Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
BMC Med ; 20(1): 406, 2022 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-36280827

RESUMO

BACKGROUND: The diagnostic accuracy of unsupervised self-testing with rapid antigen diagnostic tests (Ag-RDTs) is mostly unknown. We studied the diagnostic accuracy of a self-performed SARS-CoV-2 saliva and nasal Ag-RDT in the general population. METHODS: This large cross-sectional study consecutively included unselected individuals aged ≥ 16 years presenting for SARS-CoV-2 testing at three public health service test sites. Participants underwent molecular test sampling and received two self-tests (the Hangzhou AllTest Biotech saliva self-test and the SD Biosensor nasal self-test by Roche Diagnostics) to perform themselves at home. Diagnostic accuracy of both self-tests was assessed with molecular testing as reference. RESULTS: Out of 2819 participants, 6.5% had a positive molecular test. Overall sensitivities were 46.7% (39.3-54.2%) for the saliva Ag-RDT and 68.9% (61.6-75.6%) for the nasal Ag-RDT. With a viral load cut-off (≥ 5.2 log10 SARS-CoV-2 E-gene copies/mL) as a proxy of infectiousness, these sensitivities increased to 54.9% (46.4-63.3%) and 83.9% (76.9-89.5%), respectively. For the nasal Ag-RDT, sensitivities were 78.5% (71.1-84.8%) and 22.6% (9.6-41.1%) in those symptomatic and asymptomatic at the time of sampling, which increased to 90.4% (83.8-94.9%) and 38.9% (17.3-64.3%) after applying the viral load cut-off. In those with and without prior SARS-CoV-2 infection, sensitivities were 36.8% (16.3-61.6%) and 72.7% (65.1-79.4%). Specificities were > 99% and > 99%, positive predictive values > 70% and > 90%, and negative predictive values > 95% and > 95%, for the saliva and nasal Ag-RDT, respectively, in most analyses. Most participants considered the self-performing and result interpretation (very) easy for both self-tests. CONCLUSIONS: The Hangzhou AllTest Biotech saliva self Ag-RDT is not reliable for SARS-CoV-2 detection, overall, and in all studied subgroups. The SD Biosensor nasal self Ag-RDT had high sensitivity in individuals with symptoms and in those without prior SARS-CoV-2 infection but low sensitivity in asymptomatic individuals and those with a prior SARS-CoV-2 infection which warrants further investigation.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Estudos Transversais , Teste para COVID-19 , Saliva , Sensibilidade e Especificidade , Antígenos Virais
2.
Open Forum Infect Dis ; 11(4): ofae113, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38560600

RESUMO

Background: Diagnosis of cutaneous leishmaniasis (CL) usually relies on invasive samples, but it is unclear whether more patient-friendly tools are good alternatives for diverse lesions when used with polymerase chain reaction (PCR). Methods: Patients with suspected CL were enrolled consecutively in a prospective diagnostic accuracy study. We compared dental broach, tape disc, and microbiopsy samples with PCR as index tests, using PCR with skin slit samples as reference test. Subsequently, we constructed a composite reference test including microscopy, the 3 index tests and skin slit PCR, and we compared these same tests with the composite reference test. We assessed diagnostic accuracy parameters with 95% confidence intervals for all comparisons. Results: Among 344 included patients, 282 (82.0%) had CL diagnosed, and 62 (18.0%) CL absence, by skin slit PCR. The sensitivity and specificity by PCR were 89.0% (95% confidence interval, 84.8%-92.1%) and 58.1% (45.7%-69.5%), respectively, for dental broach, 96.1% (93.2%-97.8%) and 27.4% (17.9%-39.6%) for tape disc, and 74.8% (66.3%-81.7%) and 72.7% (51.8%-86.8%) for microbiopsy. Several reference test-negative patients were consistently positive with the index tests. Using the composite reference test, dental broach, and skin slit had similar diagnostic performance. Discussion: Dental broach seems a less invasive but similarly accurate alternative to skin slit for diagnosing CL when using PCR. Tape discs lack specificity and seem unsuitable for CL diagnosis without cutoff. Reference tests for CL are problematic, since using a single reference test is likely to miss true cases, while composite reference tests are often biased and impractical as they require multiple tests.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA