Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38976634

RESUMO

OBJECTIVES: This study aimed to assess the accuracy of ultra-low dose (ULD) cone-beam computed tomography (CBCT) for detection of proximal caries. METHODS: This in vitro study evaluated 104 molar and premolar teeth. The teeth were mounted in dry skulls and underwent CBCT with four protocols of high-resolution (HR), normal (NORM), ULD-HR, and ULD-NORM; 78 CBCT images were scored by three observers for presence and penetration depth of caries twice with a 2-week interval using a 5-point Likert scale. The teeth were then sectioned and observed under a stereomicroscope (gold standard). The four protocols were compared with each other and with the gold standard. The receiver operating characteristic (ROC) curve was drawn, and the area under the curve (AUC) was calculated and compared by the Chi-square test (alpha = 0.05). RESULTS: The interobserver agreement ranged from 0.5233 to 0.6034 for ULD-NORM, 0.5380 to 0.6279 for NORM, 0.5856 to 0.6300 for ULD-HR, and 0.6614 to 0.7707 for HR images. The intra-observer agreement ranged from 0.6027 to 0.8812 for ULD-HR, 0.7083 to 0.7556 for HR, 0.6076 to 0.9452 for ULD-NORM, and 0.7012 to 0.9221 for NORM images. Comparison of AUC revealed no significant difference between NORM and ULD-NORM (P > 0.05), or HR and ULD-HR (P > 0.05). The highest AUC belonged to HR (0.8529) and the lowest to NORM (0.7774). CONCLUSIONS: Considering the significant reduction in radiation dose in ULD CBCT and its acceptable diagnostic accuracy for detection of proximal caries, this protocol may be used for detection of proximal carious lesions and assessment of their depth.

2.
Turk J Orthod ; 37(1): 56-62, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38556954

RESUMO

Objective: This study aimed to evaluate the accuracy of dental calcification stages in predicting the peak pubertal stage. Methods: This retrospective study was conducted on panoramic and lateral cephalometric images of 406 female patients aged 9-14 years. The skeletal maturity and calcification stages of the mandibular canines, first premolars, second premolars, and second molars were determined using the Hassel-Farman and Demirjian (DI) methods, respectively. The prediction accuracy of the peak pubertal stage with the studied teeth was assessed using a receiver operating characteristic curve and the area under the curve (AUC). The DI stage of H was designated as the reference level, and Bayesian logistic regression analysis was used to assess the coinciding chance of each DI stage and peak pubertal stage. Results: The AUC range of studied teeth was 0.84-0.92 in predicting peak pubertal stage (all p<0.001). In the canines and first premolars, the coinciding chance of peak pubertal stage and stage H was significantly higher than that in other stages [p<0.05, odds ratio (OR) ≤0.14]. In the second premolars and second molars, the chance of peak pubertal stage coinciding with stages H and G did not significantly differ (p>0.05); however, the chance of stage G coinciding with peak pubertal stage in the second molars was higher than in stage H (OR=4.59). Conclusion: Stage H in all studied teeth and stage G in the second premolars and second molars predict peak pubertal stage with high accuracy. Considering that stage H is the end of tooth calcification stages and the accuracy of predicting stage G of second molar teeth is higher than the above stage, estimating the peak pubertal stage is recommended by the second case.

3.
Int J Dent ; 2021: 5643668, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34737775

RESUMO

INTRODUCTION: Although primary teeth have a determinative role in development of normal occlusion, few studies about anomalies related to deciduous dentition have been conducted so far. Regarding recent improvements in common knowledge and the importance of maintaining primary teeth until eruption of succedaneous teeth, identifying the morphology of primary teeth and probable variations is of great importance to achieve optimal therapeutic outcome. This study aims to determine the prevalence of three-rooted mandibular primary molars in a population of northwestern Iran. MATERIALS AND METHODS: In this descriptive cross-sectional study, periapical radiographs of patients attending private oral and maxillofacial radiology offices in the northwestern region of Iran from 2017 to 2019 were retrospectively reviewed. A total of 300 cases in the 3-10-year age range having bilateral periapical radiographs from mandibular primary molars were screened. First and second primary molars were observed meticulously. Gender, side of the mandible (right or left), symmetry, overall prevalence, and prevalence considering the type of molar (D or E) were recorded and analyzed. RESULTS: Overall prevalence of three-rooted mandibular primary molars was 9.33% ( 28/300), 92.9% of which were unilateral. The prevalence of teeth showing supernumerary roots among all teeth examined was 2.5% (30/1200). Considering symmetry and gender, the occurrence of these three-rooted primary molars did not differ significantly (respectively, p=0.832 and p=0.541). However, there was a significant relationship between the occurrence of supernumerary roots and left side for three-rooted first molars and right side for three-rooted second molars (p=0.021). CONCLUSION: Obtained data show that three-rooted mandibular primary molars in children of northwest region of Iran have a prevalence of approximately 10 % which urges some specific considerations in exodontic and endodontic procedures.

4.
RSC Adv ; 10(26): 15430-15460, 2020 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-35495474

RESUMO

Research and development in the applied sciences at the atomic or molecular level is the order of the day under the domain of nanotechnology or nano-science with enormous influence on nearly all areas of human health and activities comprising diverse medical fields such as pharmacological studies, clinical diagnoses, and supplementary immune system. The field of nano-dentistry has emerged due to the assorted dental applications of nano-technology. This review provides a brief introduction to the general nanotechnology field and a comprehensive overview of the synthesis features and dental uses of nano-materials including current innovations and future expectations with general comments on the latest advancements in the mechanisms and the most significant toxicological dimensions.

5.
J Endod ; 44(5): 738-743, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29550011

RESUMO

INTRODUCTION: The present study aimed to anatomically assess mandibular posterior teeth using cone-beam computed tomographic (CBCT) imaging for endodontic surgery. METHODS: A total of 170 CBCT scans were evaluated for anatomic variations of mandibular posterior teeth. All the scans were obtained using a Planmeca Promax CBCT unit (Planmeca, Helsinki, Finland) with exposure settings of 90 kVp, 12 mA, 12 seconds, and 0.3-mm resolution. All CBCT images were reconstructed by Romexis Viewer 3.8.2. software (Planmeca) on a 16-inch LCD monitor (22MP47HQ; LG, Seoul, South Korea), and axial, coronal and sagittal views were evaluated. RESULTS: The thickest buccal cortical plate was observed over the distal root of second molars (12.30 mm) among the molar teeth and over the second premolar root (5.41 mm) among the premolar teeth. The thinnest buccal cortical plate was observed over both the first and second premolar roots (0.42 mm) and over the mesial root of the first molar (0.62 mm) tooth. A 20.38-mm section was removed for surgical access during buccal resection of the distal root of the left second molar, and the closest distance from the apex to the inferior alveolar canal was 0 mm. CONCLUSIONS: Adequate knowledge of the anatomic dimensions of teeth and their surrounding structures is imperative for endodontic surgery. Information concerning the root thickness of mandibular posterior teeth at the site of root resection (apical 3 mm), buccal cortical plate thickness, and the distance from the apex of each tooth to the inferior alveolar canal and mental foramen can guide the surgeon before and during surgery.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Dente Molar/diagnóstico por imagem , Radiografia Dentária , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Mandíbula/diagnóstico por imagem , Pessoa de Meia-Idade , Dente Molar/anatomia & histologia , Procedimentos Cirúrgicos Bucais , Ápice Dentário/anatomia & histologia , Ápice Dentário/diagnóstico por imagem , Raiz Dentária/anatomia & histologia , Raiz Dentária/diagnóstico por imagem , Adulto Jovem
6.
J Dent (Tehran) ; 12(11): 797-806, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27507990

RESUMO

OBJECTIVES: The optimal goal of radiography is to provide high-quality diagnostic images with the least patient radiation dose. The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT) and intraoral photostimulable phosphor plate (PSP) digital and film-based conventional radiography for detection of artificial cancellous bone defects. MATERIALS AND METHODS: Five dry human mandibles were used in this study. The mandibles were placed inside a water bath made of plexiglass plates; then PSP and CBCT scans were obtained. The mandibles were cut by a coping saw in buccolingual dimension and oval defects measuring 6.1×6.1 mm, 3×6.1 mm and 4×4 mm were created by a milling machine in the spongy bone. After fixing the two parts together (buccal and lingual), radiographs were repeated. Presence or absence of defects on images was evaluated and recorded by the two observers. Using SPSS 16, compatibility level, sensitivity, specificity and receiver operating curve (ROC) analysis were determined for each observer. RESULTS: The intraobserver agreement in all three imaging modalities was low to moderate (kappa≤0.613). The inter-observer agreement in all the three imaging modalities was moderate (kappa=0.406). The area under the curve (AUC) of the imaging modalities in each observation was not significantly different. The area under the curve based on defect size for the two observers was not significantly different either. CONCLUSION: Defects confined to spongy bone can be identified on film and PSP radiographs and CBCT scans. However, interpretation of PSP images and CBCT scans needs greater expertise and skills.

7.
J Oral Sci ; 52(4): 593-7, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21206162

RESUMO

To assess the diagnostic accuracy of cone beam computed tomography (CBCT) in comparison with conventional radiography for vertical root fractures, 50 of 100 teeth were subjected to vertical root fracture (VRF) and then placed in dry mandibles. 3D scans were obtained for all teeth, and conventional radiographs were used as control images. All the images were assessed by 6 observers, who determined the presence of root fractures by using a 5-point confidence rating scale. The mean area under the curve (Az) for CBCT was 0.91, and that for conventional radiography was 0.64. The difference between the modalities was statistically significant (P = 0.003). On the basis of interclass coefficient, inter-observer agreement for CBCT was 0/750, and that for conventional radiography was 0/637. Thus CBCT was shown to be significantly better than conventional periapical radiography for diagnosis of vertical root fractures in vitro.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Radiografia Dentária/métodos , Fraturas dos Dentes/diagnóstico por imagem , Raiz Dentária/lesões , Cadáver , Humanos , Mandíbula , Curva ROC , Raiz Dentária/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA