OBJECTIVES: To compare clinical outcomes of patients treated with overlapping versus non-overlapping Absorb BVS. BACKGROUND: Limited data are available on the clinical impact of stent overlap with the Absorb BVS bioresorbable stent. METHODS: We compared outcomes of patients receiving overlapping or non-overlapping Absorb BVS in the multicenter prospective RAI Registry. RESULTS: Out of 1,505 consecutive patients treated with Absorb BVS, 1,384 were eligible for this analysis. Of these, 377 (27%) were in the overlap group, and 1,007 (73%) in the non-overlap group. The most frequent overlap configuration was the marker-to-marker type (48%), followed by marker-over-marker (46%) and marker-inside-marker (6%) types. Patients of the overlap group had higher prevalence of multivessel disease and higher SYNTAX score, and required more frequently the use of intravascular imaging. At a median follow-up of 368 days, no difference was observed between overlap and non-overlap groups in terms of a device-related composite endpoint (cardiac death, TV-MI, ID-TLR) (5.8% vs. 4.1%, P = 0.20) or of a patient-related composite endpoint (any death, any MI, any revascularization) (15.4% vs. 12.5%, P = 0.18). Cardiac death (1.0% vs. 1.3%, P = 0.54), MI (4.5% vs. 3.6%, P = 0.51), TVR (4.5% vs. 3.6%, P = 0.51) and stent thrombosis (1.1 vs. 1.5%, P = 1.00) were also comparable between groups. When assessing outcomes of the overlap population according to overlap configurations used, no difference was observed in terms of the device- or patient-related composite endpoints. CONCLUSIONS: Outcomes of patients with or without overlapping BVS were comparable at mid-term follow-up despite higher angiographic complexity of the overlap subset. © 2017 Wiley Periodicals, Inc.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Everolimo/administração & dosagem , Isquemia Miocárdica/cirurgia , Intervenção Coronária Percutânea/instrumentação , Idoso , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Everolimo/efeitos adversos , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Prospectivos , Desenho de Prótese , Recidiva , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA