Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Am J Orthod Dentofacial Orthop ; 165(6): 663-670, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38520414

RESUMO

INTRODUCTION: The use of 3-dimensional (3D) printing techniques in fabricating crowns has increased the demand for bracket bonding onto these surfaces. The objective was to evaluate the shear bond strength (SBS) of orthodontic brackets bonded onto 3D-printed crowns using primer-incorporated orthodontic adhesives and 3D printing materials as orthodontic adhesives. METHODS: A total of 160 crowns were printed with two 3D printing materials, DentaTOOTH (Asiga, Sydney, Australia) (group A) and NextDent C&B Micro Filled Hybrid (3D Systems, Soesterberg, Netherlands) (group N). Each group was randomly divided into 4 adhesive subgroups (n = 20): Transbond XT (for groups A [ATX] and N [NTX]; 3M Unitek, Monrovia, Calif), Ortho Connect (for groups A [AOC] and N [NOC]; GC Corporation., Tokyo, Japan), Orthomite LC (for groups A [AOM] and N [NOM]; Sun Medical, Co Ltd, Moriyama, Shiga, Japan), and unpolymerized liquid state of 3D printing resin (for groups A [AA] and N [NN]). SBS was measured with a universal testing machine at a crosshead speed of 0.5 mm/min. The adhesive remnant index and the mode of failure were analyzed under the microscope. Statistical analysis was performed at a significance level of α = 0.05. RESULTS: When used as adhesives (AA and NN), 3D printing materials showed no statistically significant difference in SBS compared with Transbond XT (ATX and NTX, respectively). In group N, NN showed a significantly higher SBS than primer-incorporated orthodontic adhesives (NOC and NOM; P <0.001). Adhesive failures were only observed in primer-incorporated orthodontic adhesives (AOC, NOC, AOM, and NOM). CONCLUSIONS: Primer-incorporated orthodontic adhesives, as well as unpolymerized 3D printing materials employed as orthodontic adhesives on 3D-printed crowns, exhibited comparable bonding strength to Transbond XT without surface modification. Despite variations in adhesive-related factors, all measurements stayed within clinically acceptable ranges, highlighting the potential of these materials for orthodontic bonding on 3D-printed crowns, simplifying clinical procedures without compromising bond strength.


Assuntos
Coroas , Braquetes Ortodônticos , Impressão Tridimensional , Resistência ao Cisalhamento , Humanos , Colagem Dentária/métodos , Cimentos Dentários/química , Teste de Materiais , Análise do Estresse Dentário , Cimentos de Resina/química
2.
BMC Oral Health ; 23(1): 55, 2023 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-36717844

RESUMO

BACKGROUND: Safety issues for dental restorative composites are critical to material selection, but, limited information is available to dental practitioners. This study aimed to compare the chemical and biological characteristics of three nanohybrid dental composites by assessing filler particle analysis, monomer degree of conversion (DC), the composition of eluates, and cytotoxicity and reactive oxygen species (ROS) production in fibroblasts. METHODS: Three nanohybrid composites (TN, Tetric N-Ceram; CX, Ceram X Sphere Tec One; and DN, DenFil NX) were used. The size distribution and morphology of the filler particles were analysed using scanning electron microscopy (n = 5). The DC was measured via micro-Raman spectroscopy (n = 5). For the component analysis, methanol eluates from the light-polymerised composites were evaluated by gas chromatography/mass spectrometry (n = 3). The eluates were prepared from the polymerised composites after 24 h in a cell culture medium. A live/dead assay (n = 9) and Water-Soluble Tetrazolium-1 assay (n = 9) were performed and compared with negative and positive controls. The ROS in composites were compared with NC. Statistical significance in differences was assessed using a t-test and ANOVA (α = 0.05). RESULTS: Morphological variations in different-sized fillers were observed in the composites. The DC values were not significantly different among the composites. The amounts of 2-hydroxyethyl methacrylate (HEMA) were higher in TN than DN (p = 0.0022) and triethylene glycol dimethacrylate (TEGDMA) in CX was higher than in others (p < 0.0001). The lowest cell viability was shown in CX (p < 0.0001) and the highest ROS formation was detected in TN (p < 0.0001). CONCLUSIONS: Three nanohybrid dental composites exhibited various compositions of filler sizes and resin components, resulting in different levels of cytotoxicity and ROS production. Chemical compositions of dental composites can be considered with their biological impact on safety issues in the intraoral use of dental restorative composites. CX with the highest TEGDMA showed the highest cytotoxicity induced by ROS accumulation. DN with lower TEGDMA and HEMA presented the highest cell viability.


Assuntos
Odontólogos , Papel Profissional , Humanos , Espécies Reativas de Oxigênio , Resinas Compostas/toxicidade , Resinas Compostas/química , Metacrilatos , Ácidos Polimetacrílicos/química , Teste de Materiais , Bis-Fenol A-Glicidil Metacrilato/toxicidade , Materiais Dentários/toxicidade , Materiais Dentários/química
3.
Biomater Res ; 28: 0044, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38952715

RESUMO

Accurate measurement of gingiva's biomechanical properties in vivo has been an active field of research but remained an unmet challenge. Currently, there are no noninvasive tools that can accurately quantify tensile and shear moduli, which govern gingival health, with sufficiently high accuracy. This study presents the application of high-frequency optical coherence elastography (OCE) for characterizing gingival tissue in both porcine models and human subjects. Dynamic mechanical analysis, histology studies, and strain analysis are performed to support the OCE result. Our findings demonstrate substantial differences in tissue stiffness between supra-dental and inter-dental gingiva, validated by dynamic mechanical analysis and OCE. We confirmed the viscoelastic, nearly linear, and transverse-isotropic properties of gingiva in situ, establishing the reliability of OCE measurements. Further, we investigated the effects of tissue hydration, collagen degradation, and dehydration on gingival stiffness. These conditions showed a decrease and increase in stiffness, respectively. While preliminary, our study suggests OCE's potential in periodontal diagnosis and oral tissue engineering, offering real-time, millimeter-scale resolution assessments of tissue stiffness, crucial for clinical applications and biomaterial optimization in reconstructive surgeries.

4.
Dent Mater J ; 43(3): 437-445, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38692906

RESUMO

This study aimed to investigate the colorimetric properties of newly developed composites for dental trauma splints using various staining solutions during the clinical splinting period. The clear shades of G-Fix (GF), Ortho Connect Flow (OC), Light Fix (LF), and Filtek Z350XT (FZ) were fabricated into 96 disk-shaped specimens. Specimens from each composite group were stored in distilled water, coffee, tea, and red wine solutions at 37ºC. CIE values were measured using a spectrophotometer at 24 h after specimen preparation and at 1 day, 1 week, 2 weeks, 3 weeks, and 4 weeks after storage in each solution. Color differences and translucency parameters were calculated using the initial and measured values. Within the experiment period, the color differences of GF, OC, and LF compared to the initial measurement were smaller than that for FZ for all staining solutions except distilled water. There were no significant color differences between the GF, OC, and LF groups.


Assuntos
Café , Cor , Colorimetria , Resinas Compostas , Teste de Materiais , Espectrofotometria , Resinas Compostas/química , Chá , Vinho , Água/química , Propriedades de Superfície , Humanos , Poliuretanos/química
5.
PLoS One ; 17(6): e0268791, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35653310

RESUMO

OBJECTIVE: This study aimed to evaluate the efficacy of three sonic irrigation systems for removal of calcium hydroxide dressing from the apical root canal. MATERIALS AND METHODS: A total of 96 single-rooted teeth in three categories of root canal curvatures (straight: 0-5°, moderate: 6-20°, and severe: > 20°) were allocated to four groups: conventional needle irrigation, EndoActivator, EQ-S, and Vibringe. The root canals were instrumented using Protaper NEXT and filled with calcium hydroxide. After removal of calcium hydroxide, the remaining volume of calcium hydroxide was measured by micro-CT analysis. Data were compared among root canal curvatures and irrigation systems using the Kruskal-Wallis test and Mann-Whitney test (p < .05). The oscillating range of each irrigation system was measured using light-coupled motion tracking. RESULTS: The volumes of calcium hydroxide remaining in the canals with severe curvature were significantly higher than in those of straight curvature (p < .05). In the canals of moderate or severe curvature, EQ-S showed the highest removal percentage, followed by EndoActivator, Vibringe, and needle irrigation (p < .05). Light-coupled tracking showed the largest oscillating range in EQ-S (p < .05). CONCLUSIONS: Sonically activated irrigation systems with a flexible tip can be beneficial for calcium hydroxide intracanal dressing removal in the curved apical canals.


Assuntos
Hidróxido de Cálcio , Cavidade Pulpar , Cavidade Pulpar/diagnóstico por imagem , Preparo de Canal Radicular , Tratamento do Canal Radicular , Microtomografia por Raio-X
6.
Dent Mater J ; 41(1): 37-44, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34471038

RESUMO

This study aimed to determine functionality and mechanical properties of dental splints. Five splints were tested: a control splint Filtek Z350XT (ZF), two splints with G-Fix (GF) and Light Fix (LF), and two wire-composite splints with ZF (ZW) and Ortho Connect Flow (CW). Periotest values, elastic modulus, flexural, compressive, and diametral tensile strength were measured. ZW and CW showed no significant differences in flexibility in labial or occlusal pressure of upper central incisors. LF, GF, and ZF did not differ in labial or palatal pressure. ZW and CW had higher flexibility than LF, GF, and ZF. LF had the lowest flexural and compressive strength but the highest diametral tensile strength. This study showed that ZW and CW might be options for flexible splints, whereas LF and GF would be options for rigid splints. Additionally, CW and LF/GF might be simpler alternatives to ZW and ZF, respectively.


Assuntos
Resinas Compostas , Mobilidade Dentária , Análise do Estresse Dentário , Módulo de Elasticidade , Humanos , Incisivo , Teste de Materiais , Contenções , Resistência à Tração
7.
Materials (Basel) ; 14(5)2021 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-33800321

RESUMO

The purpose of this study was to observe whether the repetitive firing of dental zirconia caused changes in surface characteristics, S. mutans viability, and optical properties of zirconia. Dental zirconia blocks were sintered and randomly distributed into seven experimental groups: F0-F6. Except for F0, which only went through sintering, the additive firing was performed in order for F1-F6. Surface roughness, contact angle, S. mutans viability by fluorescence, and translucency parameter were measured. They were all highest after sintering (F0) and decreased after additive firings (F1-F6). The additive firing of zirconia after sintering decreased surface roughness, contact angle, S. mutans viability, and translucency. The number of firings after the first firing was not found to be critical in surface characteristics, S. mutans viability, and optical property. Changes in surface characteristics might have led to a decrease in S. mutans viability, while the change of translucency was not clinically significant. This implies that additive firing may prevent secondary caries under zirconia restorations, not compromising esthetic appearance.

8.
Materials (Basel) ; 14(6)2021 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-33803596

RESUMO

With the advent of 3D printing technologies in dentistry, the optimization of printing conditions has been of great interest, so this study analyzed the accuracy of 3D-printed temporary restorations of different sizes produced by digital light processing (DLP) and liquid crystal display (LCD) printers. Temporary restorations of 2-unit, 3-unit, 5-unit, 6-unit, and full-arch cases were designed and printed from a DLP printer using NextDent C&B or an LCD printer using Mazic D Temp (n = 10 each). The restorations were scanned, and each restoration standard tessellation language (STL) file was superimposed on the reference STL file, by the alignment functions, to evaluate the trueness through whole/point deviation. In the whole-deviation analysis, the root-mean-square (RMS) values were significantly higher in the 6-unit and full-arch cases for the DLP printer and in the 5-unit, 6-unit, and full-arch cases for the LCD printer. The significant difference between DLP and LCD printers was found in the 5-unit and full-arch cases, where the DLP printer exhibited lower RMS values. Color mapping demonstrated less shrinkage in the DLP printer. In the point deviation analysis, a significant difference in direction was exhibited in all the restorations from the DLP printer but only in some cases from the LCD printer. Within the limitations of this study, 3D printing was most accurate with less deviation and shrinkage when a DLP printer was used for short-unit restorations.

9.
Materials (Basel) ; 13(18)2020 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-32947875

RESUMO

The purpose of this study is to evaluate the shear bond strength (SBS) of a primer-treated ceramic bracket on dental zirconia and to compare it with conventional ceramic bracket bonding on surface-treated zirconia. Sintered and finished dental zirconia was sandblasted. Samples were divided according to the treated surfaces: no treatment (X), ceramic primer on zirconia (Z), ceramic primer on bracket base (B), and ceramic primer on both zirconia and bracket base (ZB). The ceramic bracket was bonded on zirconia and SBS was measured before (T0) and after 10,000 cycles of thermocycling (Tf). The failed surfaces were examined under field emission scanning electron microscope (FE-SEM), and adhesive remnant index (ARI) was evaluated. SBS was significantly higher in ZB and significantly lower in X in both T0 and Tf. There was no significant difference between Z and B. In X and B, adhesive failure occurred while ZB showed mixed failures. There was no apparent change in the zirconia surface except for the existence of some adhesive and resin remnants. The application of ceramic primer on the bracket base increased the bonding strength to the level of conventional bonding with fewer adhesive remnants. The highest bonding strength was obtained when the primer-treated bracket was bonded on the primer-treated zirconia.

10.
Materials (Basel) ; 13(21)2020 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-33105868

RESUMO

This study compares the color stability of dental reinforced computer-aided design/computer-aided manufacturing (CAD/CAM) hybrid composite blocks to that of regular blocks. One hundred fifty disc-type specimens (n = 15) were prepared from five sets of hybrid composite blocks (Cerasmart-200/Cerasmart-300, KZR-CAD HR/KZR-CAD HR3, Estelite Block/ Estelite-P Block, Avencia Block/Avencia-P Block, Mazic Duro/Duro Ace). The specimen color and translucency parameter (TP) were assessed using a spectrophotometer before and after immersion in staining solutions (water, 10% ethanol, simulated red wine). Changes in color (ΔE) and translucency (ΔTP) of specimens were calculated. The data were analyzed using the analysis of variance (ANOVA) and Tukey's post hoc test (p < 0.05). Microstructural features of the hybrid composite blocks were also examined using FE-SEM. Immersion in deionized water or 10% ethanol made no significant color or translucency changes (except for Avencia-P Block); however, the simulated red wine caused significant changes to the color and translucency of almost all specimens, especially after 4 weeks of immersion. The reinforced hybrid blocks (except for Estelite-P Block and Duro Ace) showed lower color stability than corresponding regular blocks. Avencia-P Block showed significantly reduced color stability compared to Avencia Block. Even in deionized water and 10% ethanol, Avencia-P Block showed perceptible ΔE and decreased translucency. Estelite Block/ Estelite-P Block and Mazic Duro/Duro Ace showed better color stability than the other materials tested.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA