Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Mater Sci Mater Med ; 35(1): 28, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38833196

RESUMO

AIM: This study aimed to comprehensively assess the biocompatibility and toxicity profiles of poly(methyl methacrylate) (PMMA) and its monomeric unit, methyl methacrylate (MMA), crucial components in dental materials for interim prosthetic restorations. METHODOLOGY: Molecular docking was employed to predict the binding affinities, energetics, and steric features of MMA and PMMA with selected receptors involved in bone metabolism and tissue development, including RANKL, Fibronectin, BMP9, NOTCH2, and other related receptors. The HADDOCK standalone version was utilized for docking calculations, employing a Lamarckian genetic algorithm to explore the conformational space of ligand-receptor interactions. Furthermore, molecular dynamics (MD) simulations over 100 nanoseconds were conducted using the GROMACS package to evaluate dynamic actions and structural stability. The LigandScout was utilized for pharmacophore modeling, which employs a shape-based screening approach to identify potential ligand binding sites on protein targets. RESULTS: The molecular docking studies elucidated promising interactions between PMMA and MMA with key biomolecular targets relevant to dental applications. MD simulation results provided strong evidence supporting the structural stability of PMMA complexes over time. Pharmacophore modeling highlighted the significance of carbonyl and hydroxyl groups as pharmacophoric features, indicating compounds with favorable biocompatibility profiles. CONCLUSION: This study underscores the potential of PMMA in dental applications, emphasizing its structural stability, molecular interactions, and safety considerations. These findings lay a foundation for future advancements in dental biomaterials, guiding the design and optimization of materials for enhanced biocompatibility. Future directions include experimental validation of computational findings and the development of PMMA-based dental materials with improved biocompatibility and clinical performance.


Assuntos
Materiais Biocompatíveis , Materiais Dentários , Teste de Materiais , Simulação de Acoplamento Molecular , Simulação de Dinâmica Molecular , Polimetil Metacrilato , Materiais Biocompatíveis/química , Polimetil Metacrilato/química , Materiais Dentários/química , Humanos , Ligantes , Simulação por Computador , Sítios de Ligação
2.
BMC Med Educ ; 24(1): 169, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38389076

RESUMO

BACKGROUND: Selecting the ideal tooth shade is essential to the success of aesthetic dental restorations. Students' cognitive abilities are involved in the multifaceted and intricate process of shade matching. Hence, the present study aimed to assess and compare the shade-matching ability of undergraduate dental students in various years of dental education under clinical and correcting light. METHODS: This comparative cross-sectional study was instigated amongst male 4th, 5th, and 6th-year students of the dental complex of King Faisal University, Kingdom of Saudi Arabia. A total of 72 male dental students assessed the shade under clinical (fluorescent light) and correcting light (handheld Dental Base Light) by using VITA Classical shade guides. Statistical analysis was done using SPSS version 23 (Armonk, NY, USA). The Chi-square test was used to evaluate the association between correct and incorrect shade matching under correcting and clinical light. RESULTS: Out of 72 male students, 22(30.6%) were from the 4th year, 26(36.1%) were from the 5th year, and 24(33.3%) were from the 6th year, with a mean age of 22.92 ± 1.01 years. The majority of the 6th-year students selected shade of anterior tooth # 11 correctly under clinical and correcting light, and 3(12.5%) students selected incorrectly under clinical and correcting light, with a statistically significant association among them (p = 0.004). As far as the shade selection of the posterior tooth is concerned, a statistically significant difference was observed under clinical light among all clinical students (p = 0.008). CONCLUSION: The clinical performance of dental students in shade matching improved with advancing years of dental education. Additionally, the shade matching ability of all groups of dental students was superior under correcting light compared to conditions under clinical light.


Assuntos
Percepção de Cores , Estudantes de Odontologia , Humanos , Masculino , Adulto Jovem , Adulto , Estudos Transversais , Pigmentação em Prótese , Arábia Saudita
3.
J Oral Rehabil ; 51(7): 1250-1302, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38570927

RESUMO

BACKGROUND: Various medical conditions and the drugs used to treat them have been shown to impede or complicate dental implant surgery. It is crucial to carefully monitor the medical status and potential post-operative complications of patients with systemic diseases, particularly elderly patients, to minimize the risk of health complications that may arise. AIM: The purpose of this study was to review the existing evidence on the viability of dental implants in patients with systemic diseases and to provide practical recommendations to achieve the best possible results in the corresponding patient population. METHODS: The information for our study was compiled using data from PubMed, Scopus, Web of Science and Google Scholar databases and searched separately for each systemic disease included in our work until October 2023. An additional manual search was also performed to increase the search sensitivity. Only English-language publications were included and assessed according to titles, abstracts and full texts. RESULTS: In total, 6784 studies were found. After checking for duplicates and full-text availability, screening for the inclusion criteria and manually searching reference lists, 570 articles remained to be considered in this study. CONCLUSION: In treating patients with systemic conditions, the cost-benefit analysis should consider the patient's quality of life and expected lifespan. The success of dental implants depends heavily on ensuring appropriate maintenance therapy, ideal oral hygiene standards, no smoking and avoiding other risk factors. Indications and contraindications for dental implants in cases of systemic diseases are yet to be more understood; broader and hardcore research needs to be done for a guideline foundation.


Assuntos
Implantes Dentários , Humanos , Implantes Dentários/efeitos adversos , Qualidade de Vida , Implantação Dentária Endóssea/efeitos adversos , Complicações Pós-Operatórias/prevenção & controle , Análise Custo-Benefício , Fatores de Risco , Assistência Odontológica para Doentes Crônicos
4.
J Prosthet Dent ; 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38772783

RESUMO

STATEMENT OF PROBLEM: Additive (3-dimensional printing) and subtractive (milling) methods are digital approaches to fabricating zirconia restorations. Comparisons of their resultant fabrication accuracy and restoration fit are lacking. PURPOSE: The purpose of this systematic review and meta-analysis was to evaluate the accuracy and fit of monolithic zirconia crowns fabricated by 3-dimensional printing and milling. MATERIAL AND METHODS: The PubMed (Medline), Scopus, Embase, Web of Science, Cochrane Library, and Google Scholar databases were searched up to August 2023. Eligible records were included, and the standardized mean difference (SMD) analyzed 4 outcomes: marginal fit, intaglio fit, trueness, and precision. Publication bias was analyzed with Trim-and-fill, the Egger regression test, and Begg funnel plot. Methodological quality was rated using the QUIN tool. RESULTS: A total of 15 publications were found eligible out of the initial 6539 records. The 3-dimensional printing group demonstrated a lower marginal fit (SMD=1.46, 95% CI=[0.67, 2.26], P<.001; I2=83%, P<.001) and trueness (SMD=0.69, 95% CI=[0.20, 1.18], P=.006; I2=88%, P<.001) and a significantly higher precision (SMD=-2.19, 95% CI=[-2.90, -1.48], P<.001; I2=56%, P=.045). The intaglio fit did not differ significantly across the study groups (SMD=0.77, 95% CI=[-0.22, 1.77], P=.127; I2=87%, P<.001). CONCLUSIONS: Given the high degree of heterogeneity, it can be cautiously concluded that while 3-dimensional printing led to greater precision, the outcomes of the 2 accuracy and adaptation parameters most crucial to the longevity of the restorations-trueness and marginal fit-showed the superiority of the milling technique.

5.
BMC Oral Health ; 24(1): 676, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38858745

RESUMO

BACKGROUND: Clinicians often utilize both flowable and packable composites concurrently in bonding fixed retainers. Thus, this study aimed to assess the synergistic effect of these composites in the bonding process. METHODS: This in vitro study divided specimens into three groups: flowable composite (nano-hybrid, Tetric N-Flow, Ivoclar Vivadent), packable composite (nano-hybrid, Tetric N-ceram, Ivoclar Vivadent), and combined use of flowable and packable composite. Shear bond strength (SBS), adhesive remnant index (ARI), and wire pull-out resistance were compared among the groups. Statistical analyses were conducted using ANOVA and Tukey tests to compare study groups. Additionally, Chi-square and Kruskal-Wallis tests were employed to analyze the ARI index among the groups. RESULTS: ANOVA results indicated no statistically significant differences among test groups (P = 0.129) regarding SBS. However, a significant difference existed between flowable and packable composite groups (P = 0.01) regarding ARI scores. Among the study groups, flowable composite exhibited the highest frequencies of ARI scores of 1 and 2, whereas packable composite showed the highest frequency of ARI scores of 0. The combined group had higher frequencies of ARI scores of 0 and 1 compared to the flowable composite. The wire pull-out test revealed that the combined application of flowable and packable composite resulted in significantly lower detachments compared to the packable composite alone (P = 0.008). However, no significant differences were observed in the comparisons between the flowable-packable (P = 0.522) and combined-flowable (P = 0.128) groups. CONCLUSION: The combined use of flowable and packable composites for fixed retainers demonstrated adequate shear bond strength and ideal ARI scores, suggesting it as a suitable adhesive system for bonding orthodontic fixed retainers.


Assuntos
Resinas Compostas , Teste de Materiais , Contenções Ortodônticas , Resistência ao Cisalhamento , Resinas Compostas/química , Técnicas In Vitro , Colagem Dentária/métodos , Análise do Estresse Dentário , Humanos
6.
BMC Oral Health ; 24(1): 192, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38321523

RESUMO

BACKGROUND: Moebius syndrome (MS) is a rare, non-progressive, neuromuscular, congenic disease involving the oral maxillofacial region. The present study aimed to describe the oral and extraoral findings in MS patients and their comprehensive dental management. METHODS: A digital search was carried out in PubMed/MEDLINE, Scopus, Web of Science, and Google Scholar, restricted to articles in English from Jan 01, 2000, to Apr 02, 2023, following PRISMA guidelines. The methodological quality of the studies was evaluated following the JBI guidelines. Qualitative analysis was carried out on the overall result, extraoral and intraoral manifestations, considering dental management as appropriate. RESULTS: Twenty-three studies were included, and a total of 124 cases of patients with MS were analyzed. The 82% of patients with MS were younger than 15 years of age. The most frequent extraoral manifestations were blinking and visual problems (78,22%), malformations of the upper and lower limbs (58,22%), bilateral facial paralysis (12,90%), lack of facial expression (12.09%), and unilateral facial paralysis (6,45%). On the other hand, the most frequent oral manifestations were tongue deformities (78,22%), micrognathia (37,90%), labial incompetence (36,29%), cleft palate (22,87%), gothic palate (16,12%), microstomia (15,32%), anterior open bite (15,32%), dental caries (8,87%), and periodontal disease (8,06%). The majority of MS patients were treated by pediatric dentistry (60,86%), using a surgical approach (56,52%), and orthodontic and orthopedic maxillary (43,47%) followed by restorative (39,13%), and periodontal treatments (21,73%). CONCLUSIONS: This systematic review demonstrates that patients with MS present a wide variety of oral and extraoral manifestations, for which dental treatments are planned and tailored to each patient in accordance with oral manifestations. These treatments encompass problem resolution and oral health maintenance, incorporating recent techniques in managing and treating patients with MS.


Assuntos
Fissura Palatina , Cárie Dentária , Paralisia Facial , Síndrome de Möbius , Criança , Humanos , Assistência Odontológica
7.
BMC Oral Health ; 24(1): 693, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38877446

RESUMO

BACKGROUND: The effectiveness of alveolar ridge preservation on bone regeneration and tissue healing has been thoroughly documented in the literature. This study aimed to evaluate the peri-implant soft and hard tissue changes after alveolar ridge preservation using either platelet-rich fibrin (PRF) or freeze-dried bone allograft (FDBA) over a 12-month period following the prosthetic loading of implants. METHODS: In this randomized clinical trial, 40 individuals were recruited for alveolar ridge preservation using (1) FDBA or (2) PRF in incisal/premolar areas. At two follow-up sessions (six- and 12-months post-implant insertion), radiographic imaging and clinical examinations assessed marginal bone loss and soft tissue factors, including gingival recession and bleeding on probing. The differences between study groups were analyzed using Generalized estimating Equations, the Binary logistic regression model, and Cochran's Q test. RESULTS: There was a statistically significant difference regarding gingival recession at both follow-up evaluations; values in the PRF group were considerably lower compared to the FDBA group (p < 0.05). The mean values for vertical marginal bone loss and bleeding on probing showed no significant differences between the two study groups (p > 0.05). CONCLUSIONS: Except for gingival recession, applying PRF yielded comparable clinical results to FDBA after one year of implant loading and could be recommended as a potential biomaterial for alveolar ridge preservation following tooth extractions. CLINICAL TRIAL REGISTRATION: The research protocol was registered in the Protocol Registration and Results System on 13/08/2021, available at https://clinicaltrials.gov/ (NCT05005377).


Assuntos
Perda do Osso Alveolar , Transplante Ósseo , Liofilização , Fibrina Rica em Plaquetas , Humanos , Feminino , Masculino , Transplante Ósseo/métodos , Pessoa de Meia-Idade , Perda do Osso Alveolar/prevenção & controle , Perda do Osso Alveolar/diagnóstico por imagem , Adulto , Aumento do Rebordo Alveolar/métodos , Retração Gengival/prevenção & controle , Retração Gengival/cirurgia , Aloenxertos
8.
BMC Oral Health ; 24(1): 401, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38553673

RESUMO

BACKGROUND: This study aimed to evaluate dentist perceptions of attractive smiles in the Pakistani population, considering different dental proportions. METHODS: Maxillary casts and digital images were used to create symmetrical representations of anterior teeth. dentists' preferences for good and bad teeth proportions, width/height ratios, and various dental proportions (golden, recurring esthetic dental (RED), golden percentage, Preston, and local/observed) were assessed using one sample and paired t-test. The Chi-square test was used to determine the gender disparities and factors affecting smile attractiveness. A p-value of ≤ 0.05 was taken as significant. RESULTS: The RED proportion emerged as the preferred choice for normal-sized teeth, with specialists and general dentists favoring it over the golden proportion. For tall teeth, the golden proportion was predominantly preferred. The golden percentage received limited preference for aesthetic smile construction. CONCLUSIONS: The smiles created using the principles of RED proportion were opted as the most attractive by local dentists. Factors such as tooth arrangement, color, and midline were highlighted as essential considerations in aesthetic smile construction.


Assuntos
Estética Dentária , Incisivo , Humanos , Paquistão , Sorriso , Maxila , Recidiva , Odontólogos
9.
BMC Oral Health ; 24(1): 29, 2024 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-38182999

RESUMO

BACKGROUND: Sleep bruxism is a prevalent condition in dentistry practice, characterized by involuntary grinding or clenching of the teeth during sleep. Several therapies, including occlusal splints, have been used to manage sleep bruxism and temporomandibular disorders, including occlusal splints. This study aimed to compare the effectiveness of different occlusal splints in managing sleep bruxism. METHODS: The PICO framework encompasses the characterization of the population, intervention, comparison, and pertinent outcomes. A comprehensive and systematic literature review was conducted on PubMed, Scopus, and Google Scholar to identify grey literature. The search specifically targeted scientific studies published before September 20, 2023. The Cochrane Collaboration Risk of Bias Tool assessed the accuracy of the included Randomized Control Trials (RCTs). The modified Newcastle-Ottawa Scale assessed non-randomized studies. Data were systematically extracted, synthesized, and reported thematically. RESULTS: Out of the total of 808 articles that were evaluated, only 15 articles were found to meet the specified inclusion criteria. Adjustable splints, such as full-occlusion biofeedback splints, were more effective in reducing sleep bruxism episodes, improving patient-reported symptoms, and enhancing overall well-being. The impact of different occlusal sprints on electromyographic activity varies, and potential adverse effects should be considered individually. CONCLUSIONS: This review provides valuable insights into the effectiveness of occlusal splints in managing sleep bruxism. The results of this study indicate that occlusal splint therapy is a viable treatment approach for sleep bruxism.


Assuntos
Placas Oclusais , Bruxismo do Sono , Humanos , Bruxismo do Sono/terapia , Sono
10.
BMC Oral Health ; 24(1): 366, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38515128

RESUMO

BACKGROUND: The success of implants in the socket shield technique relies on stress experienced by root fragments within the socket. Although there is no consensus on optimal root fragment thickness, varying thicknesses and dynamic implant placement induce stress in various directions and degrees. This study aimed to assess biomechanical response and stress distribution across different root fragment thicknesses in the socket shield procedure. METHODS: This in vitro study was conducted to assess and compare the stress distribution on residual root structures of varying thicknesses positioned within the labial aspect of the maxillary incisor socket during immediate implant placement of standard dimensions. The procedure involved applying an insertional torque of 40 Ncm, and the analysis was conducted using finite element analysis software. RESULTS: Utilizing the Numerical Technique with Abaqus software for explicit dynamics, von Mises stress and principal strain were analyzed on the root structure and bone under nonlinear contact conditions during implant torque application. For Model A, a loading torque of 40 Ncm was applied vertically on the implant, along with a horizontal force of 20 N on the root structure and bone. Results indicated maximum stress of 12.68 MPa on the root structure with a thickness of 0.5 mm and 5.61 MPa on the bone, with principal strains of 6.82E-03 and 4.10E-03, respectively. In Model B, with a root structure thickness of 1.0 mm, the maximum stress increased to 19.70 MPa, while the bone stress rose to 9.51 MPa, with principal strains of 1.03E-02 and 6.09E-03. Model C, with a root structure thickness of 1.5 mm, exhibited a maximum stress of 21.58 MPa on the root and 10.12 MPa on the bone, with principal strains of 1.16E-02 and 6.10E-03. Lastly, in Model D, with a root structure thickness of 2.0 mm, the maximum stress on the root structure and bone escalated to 28.74 MPa and 11.38 MPa, respectively, with principal strains of 1.55E-02 and 8.31E-03. CONCLUSIONS: As the thickness of the shield increases (ranging from 0.5 to 2 mm) in socket shield procedures with immediate implant placement, both stress on the root fragment and bone and principal micro-strain escalate. However, employing a shield thickness within the range of 0.5 to 2 mm does not lead to any adverse stress generation on the residual root fragment. However, for enhanced safety, it is recommended to restrict the maximum diameter and extension of the root fragment to 1.5 mm when considering implant sizes and socket diameter for the socket shield technique.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Carga Imediata em Implante Dentário , Humanos , Análise de Elementos Finitos , Alvéolo Dental/cirurgia , Análise do Estresse Dentário
11.
BMC Oral Health ; 24(1): 54, 2024 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-38195442

RESUMO

BACKGROUND: The effectiveness of newly developed elastomeric polymer hybrid siloxane (PVES), which combines the properties of polyethylene (PE) and polyvinyl siloxane (PVS) elastomers, has been a subject of interest in recent studies. This study aimed to assess the physical properties of hybrid PVES materials by analyzing existing data from recent studies on this topic. METHODS: A systematic literature search was conducted to retrieve peer-reviewed articles published up to February 5, 2023. The population, intervention, comparison, and pertinent outcomes were specified under the PICO framework. The primary data analysis was performed in Microsoft Excel, while statistical analysis used Meta-Essentials. RESULTS: Of the 1152 articles assessed, 14 met the inclusion criteria. The meta-analysis of the selected studies indicated that polyether (PE) and polyvinyl siloxane (PVS) were highly correlated (two-tailed p-values of 0.000 and 0.001, respectively) with the improved tensile strength of vinyl polyether siloxane (PVES) with a significantly positive effect size. Similarly, the hydrophilic characteristics of PVES were significantly improved compared to those of PE and PVS. PE was a significant contributor to the hydrophilic characteristics of PVES, with a two-tailed p-value of 0.000. The effect size was highly positive for hydrophilicity but showed high heterogeneity. It was also observed that the dimensional accuracy of PVES was comparable to those of PE and PVS, with no statistically significant differences among the three materials. CONCLUSIONS: PVES showed promising features, with improved tensile strength and hydrophilic characteristics compared to those of PE and PVS.


Assuntos
Polietileno , Siloxanas , Humanos , Elastômeros , Pais
12.
BMC Oral Health ; 24(1): 66, 2024 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-38200473

RESUMO

BACKGROUND: Three-dimensional (3D) printing technology has revolutionized dentistry, particularly in fabricating provisional restorations. This systematic review and meta-analysis aimed to thoroughly evaluate the flexural strength of provisional restorations produced using 3D printing while considering the impact of different resin materials. METHODS: A systematic search was conducted across major databases (ScienceDirect, PubMed, Web of Sciences, Google Scholar, and Scopus) to identify relevant studies published to date. The inclusion criteria included studies evaluating the flexural strength of 3D-printed provisional restorations using different resins. Data extraction and quality assessment were performed using the CONSORT scale, and a meta-analysis was conducted using RevMan 5.4 to pool results. RESULTS: Of the 1914 initially identified research articles, only 13, published between January 2016 and November 2023, were included after screening. Notably, Digital Light Processing (DLP) has emerged as the predominant 3D printing technique, while stereolithography (SLA), Fused Deposition Modeling (FDM), and mono-liquid crystal displays (LCD) have also been recognized. Various printed resins have been utilized in different techniques, including acrylic, composite resins, and methacrylate oligomer-based materials. Regarding flexural strength, polymerization played a pivotal role for resins used in 3D or conventional/milled resins, revealing significant variations in the study. For instance, SLA-3D and DLP Acrylate photopolymers displayed distinct strengths, along with DLP bisacrylic, milled PMMA, and conventional PMMA. The subsequent meta-analysis indicated a significant difference in flexure strength, with a pooled Mean Difference (MD) of - 1.25 (95% CI - 16.98 - 14.47; P < 0.00001) and a high I2 value of 99%, highlighting substantial heterogeneity among the studies. CONCLUSIONS: This study provides a comprehensive overview of the flexural strength of 3D-printed provisional restorations fabricated using different resins. However, further research is recommended to explore additional factors influencing flexural strength and refine the recommendations for enhancing the performance of 3D-printed provisional restorations in clinical applications.


Assuntos
Resistência à Flexão , Polimetil Metacrilato , Humanos , Resinas Compostas , Resinas Acrílicas , Impressão Tridimensional
13.
BMC Oral Health ; 24(1): 557, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38735940

RESUMO

BACKGROUND: Dental resin-based composites are widely recognized for their aesthetic appeal and adhesive properties, which make them integral to modern restorative dentistry. Despite their advantages, adhesion and biomechanical performance challenges persist, necessitating innovative strategies for improvement. This study addressed the challenges associated with adhesion and biomechanical properties in dental resin-based composites by employing molecular docking and dynamics simulation. METHODS: Molecular docking assesses the binding energies and provides valuable insights into the interactions between monomers, fillers, and coupling agents. This investigation prioritizes SiO2 and TRIS, considering their consistent influence. Molecular dynamics simulations, executed with the Forcite module and COMPASS II force field, extend the analysis to the mechanical properties of dental composite complexes. The simulations encompassed energy minimization, controlled NVT and NPT ensemble simulations, and equilibration stages. Notably, the molecular dynamics simulations spanned a duration of 50 ns. RESULTS: SiO2 and TRIS consistently emerged as influential components, showcasing their versatility in promoting solid interactions. A correlation matrix underscores the significant roles of van der Waals and desolvation energies in determining the overall binding energy. Molecular dynamics simulations provide in-depth insights into the mechanical properties of dental composite complexes. HEMA-SiO2-TRIS excelled in stiffness, BisGMA-SiO2-TRIS prevailed in terms of flexural strength, and EBPADMA-SiO2-TRIS offered a balanced combination of mechanical properties. CONCLUSION: These findings provide valuable insights into optimizing dental composites tailored to diverse clinical requirements. While EBPADMA-SiO2-TRIS demonstrates distinct strengths, this study emphasizes the need for further research. Future investigations should validate the computational findings experimentally and assess the material's response to dynamic environmental factors.


Assuntos
Materiais Biocompatíveis , Resinas Compostas , Simulação de Acoplamento Molecular , Simulação de Dinâmica Molecular , Dióxido de Silício , Resinas Compostas/química , Dióxido de Silício/química , Materiais Biocompatíveis/química , Materiais Dentários/química , Metacrilatos/química , Poliuretanos/química , Ácidos Polimetacrílicos/química , Polietilenoglicóis/química , Resinas Acrílicas/química
14.
BMC Oral Health ; 24(1): 458, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622548

RESUMO

BACKGROUND: Various methods, chemical and physical, disinfect dental impressions. Common chemicals include 1% Sodium Hypochlorite and 2% glutaraldehyde, while UV radiation is a prevalent physical method. Few studies compare their effects on dimensional stability in polyether impressions. This study aims to assess such stability using different disinfection methods. Therefore, this study was planned to evaluate the dimensional stability of polyether impression material using different disinfection methods. METHODS: This in vitro study compared the effects of chemical disinfectants (1% Sodium Hypochlorite and 2% glutaraldehyde) and UV irradiation on the dimensional stability of polyether impression material. Groups A, B, C, and D, each with ten samples (N = 10), were studied. Group A was untreated (control). Group B was treated with 2% glutaraldehyde for 20 min, Group C with 1% Sodium Hypochlorite for 20 min, and Group D with UV rays for 20 min. A pilot milling machine drill was used to make four parallel holes labeled A, B, C, and D in the anterior and premolar regions from right to left. After sequential drilling, four implant analogs were positioned using a surveyor for accuracy. Ten open-tray polyether impressions were made and treated as described in the groups, followed by pouring the corresponding casts. Distortion values for each disinfection method were measured using a coordinate measuring machine capable of recording on the X- and Y-axes. RESULTS: A comprehensive analysis was conducted using the one-way ANOVA test for distinct groups labeled A, B, C, and D, revealing significant differences in the mean distances for X1, X2, X4, X5, and X6 among the groups, with p-values ranging from 0.001 to 0.000. However, no significant differences were observed in X3. Notably, mean distances for the Y variables exhibited substantial differences among the groups, emphasizing parameter variations, with p-values ranging from 0.000 to 0.033. The results compared the four groups using the one-way ANOVA test, revealing statistically significant distance differences for most X and Y variables, except for X3 and Y4. Similarly, post-hoc Tukey's tests provided specific pairwise comparisons, underlining the distinctions between group C and the others in the mean and deviation distances for various variables on both the X- and Y-axes. CONCLUSIONS: This study found that disinfection with 1% sodium hypochlorite or UV rays for 20 min maintained dimensional stability in polyether impressions.


Assuntos
Desinfetantes , Desinfecção , Humanos , Desinfecção/métodos , Glutaral , Hipoclorito de Sódio , Materiais para Moldagem Odontológica , Técnica de Moldagem Odontológica
15.
BMC Med Imaging ; 23(1): 68, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37264339

RESUMO

BACKGROUND: Vertical root fractures (VRFs) sometimes occur in endodontically treated teeth. They have a difficult diagnosis and a dismal result. The objective of this review was to evaluate the diagnostic performance of cone-beam computed tomography (CBCT) for detecting VRFs in teeth that had undergone endodontic treatment. METHODS: Literature was reviewed from Web of Science, PubMed, Cochrane Review, SCOPUS, and Embase databases between 2000 and 2022. The searched keywords included "endodontically treated teeth," "cone-beam computed tomography," "CBCT," "tooth fracture," "vertical root fracture," "VRF," "accuracy," "sensitivity," and "specificity." Only articles in the English language were included. The final analysis included 20 papers that satisfied the eligibility requirements. RESULTS: The overall mean ± SD values (%) for the diagnostic sensitivity and specificity of CBCT for detection of VRFs in endodontically treated teeth in the presence of root-filling materials without an intracanal post were 71.50 ± 22.19 and 75.64 ± 19.41, respectively. The overall mean (SD) value (%) for the sensitivity of CBCT for the detection of VRFs in the presence of root-filling materials and intracanal posts was 72.76 (18.73), while the mean (SD) specificity was 75.44 (18.26). The accuracy of CBCT (mean ± SD) was 78.47 ± 17.19% and 74.02 ± 10.64%, respectively, for teeth without intracanal posts and those with posts. CONCLUSIONS: Further clinical research is needed to validate the optimum efficiency of CBCT as a diagnostic technique for detecting VRFs in teeth that have had endodontic treatment, given the low sensitivity, significant heterogeneity of studies, and lack of in-vivo studies on the subject.


Assuntos
Fraturas dos Dentes , Dente não Vital , Humanos , Dente não Vital/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem , Sensibilidade e Especificidade , Fraturas dos Dentes/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos
16.
J Basic Microbiol ; 63(10): 1059-1072, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37311215

RESUMO

Alzheimer's disease causes memory loss and dementia in older adults through a neurodegenerative mechanism. Despite the pathophysiological clarification of this cognitive disorder, novel molecular and cellular pathways should be identified to determine its exact mechanism. Alzheimer's disease (AD) is pathologically characterized by senile plaques comprising beta-amyloid and neurofibrillary tangles (NFTs) formed by hyperphosphorylated tau as a microtubule-associated protein with a key role in the pathogenesis of AD. Periodontitis through inflammatory pathways is a risk factor for deteriorating cognitive impairment in AD patients. Poor oral hygiene coupled with immunocompromised status in older adults causes periodontal diseases and chronic inflammations through an oral bacterial imbalance. Toxic bacterial products, including bacteria themselves, can reach the central nervous system through the bloodstream and evoke inflammatory responses. The present review was conducted to investigate relationships between AD and periodontitis-involved bacteria as a risk factor.


Assuntos
Doença de Alzheimer , Periodontite , Humanos , Idoso , Doença de Alzheimer/metabolismo , Doença de Alzheimer/patologia , Peptídeos beta-Amiloides/metabolismo , Emaranhados Neurofibrilares/metabolismo , Emaranhados Neurofibrilares/patologia , Periodontite/complicações , Periodontite/metabolismo , Periodontite/patologia , Bactérias/metabolismo
17.
BMC Oral Health ; 23(1): 958, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-38041086

RESUMO

BACKGROUND: Titanium is a commonly used material for dental implants owing to its excellent biocompatibility, strength-to-weight ratio, corrosion resistance, lightweight nature, hypoallergenic properties, and ability to promote tissue adhesion. However, alternative materials, such as titanium alloys (Ti-Al-2 V) and zirconia, are available for dental implant applications. This study discusses the application of Density Functional Theory (DFT) in evaluating dental implant materials' mechanical properties and structural stability, with a specific focus on titanium (Ti) metal. It also discusses the electronic band structures, dynamic stability, and surface properties. Furthermore, it presents the mechanical properties of Ti metal, Ti-Al-2 V alloy, and zirconia, including the stiffness matrices, average properties, and elastic moduli. This research comprehensively studies Ti metal's mechanical properties, structural stability, and surface properties for dental implants. METHODS: We used computational techniques, such as the CASTEP code based on DFT, GGA within the PBE scheme for evaluating electronic exchange-correlation energy, and the BFGS minimization scheme for geometry optimization. The results provide insights into the structural properties of Ti, Ti-Al-2 V, and zirconia, including their crystal structures, space groups, and atomic positions. Elastic properties, Fermi surface analysis, and phonon studies were conducted to evaluate the tensile strength, yield strength, ductility, elastic modulus, Poisson's ratio, hardness, fatigue resistance, and corrosion resistance. RESULTS: The findings were compared with those of Ti-Al-2 V and zirconia to assess the advantages and limitations of each material for dental implant applications. This study demonstrates the application of DFT in evaluating dental implant materials, focusing on titanium, and provides valuable insights into their mechanical properties, structural stability, and surface characteristics. CONCLUSIONS: The findings of this study contribute to the understanding of dental implant material behavior and aid in the design of improved materials with long-term biocompatibility and stability in the oral environment.


Assuntos
Implantes Dentários , Humanos , Titânio/química , Teoria da Densidade Funcional , Materiais Dentários/química , Ligas/química , Teste de Materiais , Propriedades de Superfície
18.
BMC Oral Health ; 23(1): 1013, 2023 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-38110933

RESUMO

BACKGROUND: Ameloblastoma (AM), the benign counterpart of ameloblastic carcinoma, is a benign odontogenic tumor of epithelial origin, naturally aggressive, with unlimited growth potential and a high tendency to relapse if not adequately removed. Patients with AM treated surgically can benefit from dental implant therapy, promoting oral rehabilitation and improving their quality of life. The present study aimed to determine the survival rate of dental implants placed after surgical treatment of patients affected by AM. In addition, there were two secondary objectives: 1) To evaluate which dental implant loading protocols are most frequently used and 2) To determine the type of prosthetic restoration most commonly used in these patients. METHODS: The Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) guidelines were followed during the study. Searches were performed in three databases (PubMed/MEDLINE, Scopus, and Google Scholar) until November 2023. Additionally, the electronic search was enriched by an iterative hand search of journals related to oral pathology and medicine, maxillofacial surgery, and oral prosthodontics and implantology. Only reports and case series in English from January 2003 to date were included. The Joanna Briggs Institute tool (JBI-Case Reports/Case Series) was used for the study quality assessment. RESULTS: The total number of patients and implants studied were 64 and 271, respectively, all with surgically treated AM. The patient's ages ranged from 8 to 79 years, with a mean (SD) age of 37.3 ± 16.4. Fifty-three percent were male and 47% were female. The range of follow-up duration was 1 to 22 years. An implant survival/success rate of 98.1% was reported. In addition, most of them were conventionally loaded (38.3%). Hybrid implant-supported fixed dentures were the most commonly used by prosthodontists (53%). CONCLUSIONS: Oral rehabilitation with dental implants inserted in free flaps for orofacial reconstruction in surgically treated patients with AM can be considered a safe and successful treatment modality.


Assuntos
Ameloblastoma , Implantes Dentários , Tumores Odontogênicos , Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Ameloblastoma/cirurgia , Implantação Dentária Endóssea/métodos , Implantes Dentários/efeitos adversos , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Recidiva Local de Neoplasia/induzido quimicamente , Qualidade de Vida , Resultado do Tratamento
19.
BMC Oral Health ; 23(1): 844, 2023 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-37940890

RESUMO

BACKGROUND: This study aimed to determine the relative positioning accuracy of multiple implants utilizing four distinct types of splinting materials. METHODS: The purpose of this in-vitro study was to compare the precision of four splinting materials in an open tray impression technique in multiple implant situations. Based on the material used for splinting, four groups were made (n = 40)- Group A: Conventional Method, Group B: Prefabricated Pattern Resin Framework, Group C: Prefabricated Metal Framework, Group D: Light Cured Pattern Resin, these groups were compared with the master model. A heat-cured clear acrylic resin and a master model were constructed. A pilot milling machine drill was used to drill four parallel holes in the anterior and premolar regions, which were later labeled as A, B, C, and D positions from right to left. Then, sequential drilling was carried out, and four 3.75­mm diameter and 13-mm long ADIN implant analogs with internal hex were placed in the acrylic model using a surveyor for proper orientation. The impression posts were then manually screwed to the implant analogs using an open tray, and they were secured to the implants using 10 mm flat head guide pins with a 15 N.cm torque. 10 Open tray polyether impressions were made, and casts were poured. Each splinting method's distortion values were measured using a coordinate measuring machine capable of recordings in the X-, Y-, and Z-axes. Comparison of mean distances for X1, X2, and X3 was made using the Kruskal-Wallis test, and Pairwise comparison was done using Post Hoc Tukey's Test. RESULTS: The differences between the groups were significant when assessing the distances X1, X2, and X3 (p < 0.05). The comparison of deviations between the groups revealed a statistically significant difference (p < 0.05) for the deviation distance X3 but not for the deviation distances X1 and X2. For distance Y1, the difference between the groups was statistically significant (p0.05), but it was not significant for distances Y2 and Y3. A statistically significant difference was seen in the comparison between the groups (p < 0.05) for the deviation distances Y1, Y2, and Y3. The results were statistically significant for the distance Z1 comparisons, namely, control vs. Group A (p = 0.012), control vs. Group B (p = 0.049), control vs. Group C (p = 0.048), and control vs. Group D (p = 0.021), and for distance Z3 comparison for control vs. Group A (p = 0.033). The results were statistically insignificant for the distance Z2 comparisons (p > 0.05). CONCLUSIONS: All splinting materials produced master casts with measurements in close proximity to the reference model. However, prefabricated pattern resin bars splinting showed the highest accuracy among the studied techniques. The most recent splinting techniques using prefabricated metal framework and light-cure pattern resin showed similar accuracy.


Assuntos
Implantes Dentários , Humanos , Técnica de Moldagem Odontológica , Materiais para Moldagem Odontológica , Modelos Dentários , Resinas Acrílicas
20.
J Prosthodont ; 2023 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-37675589

RESUMO

PURPOSE: The purpose of this in vitro investigation was to assess how implant depth could affect the three-dimensional positional accuracy of digital impressions made from angulated implants. MATERIALS AND METHODS: Four modified maxillary models were printed and divided into four study groups. In each model, two angulated implant analogs were placed at the sites of the first premolar and first molar at four different depths of 1 (G1), 2 (G2), 3 (G3), and 4 (G4) mm from the models' edentate area. Scan bodies were connected to the analogs, and one operator made 10 full-arch scans for each master model using an intraoral scanner. Afterward, the marginal gingival part of all models was removed, and digital scans were performed for each model using a laboratory scanner to achieve a reference STL file as the control group. One-way ANOVA and Leven's tests were used to measure and compare the 3D distance deviations across research groups after the superimposing test and control scans. RESULTS: A significant difference between research groups was revealed by trueness and precision analysis (p < 0.001). The trueness and precision results obtained for G1 and G4 were significantly better than those for G2 and G3 (p < 0.05). CONCLUSION: This study demonstrated that implant depth could affect the digital implant impressions' 3D positional accuracy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA