1.
Biomater Adv ; 149: 213397, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37023566

RESUMO

The regeneration of the ruptured scapholunate interosseous ligament (SLIL) represents a clinical challenge. Here, we propose the use of a Bone-Ligament-Bone (BLB) 3D-printed polyethylene terephthalate (PET) scaffold for achieving mechanical stabilisation of the scaphoid and lunate following SLIL rupture. The BLB scaffold featured two bone compartments bridged by aligned fibres (ligament compartment) mimicking the architecture of the native tissue. The scaffold presented tensile stiffness in the range of 260 ± 38 N/mm and ultimate load of 113 ± 13 N, which would support physiological loading. A finite element analysis (FEA), using inverse finite element analysis (iFEA) for material property identification, showed an adequate fit between simulation and experimental data. The scaffold was then biofunctionalized using two different methods: injected with a Gelatin Methacryloyl solution containing human mesenchymal stem cell spheroids (hMSC) or seeded with tendon-derived stem cells (TDSC) and placed in a bioreactor to undergo cyclic deformation. The first approach demonstrated high cell viability, as cells migrated out of the spheroid and colonised the interstitial space of the scaffold. These cells adopted an elongated morphology suggesting the internal architecture of the scaffold exerted topographical guidance. The second method demonstrated the high resilience of the scaffold to cyclic deformation and the secretion of a fibroblastic related protein was enhanced by the mechanical stimulation. This process promoted the expression of relevant proteins, such as Tenomodulin (TNMD), indicating mechanical stimulation may enhance cell differentiation and be useful prior to surgical implantation. In conclusion, the PET scaffold presented several promising characteristics for the immediate mechanical stabilisation of disassociated scaphoid and lunate and, in the longer-term, the regeneration of the ruptured SLIL.


Assuntos
Osso Semilunar , Osso Escafoide , Humanos , Polietilenotereftalatos , Ligamentos Articulares/cirurgia , Ligamentos Articulares/fisiologia , Osso Escafoide/cirurgia , Osso Semilunar/cirurgia , Articulação do Punho
2.
Med Phys ; 38(3): 1248-60, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21520837

RESUMO

PURPOSE: This study presents and validates a novel (non-ECG-triggered) MRI sequence based on spatial modulation of the magnetization (SPAMM) to noninvasively measure 3D (quasistatic) soft tissue deformations using only six acquisitions (three static and three indentations). In the current SPAMM tagged MRI approaches, data are typically constructed from many repeated motion cycles. This has so far restricted its application to the measurement of highly repeatable and periodic movements (e.g., cardiac deformation). In biomechanical applications where soft tissue deformation is artificially induced, often by indentation, significant repeatability constraints exist, and for clinical applications, discomfort and health issues generally preclude a large number of repetitions. METHODS: A novel (non-ECG-triggered) SPAMM tagged MRI sequence is presented, whereby a single 1-1 (first order) SPAMM set is acquired following a 3D transient field echo acquisition. Full 3D deformation measurement is achieved through the combination of only six acquisitions (three static and three motion cycles). The 3D deformation measurements were validated using quasistatic indentation tests and marker tracking in a silicone gel soft tissue phantom. In addition, the technique's ability to measure 3D soft tissue deformation in vivo was evaluated using indentation of the biceps region of the upper arm in a volunteer. RESULTS: Following comparison to marker tracking in the silicone gel phantom, the SPAMM tagged MRI based displacement measurement demonstrated subvoxel accuracy with a mean displacement difference of 72 microm and a standard deviation of 289 microm. In addition, precision of displacement magnitude was evaluated for both the phantom and the volunteer data. The standard deviations of the displacement magnitude with respect to the average displacement magnitude were 75 and 169 microm for the phantom and volunteer data, respectively. CONCLUSIONS: The subvoxel accuracy and precision demonstrated in the phantom in combination with the precision comparison between the phantom and the volunteer data provide confidence in the methods presented for measurement of soft tissue deformation in vivo. To the author's knowledge, since only six acquisitions are required, the presented methodology is the fastest SPAMM tagged MRI method currently available for the noninvasive measurement of quasistatic 3D soft tissue deformation.


Assuntos
Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Magnetismo , Braço , Marcadores Fiduciais , Humanos , Imageamento Tridimensional/normas , Imageamento por Ressonância Magnética/normas , Imagens de Fantasmas , Silicones , Fatores de Tempo
3.
Biomech Model Mechanobiol ; 20(4): 1317-1335, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33818678

RESUMO

Mechanical thrombectomy can be significantly affected by the mechanical properties of the occluding thrombus. In this study, we provide the first characterisation of the volumetric behaviour of blood clots. We propose a new hyperelastic model for the volumetric and isochoric deformation of clot. We demonstrate that the proposed model provides significant improvements over established models in terms of accurate prediction of nonlinear stress-strain and volumetric behaviours of clots with low and high red blood cell compositions. We perform a rigorous investigation of the factors that govern clot occlusion of a tapered vessel. The motivation for such an analysis is twofold: (i) the role of clot composition on the in vivo occlusion location is an open clinical question that has significant implications for thrombectomy procedures; (ii) in vitro measurement of occlusion location in an engineered tapered tube can be used as a quick and simple methodology to assess the mechanical properties/compositions of clots. Simulations demonstrate that both isochoric and volumetric behaviours of clots are key determinants of clot lodgement location, in addition to clot-vessel friction. The proposed formulation is shown to provide accurate predictions of in vitro measurement of clot occlusion location in a silicone tapered vessel, in addition to accurately predicting the deformed shape of the clot.


Assuntos
Fibrina/química , Acidente Vascular Cerebral/fisiopatologia , Trombectomia/métodos , Trombose/fisiopatologia , Força Compressiva , Simulação por Computador , Elasticidade , Eritrócitos , Análise de Elementos Finitos , Fricção , Humanos , Técnicas In Vitro , AVC Isquêmico/fisiopatologia , Resistência ao Cisalhamento , Silício , Silicones/química , Estresse Mecânico , Tromboembolia
4.
Adv Healthc Mater ; 10(14): e2100229, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34165264

RESUMO

Medical devices, such as silicone-based prostheses designed for soft tissue implantation, often induce a suboptimal foreign-body response which results in a hardened avascular fibrotic capsule around the device, often leading to patient discomfort or implant failure. Here, it is proposed that additive manufacturing techniques can be used to deposit durable coatings with multiscale porosity on soft tissue implant surfaces to promote optimal tissue integration. Specifically, the "liquid rope coil effect", is exploited via direct ink writing, to create a controlled macro open-pore architecture, including over highly curved surfaces, while adapting atomizing spray deposition of a silicone ink to create a microporous texture. The potential to tailor the degree of tissue integration and vascularization using these fabrication techniques is demonstrated through subdermal and submuscular implantation studies in rodent and porcine models respectively, illustrating the implant coating's potential applications in both traditional soft tissue prosthetics and active drug-eluting devices.


Assuntos
Próteses e Implantes , Silicones , Animais , Humanos , Teste de Materiais , Porosidade , Suínos
5.
Med Eng Phys ; 35(4): 486-99, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22819569

RESUMO

MRI is an ideal method for non-invasive soft tissue mechanical properties investigation. This requires mechanical excitation of the body's tissues and measurement of the corresponding boundary conditions such as soft tissue deformation inside the MRI environment. However, this is technically difficult since load application and measurement of boundary conditions requires MRI compatible actuators and sensors. This paper describes a novel MRI compatible computer controlled soft tissue indentor and optical Fibre Bragg Grating (FBG) force sensor. The high acquisition rate (100Hz) force sensor was calibrated for forces up to 15N and demonstrated a maximum error of 0.043N. Performance and MRI compatibility of the devices was verified using indentation tests on a silicone gel phantom and the upper arm of a volunteer. The computer controlled indentor provided a highly repeatable tissue deformation. Since the indentor and force sensor are composed of non-ferromagnetic materials, they are MRI compatible and no artefacts or temporal SNR reductions were observed. In a phantom study the mean and standard deviation of the temporal SNR levels without the indentor present were 500.18 and 207.08, respectively. With the indentor present the mean and standard deviation were 501.95 and 200.45, respectively. This computer controlled MRI compatible soft tissue indentation system with an integrated force sensor has a broad range of applications and will be used in the future for the non-invasive analysis of the mechanical properties of skeletal muscle tissue.


Assuntos
Imageamento por Ressonância Magnética , Teste de Materiais/instrumentação , Fenômenos Mecânicos , Músculo Esquelético/citologia , Fibras Ópticas , Fenômenos Ópticos , Anisotropia , Fenômenos Biomecânicos , Elasticidade , Movimento (Física) , Imagens de Fantasmas , Reprodutibilidade dos Testes , Silicones
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA