Sistema de Registros , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Grau de Desobstrução Vascular , Caminhada
3.
Catheter Cardiovasc Interv ; 73(2): 129-36, 2009 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-18924164

RESUMO

BACKGROUND: Previously, the Stenting and Angioplasty with Protection of Patients with High Risk for Endarterectomy (SAPPHIRE) randomized trial showed that carotid artery stenting (CAS) was not inferior to carotid endarterectomy (CEA) in the treatment of high-surgical risk patients. OBJECTIVE: The primary objective of the SAPPHIRE Worldwide Registry is to evaluate 30-day major adverse events (MAE) after CAS performed by physicians with varied experience and utilizing a formal training program. Data will be analyzed on the overall patient population and by high-risk inclusion criteria. METHODS: SAPPHIRE Worldwide is a multicenter, prospective, postapproval registry to evaluate CAS with distal protection in patients at high-risk for surgery using the Cordis PRECISE Nitinol Stent and ANGIOGUARD XP/RX Emboli Capture Guidewire. Participating physicians are encouraged to treat patients according to their standard of practice and consistent with current Food and Drug Administration-approved labeling. RESULTS: Enrollment began in October 2006. Data are available on the first 2,001 patients enrolled and followed to 30 days. Of these patients, the mean age was 72.2 +/- 9.75 yr; 62% were male; and 27.7% were symptomatic. Entry criteria for surgical high-risk included anatomic (n = 716), physiologic (n = 918), or both risk factors (n = 327). At 30-day follow-up, the MAE was 4.4% (death 1.1%, stroke 3.2%, MI 0.7%) for the overall population. Patients with anatomic risk had a significantly lower 30-day MAE than patients with physiologic risk (2.8% vs. 4.9%, P = 0.0306), respectively. CONCLUSIONS: While the number of physicians performing CAS continues to increase, MAE rates seen in this registry (4.4%) are well within an acceptable range, as was first seen in the SAPPHIRE randomized trial (4.8%). A significant decrease in MAE was seen in patients with anatomic risk compared with physiologic risk factors. The SAPPHIRE Worldwide Registry supports the use of CAS as an alternative to CEA in patients who are at high-risk for surgery due to anatomic risk factors.


Assuntos
Angioplastia , Doenças Cardiovasculares/prevenção & controle , Estenose das Carótidas/cirurgia , Competência Clínica , Educação Médica , Embolia/prevenção & controle , Endarterectomia das Carótidas/efeitos adversos , Stents , Idoso , Idoso de 80 Anos ou mais , Ligas , Angioplastia/efeitos adversos , Angioplastia/educação , Angioplastia/instrumentação , Angioplastia/mortalidade , Canadá , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/mortalidade , Estenose das Carótidas/mortalidade , Estenose das Carótidas/patologia , Embolia/etiologia , Embolia/mortalidade , Endarterectomia das Carótidas/mortalidade , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Seleção de Pacientes , Guias de Prática Clínica como Assunto , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
4.
Circ Cardiovasc Interv ; 11(1): e005891, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29326153

RESUMO

BACKGROUND: Randomized controlled trials have reported favorable 1-year outcomes with drug-coated balloons (DCBs) for the treatment of symptomatic peripheral arterial disease when compared with standard percutaneous transluminal angioplasty (PTA). Evidence remains limited on the durability of the treatment effect with DCBs in the longer term. METHODS AND RESULTS: IN.PACT SFA is a single-blind, randomized trial (Randomized Trial of IN.PACT Admiral Paclitaxel-Coated Percutaneous Transluminal Angioplasty [PTA] Balloon Catheter vs Standard PTA for the Treatment of Atherosclerotic Lesions in the Superficial Femoral Artery [SFA] and/or Proximal Popliteal Artery [PPA]) that enrolled 331 patients with symptomatic (Rutherford 2-4) femoropopliteal lesions up to 18 cm in length. Patients were randomized 2:1 to receive treatment with DCB or PTA. The 36-month assessments included primary patency, freedom from clinically driven target lesion revascularization, major adverse events, and functional outcomes. At 36 months, primary patency remained significantly higher among patients treated with DCB compared with PTA (69.5% versus 45.1%; log rank P<0.001). The rates of clinically driven target lesion revascularization were 15.2% and 31.1% (P=0.002) for the DCB and PTA groups, respectively. Functional outcomes were similarly improved between treatment groups even though subjects in the DCB group required significantly fewer reinterventions versus those in the PTA group (P<0.001 for target lesion revascularization, P=0.001 for target vessel revascularization). There were no device- or procedure-related deaths as adjudicated by an independent Clinical Events Committee. CONCLUSIONS: Three-year results demonstrate a durable and superior treatment effect among patients treated with DCB versus standard PTA, with significantly higher primary patency and lower clinically driven target lesion revascularization, resulting in similar functional improvements with reduced need for repeat interventions. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifiers: NCT01175850 for IN.PACT SFA phase I in the European Union and NCT01566461 for IN.PACT SFA phase II in the United States.


Assuntos
Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Artéria Femoral , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Artéria Poplítea , Dispositivos de Acesso Vascular , Idoso , Angioplastia com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Desenho de Equipamento , Europa (Continente) , Feminino , Artéria Femoral/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Grau de Desobstrução Vascular
5.
J Am Coll Cardiol ; 70(23): 2852-2862, 2017 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-29100702

RESUMO

BACKGROUND: The Absorb everolimus-eluting poly-L-lactic acid-based bioresorbable vascular scaffold (BVS) provides early drug delivery and mechanical support functions similar to metallic drug-eluting stents (DES), followed by complete bioresorption in approximately 3 years with recovery of vascular structure and function. The ABSORB III trial demonstrated noninferior rates of target lesion failure (cardiac death, target vessel myocardial infarction [TVMI], or ischemia-driven target lesion revascularization) at 1 year in 2,008 patients with coronary artery disease randomized to BVS versus cobalt-chromium everolimus-eluting stents (EES). OBJECTIVES: This study sought to assess clinical outcomes through 3 years following BVS implantation. METHODS: Clinical outcomes from the ABSORB III trial were analyzed by randomized treatment assignment cumulative through 3 years, and between 1 and 3 years. RESULTS: The primary composite endpoint of target lesion failure through 3 years occurred in 13.4% of BVS patients and 10.4% of EES patients (p = 0.06), and between 1 and 3 years in 7.0% versus 6.0% of patients, respectively (p = 0.39). TVMI through 3 years was increased with BVS (8.6% vs. 5.9%; p = 0.03), as was device thrombosis (2.3% vs. 0.7%; p = 0.01). In BVS-assigned patients, treatment of very small vessels (those with quantitatively determined reference vessel diameter <2.25 mm) was an independent predictor of 3-year TLF and scaffold thrombosis. CONCLUSIONS: In the ABSORB III trial, 3-year adverse event rates were higher with BVS than EES, particularly TVMI and device thrombosis. Longer-term clinical follow-up is required to determine whether bioresorption of the polymeric scaffold will influence patient prognosis. (ABSORB III Randomized Controlled Trial [RCT] [ABSORB-III]; NCT01751906).


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Imunossupressores/administração & dosagem , Intervenção Coronária Percutânea , Alicerces Teciduais , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Poliésteres , Desenho de Prótese , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento
6.
Circ Cardiovasc Interv ; 8(5)2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25969545

RESUMO

BACKGROUND: Stent-based therapy in the superficial femoral and popliteal arteries in patients with peripheral artery disease is compromised by restenosis and risk of stent fracture or distortion. A novel self-expanding nitinol stent was developed that incorporates an interwoven-wire design (Supera stent, IDEV Technologies, Inc, Webster, TX) to confer greater radial strength, flexibility, and fracture resistance. METHODS AND RESULTS: This prospective, multicenter, investigational device exemption, single-arm trial enrolled 264 patients with symptomatic peripheral artery disease undergoing percutaneous treatment of de novo or restenotic lesions of the superficial femoral or proximal popliteal (femoropopliteal) artery. Freedom from death, target lesion revascularization, or any amputation of the index limb at 30 days (+ 7 days) postprocedure was achieved in 99.2% (258/260) of patients (P < 0.001). Primary patency at 12 months (360 ± 30 days) was achieved in 78.9% (180/228) of the population (P < 0.001). Primary patency by Kaplan-Meier analysis at 12 months (360 days) was 86.3%. No stent fracture was observed by independent core laboratory analysis in the 243 stents (228 patients) evaluated at 12 months. Clinical assessment at 12 months demonstrated improvement by at least 1 Rutherford-Becker category in 88.7% of patients. CONCLUSIONS: The SUPERB Trial, an investigational device exemption study using an interwoven nitinol wire stent in the femoropopliteal artery, achieved the efficacy and safety performance goals predesignated by the Food and Drug Administration. On the basis of the high primary patency rate, absence of stent fracture, and significant improvements in functional and quality-of-life measures, the Supera stent provides safe and effective treatment of femoropopliteal lesions in symptomatic patients with peripheral artery disease. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00933270.


Assuntos
Ligas , Procedimentos Endovasculares/instrumentação , Artéria Femoral/fisiopatologia , Doença Arterial Periférica/terapia , Artéria Poplítea/fisiopatologia , Stents , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/fisiopatologia , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA