Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
J Artif Organs ; 25(2): 140-147, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34708284

RESUMO

The impact of sports on long-term wear of highly cross-linked polyethylene (XLPE) after total hip arthroplasty (THA) is not fully understood. We investigated (1) the wear performance of the first-generation XLPE, and (2) whether sports participation influences the steady wear rate of XLPE. The femoral head penetration into the cup was measured digitally on radiographs of hips undergoing THA with XLPE. We retrospectively reviewed data that included age, gender, body mass index, follow-up period, preoperative diagnosis, types of XLPE, ball diameter, head material, inclination of the cup, physical function score, and sports participation. Statistical analyses were applied to determine whether sports affect the wear of XLPE and which factors were associated with the steady wear rate. Creep and steady wear rate were found to be 0.18 mm and 0.005 mm/year, respectively. Sports participation, regardless of impact, provided no significant difference in the steady wear rate. Multiple regression analysis demonstrated that sports did not increase the steady wear rate. Our findings showed excellent wear performance of the first-generation XLPE at a minimum of ten years after THA, without significant effect of sports participation on the liner wear.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Seguimentos , Humanos , Polietileno , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos
2.
J Orthop Sci ; 23(4): 665-670, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29657105

RESUMO

BACKGROUNDS: The purpose of this study was to quantify the initial stability of a highly porous titanium cup using an acetabular bone defect model. METHODS: The maximum torque of a highly porous titanium cup, with a pore size of 640 µm and porosity of 60%, was measured using rotational and lever-out torque testing and compared to that of a titanium-sprayed cup. The bone models were prepared using a polyurethane foam block and had three levels of bone coverage: 100, 70, and 50%. RESULTS: The highly porous titanium cup demonstrated significantly higher maximum torque than the titanium-sprayed cups in the three levels of bone defects. On rotational torque testing, it was found to be 1.5, 1.3, and 1.3 times stronger than the titanium-sprayed cups with 100, 70 and 50% bone coverage, respectively. Furthermore, it was found to be 2.2, 2.3, and 1.5 times stronger on lever-out testing than the titanium-sprayed cup. No breakage in the porous layers was noted during the testing. CONCLUSION: This study provides additional evidence of the initial stability of highly porous titanium cup, even in the presence of acetabular bone defects.


Assuntos
Acetábulo , Prótese de Quadril , Resistência à Tração , Titânio , Fenômenos Biomecânicos , Humanos , Teste de Materiais , Modelos Anatômicos , Poliuretanos , Desenho de Prótese , Propriedades de Superfície
3.
J Mater Sci Mater Med ; 28(6): 85, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28456893

RESUMO

This study aimed to evaluate in vivo behavior of a carbonate apatite (CO3Ap) block fabricated by compositional transformation via a dissolution-precipitation reaction using a calcium hydrogen phosphate dihydrate [DCPD: CaHPO4·2H2O] block as a precursor. These blocks were used to reconstruct defects in the femur and tibia of rabbits, using sintered dense hydroxyapatite (HAp) blocks as the control. Both the CO3Ap and HAp blocks showed excellent tissue response and good osteoconductivity. HAp block maintained its structure even after 24 weeks of implantation, so no bone replacement of the implant was observed throughout the post-implantation period in either femoral or tibial bone defects. In contrast, CO3Ap was resorbed with increasing time after implantation and replaced with new bone. The CO3Ap block was resorbed approximately twice as fast at the metaphysis of the proximal tibia than at the epiphysis of the distal femur. The CO3Ap block was resorbed at an approximately linear change over time, with complete resorption was estimated by extrapolation of data at approximately 1-1.5 years. Hence, the CO3Ap block fabricated in this study has potential value as an ideal artificial bone substitute because of its resorption and subsequent replacement by bone.


Assuntos
Apatitas/química , Substitutos Ósseos , Fosfatos de Cálcio/química , Animais , Durapatita , Epífises , Fêmur , Próteses e Implantes , Coelhos , Tíbia
4.
J Arthroplasty ; 31(6): 1228-1232, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26730449

RESUMO

BACKGROUND: Hydroxyapatite (HA) has been applied to joint prostheses as a bioactive coating to prolong their durability. However, HA benefits for cup survival in total hip arthroplasty (THA) remain controversial. In this study, we compared the survival of cups with and without HA coating during a minimum follow-up of 18 years. METHODS: In total, 183 THA cases in 163 patients were analyzed, including 73 cups with HA coating (HA(+) group) and 110 without HA coating (HA(-) group); otherwise, the cups had identical titanium-sprayed rough surfaces and were fixed with screws. In both groups, the same conventional polyethylene liners were applied. Zirconia and alumina ceramic heads were used in the HA(+) and HA(-) groups, respectively. We retrospectively analyzed cup survival based on cup revision for any reason or aseptic loosening as end points. RESULTS: In total, 7 and 8 revisions were performed in the HA(-) and HA(+) groups with survival rates of 86.3% and 90.1%, respectively. Among them, 3 cups in the HA(-) group and 1 cup in the HA(+) group were revised for aseptic loosening in 20 years (survival rates 94.1% and 98.7%, respectively). No significant difference was detected in cup survival rates between the groups based on both end points. There were no stem revisions during the observation period. CONCLUSION: The results suggested that HA coating did not have either beneficial or adverse effects on the long-term cup survival in primary cementless THA.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Materiais Revestidos Biocompatíveis/uso terapêutico , Durapatita/química , Prótese de Quadril/efeitos adversos , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Polietileno , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Taxa de Sobrevida , Fatores de Tempo , Titânio , Resultado do Tratamento
5.
J Orthop Sci ; 20(5): 881-7, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26209279

RESUMO

BACKGROUND: Fracture of the femoral stem in total hip arthroplasty (THA) is a rare complication. We have encountered 2 cases of neck fractures of the femoral stem occurring 9 and 12 years after THA. Morphological and biomechanical analysis were performed to investigate the mechanism of these fractures. METHOD: A titanium alloy femoral stem having a slot with sharp corners (R = 0.2 mm) at the neck had been implanted in both cases. Fracture surfaces were examined by use of scanning electron microscopy (SEM). Stress concentration was simulated by using a finite element method (FEM) to compare slots with sharp (R = 0.2 mm) and smooth (R = 2 mm) corners. RESULTS: Study of the retrieved stems revealed that neck fractures had occurred at the distal end of the slot in both cases. SEM revealed numerous fine fissures extending from the anterolateral edge, striations on the middle of the fracture surface, and dimples on the posteromedial surface, suggesting that the fractures had occurred from the anterolateral aspect toward the posteromedial aspect because of metallic fatigue. FEM analysis showed that mechanical stress was concentrated at the distal and anterolateral corners of the slot. Under 3500-N loading force, the stress at the sharp corner was 556 MPa, which was approximately twofold that at the smooth corner and exceeded the fatigue strength of titanium alloy. CONCLUSION: These findings showed that the sharp corner of slot increased stress concentrations at the anterolateral aspect and led to the neck fractures.


Assuntos
Artroplastia de Quadril/efeitos adversos , Fraturas do Colo Femoral/fisiopatologia , Ligas , Fenômenos Biomecânicos , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/cirurgia , Análise de Elementos Finitos , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Radiografia , Reoperação , Estresse Mecânico
6.
J Arthroplasty ; 28(9): 1648-53, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23602234

RESUMO

To examine the accuracy of intraoperative estimation of stem anteversion in total hip arthroplasty (THA), we compared the intraoperatively estimated stem anteversion (estimated prosthetic anteversion) to stem anteversion measured by postoperative computed tomography (true anteversion) in 73 hips in 73 patients. Estimated prosthetic anteversion was significantly greater than true anteversion by 5.8°, and the mean absolute value of surgeon error was 7.3° ranging from 11° underestimation to 25° overestimation. Surgeons tended to overestimate when the true anteversion was smaller. A multivariate analysis showed that advanced knee osteoarthritis significantly increased surgeon error. These results indicated that estimated prosthetic anteversion was generally larger than true anteversion and that the grade of knee osteoarthritis affected the degree of surgeon error.


Assuntos
Artroplastia de Quadril/métodos , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Artropatias/cirurgia , Erros Médicos , Idoso , Cimentação , Feminino , Articulação do Quadril/cirurgia , Humanos , Cuidados Intraoperatórios , Artropatias/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia Computadorizada por Raios X
7.
J Orthop Sci ; 18(6): 962-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23963589

RESUMO

PURPOSE: The purpose of this study was to report results at a minimum of 10 years for hydroxyapatite (HA) coating on the titanium arc-sprayed cementless total hip arthroplasty (THA) and to evaluate the impact of cross-linked polyethylene (XLPE) on implant longevity. METHODS: A total of 131 consecutive primary THAs in 123 patients using an AMS acetabular cup and a PerFix HA stem were retrospectively reviewed. Conventional PE was used for 62 hips (CPE group) and cross-linked PE for 69 hips (XLPE group), with mean follow-up periods of 13 and 11.5 years, respectively. These patients were reviewed using the Japanese Orthopaedic Association (JOA) Hip Score and evaluated in terms of PE wear, osteolysis, and implant survival. RESULTS: The JOA score improved from 42.6 to 83.9 points at the final follow-up. The mean wear rate of 0.12 mm/year in the CPE group was significantly greater than that of XLPE at 0.007 mm/year. In the CPE group, ten (16.1 %) and two (3.2 %) hips, respectively, underwent PE exchange due to severe wear and acetabular revision due to loosening associated with osteolysis. Three patients had revision in the XLPE group: one cup for aseptic loosening, one PE for recurrent dislocation, and one stem for neck fracture. No evident osteolysis was seen in the XLPE group. Kaplan-Meier survivorship with any revision as the end point shows that the 12-year survival rate was 97.7 % for cups, 93.8 % for PE liners, and 99.2 % for stems. Multivariate analysis revealed that the use of XLPE significantly reduced the risk of revision, with the odds ratio (OR) of 4.3. CONCLUSIONS: AMS and PerFix HA components in this series show excellent implant fixation; however, high rates of PE wear and subsequent osteolysis were limiting factors in long-term success. Low wear rates with XLPE suggest improved implant longevity.


Assuntos
Artroplastia de Quadril/métodos , Durapatita , Prótese de Quadril , Polietilenos , Retenção da Prótese/métodos , Idoso , Artroplastia de Quadril/efeitos adversos , Cimentos Ósseos , Materiais Revestidos Biocompatíveis , Estudos de Coortes , Análise de Falha de Equipamento , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Desenho de Prótese/métodos , Falha de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Tempo , Titânio , Resultado do Tratamento
8.
Mod Rheumatol ; 23(1): 112-8, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22395477

RESUMO

OBJECTIVES: Porous tantalum is a biomaterial newly applied for artificial joints. We present here 5-years follow-up report of a multicenter clinical trial of total hip arthroplasties (THA) with porous tantalum modular acetabular component (modular PTC). METHODS: Study participants received 82 hips in 79 cases, with 61.2 months follow-up on average. Age at operation was 60.9 years. Clinical results were evaluated using Merle d'Aubigne Postel score. Presence of implant loosening, periacetabular radiolucency, osteolysis, and gap filling were examined for radiographic results. RESULTS: Merle d'Aubigne Postel score improved from 10.0 to 16.4 points. All PTC were radiographically stable, with no evidence of progressive radiolucencies. Average polyethylene wear rate was 0.004 mm/year, with no periacetabular osteolysis. Fifteen hips (18.3%) showed a gap >1 mm; however, all showed bone filling within 12 months. PTC with oversized reaming was significantly less likely to have a gap. No implant failure was noted related to modularity. Resulting survival rate of modular PTC was 100% at 5 years. CONCLUSIONS: Modular PTC showed excellent results at 5-years of follow-up. Some hips showed periacetabular gaps, which were filled with bone within 1 year. Further follow-up was needed to determine long-term efficacy.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/instrumentação , Prótese de Quadril , Tantálio , Acetábulo/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Artrite Reumatoide/cirurgia , Cimentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osseointegração , Osteoartrite do Quadril/cirurgia , Osteonecrose/cirurgia , Porosidade , Desenho de Prótese , Falha de Prótese/etiologia , Radiografia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Taxa de Sobrevida , Tantálio/efeitos adversos , Resultado do Tratamento , Adulto Jovem
9.
Sci Rep ; 12(1): 15580, 2022 09 16.
Artigo em Inglês | MEDLINE | ID: mdl-36114355

RESUMO

In crush syndrome, massive muscle breakdown resulting from ischemia-reperfusion muscle injury can be a life-threatening condition that requires urgent treatment. Blood reperfusion into the ischemic muscle triggers an immediate inflammatory response, and neutrophils are the first to infiltrate and exacerbate the muscle damage. Since free zinc ion play a critical role in the immune system and the function of neutrophils is impaired by zinc depletion, we hypothesized that the administration of a zinc chelator would be effective for suppressing the inflammatory reaction at the site of ischemia-reperfusion injury and for improving of the pathology of crush syndrome. A crush syndrome model was created by using a rubber tourniquet to compress the bilateral hind limbs of mice at 8 weeks. A zinc chelator N,N,N',N'-tetrakis-(2-pyridylmethyl)-ethylenediamine (TPEN) was administered immediately after reperfusion in order to assess the anti-inflammatory effect of the chelator for neutrophils. Histopathological evaluation showed significantly less muscle breakdown and fewer neutrophil infiltration in TPEN administration group compared with control group. In addition, the expression levels of inflammatory cytokine and chemokine such as IL-6, TNFα, CXCL1, CXCL2, CXCR2, CCL2 in ischemia-reperfusion injured muscle were significantly suppressed with TPEN treatment. Less dilatation of renal tubules in histological evaluation in renal tissue and significantly better survival rate were demonstrated in TPEN treatment for ischemia-reperfusion injury in crush syndrome. The findings of our study suggest that zinc chelators contributed to the resolution of exacerbation of the inflammatory response and attenuation of muscle breakdown in the acute phase after crush syndrome. In addition, our strategy of attenuation of the acute inflammatory reaction by zinc chelators may provide a promising therapeutic strategy not only for crush syndrome, but also for other diseases driven by inflammatory reactions.


Assuntos
Quelantes , Síndrome de Esmagamento , Infiltração de Neutrófilos , Traumatismo por Reperfusão , Animais , Anti-Inflamatórios/farmacologia , Anti-Inflamatórios/uso terapêutico , Quelantes/uso terapêutico , Quimiocinas , Síndrome de Esmagamento/tratamento farmacológico , Citocinas , Etilenodiaminas , Inflamação/tratamento farmacológico , Interleucina-6/uso terapêutico , Isquemia/tratamento farmacológico , Camundongos , Músculos/patologia , Infiltração de Neutrófilos/efeitos dos fármacos , Reperfusão , Traumatismo por Reperfusão/complicações , Traumatismo por Reperfusão/tratamento farmacológico , Traumatismo por Reperfusão/patologia , Borracha , Fator de Necrose Tumoral alfa/uso terapêutico , Zinco/farmacologia
10.
J Orthop Surg Res ; 16(1): 140, 2021 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-33596927

RESUMO

BACKGROUND: To clarify contemporary indications for first-time revision surgery after primary cementless total hip arthroplasty (THA) for addressing potential issues with cementless THA. METHODS: Data for 101 consecutive hips in 94 patients who underwent primary cementless THA at our institution and subsequently underwent first-time revision surgery were retrospectively reviewed. Baseline characteristics, indications for first-time revision surgery, and time from the primary THA to first-time revision surgery were evaluated. RESULTS: The overall mean time to first-time revision surgery was 10.3 years (range, 0-33 years). The indications for first-time revision surgery were polyethylene wear and osteolysis in 33 hips, aseptic loosening in 25 hips, infection in 17 hips, periprosthetic fracture in 13 hips, instability in 8 hips, and component failure (liner dissociation or stem fracture) in 5 hips. Thirty-seven hips (37%) had undergone first-time revision surgery within 5 years of primary THA, of which the most common indications were infection and periprosthetic fracture. CONCLUSION: The current results suggested that reducing the number of early failures seems to be essential form improving THA outcomes.


Assuntos
Artroplastia de Quadril/métodos , Cimentos Ósseos , Reoperação , Falha de Tratamento , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise , Fraturas Periprotéticas , Polietileno , Desenho de Prótese , Falha de Prótese , Infecções Relacionadas à Prótese , Estudos Retrospectivos , Fatores de Tempo
11.
JBJS Case Connect ; 11(1)2021 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-33625128

RESUMO

CASE: A 45-year-old woman with severe back pain underwent percutaneous curettage and balloon kyphoplasty (BKP) of a lesion believed to be aneurysmal bone cyst. Three months after BKP, local recurrence was observed, and the histological diagnosis was revised to malignant tumor. Thus, we performed a total en bloc spondylectomy, and the L3 vertebral body was resected. She was reconstructed by titanium expandable cage, rod, and pedicle screws. We observed viable tumor cells and foreign body reaction adjacent to the polymethylmethacrylate cement, carrying no bone necrosis. CONCLUSIONS: The long-term durability and safety of BKP for metastatic spine disease should be further clarified.


Assuntos
Cifoplastia , Dor nas Costas , Cimentos Ósseos , Feminino , Humanos , Cifoplastia/efeitos adversos , Pessoa de Meia-Idade , Resultado do Tratamento , Corpo Vertebral
12.
Sci Rep ; 8(1): 16887, 2018 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-30442906

RESUMO

This study was aimed to investigate the osseointegration ability of poly(ether ether ketone) (PEEK) implants with modified surface roughness and/or surface chemistry. The roughened surface was prepared by a sandblast method, and the phosphate groups on the substrates were modified by a two-step chemical reaction. The in vitro osteogenic activity of rat mesenchymal stem cells (MSCs) on the developed substrates was assessed by measuring cell proliferation, alkaline phosphatase activity, osteocalcin expression, and bone-like nodule formation. Surface roughening alone did not improve MSC responses. However, phosphorylation of smooth substrates increased cell responses, which were further elevated in combination with surface roughening. Moreover, in a rabbit tibia implantation model, this combined surface modification significantly enhanced the bone-to-implant contact ratio and corresponding bone-to-implant bonding strength at 4 and 8 weeks post-implantation, whereas modification of surface roughness or surface chemistry alone did not. This study demonstrates that combination of surface roughness and chemical modification on PEEK significantly promotes cell responses and osseointegration ability in a synergistic manner both in vitro and in vivo. Therefore, this is a simple and promising technique for improving the poor osseointegration ability of PEEK-based orthopedic/dental implants.


Assuntos
Cetonas/química , Cetonas/farmacologia , Osseointegração/efeitos dos fármacos , Polietilenoglicóis/química , Polietilenoglicóis/farmacologia , Tíbia/fisiologia , Animais , Benzofenonas , Implantes Experimentais , Masculino , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Células-Tronco Mesenquimais/metabolismo , Fosforilação/efeitos dos fármacos , Espectroscopia Fotoeletrônica , Polímeros , Coelhos , Ratos Wistar , Propriedades de Superfície , Tíbia/efeitos dos fármacos
13.
J Orthop Res ; 35(11): 2465-2475, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28303595

RESUMO

Statins are cholesterol-lowering drugs that inhibit 3-hydroxy-3-methylglutaryl-coenzyme A (HMG-CoA) reductase, a rate-limiting enzyme of the mevalonate pathway. The anti-inflammatory effect of statins has been reported in recent years. The present study investigated therapeutic effects of the local administration of statin in osteoarthritis (OA). We assessed clinically used statins and selected fluvastatin for further experimentation, as it showed potent anabolic and anti-catabolic effects on human OA chondrocytes. To achieve controlled intra-articular administration of statin, we developed an intra-articular injectable statin using poly(lactic-co-glycolic acid) (PLGA) as a drug delivery system (DDS). The release profile of the statin was evaluated in vitro. Finally, therapeutic effects of fluvastatin-loaded PLGA microspheres (FLU-PLGA) were tested in a rabbit OA model. Rabbit knees were divided into four subgroups: group 1-A, PLGA-treated group; group 1-B, PLGA contralateral saline control group; group 2-A, FLU-PLGA-treated group; and group 2-B, FLU-PLGA contralateral saline control group. Histological analysis 5 weeks after intra-articular injection revealed that OARSI scores were lower in group 2-A. No significant differences in OARSI scores were observed between groups 1-A, 1-B, and 2-B. This study indicates that a single intra-articular injection of fluvastatin-loaded PLGA microspheres could be a novel therapeutic approach for treating patients with OA. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2465-2475, 2017.


Assuntos
Anticolesterolemiantes/administração & dosagem , Artrite Experimental/tratamento farmacológico , Cartilagem Articular/efeitos dos fármacos , Ácidos Graxos Monoinsaturados/administração & dosagem , Indóis/administração & dosagem , Osteoartrite/tratamento farmacológico , Animais , Condrócitos/efeitos dos fármacos , Avaliação Pré-Clínica de Medicamentos , Feminino , Fluvastatina , Humanos , Injeções Intra-Articulares , Ácido Láctico , Microesferas , Ácido Poliglicólico , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Cultura Primária de Células , Coelhos
14.
Hum Genome Var ; 3: 16007, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27274858

RESUMO

The purpose of this study was to describe a family with spondyloepiphyseal dysplasia caused by a novel type II collagen gene (COL2A1) mutation and the family's phenotypic diversity. Clinical and radiographic examinations of skeletal dysplasia were conducted on seven affected family members across two generations. The entire coding region of COL2A1, including the flanking intron regions, was analyzed with PCR and direct sequencing. The stature of the subjects ranged from extremely short to within normal height range. Hip deformity and advanced osteoarthritis were noted in all the subjects, ranging from severe coxa plana to mild acetabular dysplasia. Atlantoaxial subluxation combined with a hypoplastic odontoid process was found in three of the subjects. Various degrees of platyspondyly were confirmed in all subjects. Genetically, a novel COL2A1 mutation (c.1349G>C, p.Gly450Ala) was identified in all the affected family members; however, it was not present in the one unaffected family member tested. We described a family with spondyloepiphyseal dysplasia and a novel COL2A1 mutation (c.1349G>C, p.Gly450Ala). Phenotypes were diverse even among individuals with the same mutation and within the same family.

15.
Mater Sci Eng C Mater Biol Appl ; 59: 1047-1052, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26652463

RESUMO

The present study examined the bone bonding strength of diamond-structured porous titanium-alloy (Porous-Ti-alloy) manufactured using the electron beam-melting technique in comparison with fiber mesh-coated or rough-surfaced implants. Cylindrical implants with four different pore sizes (500, 640, 800, and 1000µm) of Porous-Ti-alloy, titanium fiber mesh (FM), and surfaces roughened by titanium arc spray (Ti-spray) were implanted into the distal femur of rabbits. Bone bonding strength and histological bone ingrowth were evaluated at 4 and 12weeks after implantation. The bone bonding strength of Porous-Ti-alloy implants (640µm pore size) increased over time from 541.4N at 4weeks to 704.6N at 12weeks and was comparable to that of FM and Ti-spray implants at both weeks. No breakage of the porous structure after mechanical testing was found with Porous-Ti-alloy implants. Histological bone ingrowth that increased with implantation time occurred along the inner structure of Porous-Ti-alloy implants. There was no difference in bone ingrowth in Porous-Ti-alloy implants with pore sizes among 500, 640, and 800µm; however, less bone ingrowth was observed with the 1000µm pore size. These results indicated Porous-Ti-alloy implants with pore size under 800µm provided biologically active and mechanically stable surface for implant fixation to bone, and had potential advantages for weight bearing orthopedic implants such as acetabular cups.


Assuntos
Diamante/química , Fêmur/química , Teste de Materiais/métodos , Titânio/química , Ligas , Animais , Porosidade , Desenho de Prótese , Coelhos
16.
J Mech Behav Biomed Mater ; 59: 99-107, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26751705

RESUMO

No previous studies comparing the clinical wear rates of the two different kinds of cross-linked ultra-high-molecular-weight polyethylene (XLPE), annealed and remelted, are available. We compared the creep and steady wear rates of 36 matched pairs (72 hips in total) adjusting for baseline characteristics with propensity score matching techniques. Zirconia femoral heads with 26-mm diameter were used in all cases. The femoral-head cup penetration was measured digitally on radiographs. Significantly greater creep (p=0.006) was detected in the remelted (0.234mm) than annealed (0.159mm) XLPE. However, no significant difference (p=0.19) was found between the steady wear rates (0.003 and 0.008mm/year, respectively) of the annealed and remelted XLPE. Multiple regression analyses showed that remelted XLPE is significant independent variable (p<0.001) that is positively associated with creep. However, the patient age and body weight, cup size, the liner thickness, cup inclination, follow-up periods, and postoperative Merle d'Aubigné hip score had no significant effects (p>0.05) on the steady wear rates. No patients exhibited above the osteolysis threshold of 0.1mm/year, progressive radiolucencies, osteolysis, or polyethylene fracture. This propensity-matched cohort study document no significant difference in wear resistant performances of annealed and remelted XLPE over an average period of 10 years.


Assuntos
Prótese de Quadril , Polietileno/análise , Falha de Prótese , Artroplastia de Quadril , Estudos de Coortes , Humanos , Osteólise , Desenho de Prótese
17.
J Biomed Mater Res A ; 65(2): 290-8, 2003 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-12734824

RESUMO

Wear particles generated after total joint arthroplasty activate monocyte/macrophages and incite formation of a granulomatous periprosthetic tissue associated with bone loss and implant loosening. This study tested the hypothesis that selective opsonization of orthopedic implant biomaterial wear particles by human serum proteins influences monocyte/macrophage activation. Serum protein binding to metallic, polymeric, and ceramic particles was determined by one-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). Individual proteins bound to particles were subsequently identified using two-dimensional SDS-PAGE, microsequencing techniques, and SWISS-PROT analysis. Effects of selective protein opsonization on particle-induced monocyte/macrophage activation were assessed by quantification of interleukin-1beta, interleukin-6, and tumor necrosis factor-alpha release. Results from one-dimensional gel analyses revealed distinct serum protein-binding patterns specific for each material tested. Two-dimensional gel analysis together with amino acid sequencing of the prominent protein species confirmed the presence of albumin and alpha-1-antitrypsin bound to all particles tested. In contrast to the metallic particles, apolipoprotein was a major species associated with polymeric particles. Opsonization of PMMA particles with purified preparations of each of the identified proteins showed that albumin significantly enhanced particle-induced monocyte/macrophage activation. These data confirm orthopedic biomaterial specific binding of human serum proteins and demonstrate that albumin exacerbates particle-induced monocyte/macrophage activation. Alterations in the chemical and surface properties of orthopedic biomaterials to modulate protein interactions may improve implant longevity.


Assuntos
Materiais Biocompatíveis/química , Fenômenos Fisiológicos Sanguíneos , Proteínas Sanguíneas/química , Ativação de Macrófagos/fisiologia , Macrófagos/fisiologia , Monócitos/fisiologia , Equipamentos Ortopédicos , Proteínas Sanguíneas/isolamento & purificação , Eletroforese em Gel Bidimensional , Eletroforese em Gel de Poliacrilamida , Humanos , Macrófagos/citologia , Teste de Materiais , Monócitos/citologia , Procedimentos Ortopédicos , Ligação Proteica
18.
Clin Rheumatol ; 32 Suppl 1: S63-5, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23599946

RESUMO

Osteitis pubis is a non-infective inflammation of the symphysis pubis, which is known to be associated with trauma, athletic exertion, urological or gynecological surgery, or with rheumatic conditions such as seronegative spondyloarthropathies. In this report, we describe a case of osteitis pubis whose symptoms were completely ameliorated following tooth extraction attributable to periodontitis. A 57-year-old female patient developed osteitis pubis, presenting with pain in the groin area with an elevated Creactive protein (CRP; 4.4 mg/dl) and radiological erosive changes in symphysis pubis. Prednisolone (5 mg/day) and etodolac were prescribed, but the patient's symptoms improved only partially and remained persistent. One year from the patient's first visit, three teeth were extracted due to severe chronic periodontitis, which she had been suffering from for years. Soon after the above tooth extraction, her symptoms appeared completely resolved, and the patient's CRP was decreased to nearly normal levels in 4 weeks. Human leukocyte antigen (HLA)-typing analysis revealed a positive result for HLA-A11, A24, and B54. Because HLA-B54 cross-reacts with HLA-B27, the patient's osteitis pubis was considered to be a form of reactive arthritis associated with periodontitis.


Assuntos
Osteíte/diagnóstico , Periodontite/patologia , Sínfise Pubiana/patologia , Extração Dentária , Feminino , Humanos , Pessoa de Meia-Idade , Osteíte/etiologia , Osteíte/cirurgia , Periodontite/complicações , Periodontite/cirurgia , Sínfise Pubiana/diagnóstico por imagem , Radiografia , Resultado do Tratamento
19.
J Mech Behav Biomed Mater ; 28: 206-12, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23995342

RESUMO

Highly cross-linked polyethylene (HXPE) in total hip arthroplasty (THA) has been shown to significantly decrease wear rates compared with conventional polyethylene (CPE). However, crosslinking, thermal treatment and oxidation can decrease the mechanical properties of PE, and several cases of fracture of remelted HXPE liners were reported. We present, for the first time, unexpected failures of THA with the use of annealed HXPE liners in two patients occurring at 7 and 8 years after operation. Operative findings revealed dislocated liners from the metal shell and a fracture of the superior rim at the rim-dome junction in both liners. Scanning electron microscopy showed that the cracks initiated at the rim and propagated toward the articular surface. Both liners showed generally a low amount of oxidation (less than 1.00) at the articular surface and low wear rates; however, oxidation at the rim was relatively higher (mean 1.55). These findings suggested that decreased mechanical properties at the rim-dome junction due to cross-linking, annealing and oxidation might have been caused breakage of the HXPE liners after a long implantation time, although the annealed HXPE achieved low degree of wear.


Assuntos
Acetábulo , Artroplastia de Quadril , Fenômenos Mecânicos , Polietileno/química , Falha de Prótese , Acetábulo/diagnóstico por imagem , Feminino , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Oxirredução , Radiografia
20.
J Orthop Res ; 30(12): 2031-7, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22644564

RESUMO

The purpose of this study was to examine the effects of ceramic femoral head material, size, and implantation periods on the wear of annealed, cross-linked ultra-high molecular weight polyethylene (UHMWPE) (XLPE) in total hip arthroplasty compared to non-cross-linked conventional UHMWPE (CPE). XLPE was fabricated by cross-linking with 60 kGy irradiation and annealing. Femoral heads made from zirconia and alumina ceramics and cobalt-chrome (CoCr) of 22 or 26 mm diameter were used. In this retrospective cohort study, the femoral head penetration into the cup was measured digitally on radiographs of 367 hips with XLPE and 64 hips with CPE. The average follow-up periods were 6.3 and 11.9 years, respectively. Both XLPE creep and wear rates were significantly lower than those of CPE (0.19 mm vs. 0.44 mm, 0.0001 mm/year vs. 0.09 mm/year, respectively). Zirconia displayed increased wear rates compared to alumina in CPE; however, there was no difference among head materials in XLPE (0.0008, 0.00007, and -0.009 mm/year for zirconia, alumina, and CoCr, respectively). Neither head size or implantation period impacted XLPE wear. In contrast to CPE, XLPE displayed low wear rates surpassing the effects of varying femoral head material, size, implantation period, and patient demographics. Further follow-up is required to determine the long-term clinical performance of the annealed XLPE.


Assuntos
Artroplastia de Quadril/instrumentação , Reagentes de Ligações Cruzadas/farmacologia , Prótese de Quadril , Polietilenos/química , Idoso , Cerâmica , Reagentes de Ligações Cruzadas/química , Feminino , Cabeça do Fêmur/patologia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise , Falha de Prótese , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA