Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Interv Cardiol ; 29(1): 47-56, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26864951

RESUMO

OBJECTIVES: To assess performance of new, bioresorbable polymer sirolimus-eluting stent (BP-SES), in patients with long coronary lesions (LL) and to compare it to permanent polymer everolimus-eluting stent (PP-EES). BACKGROUND: LL have been associated with worse clinical outcomes in percutaneous coronary interventions (PCI). The impact of lesion length on the outcomes of drug eluting stent (DES) implantations is not as clear. METHODS: In the frame of a randomized, multicentre CENTURY II study, out of 1119 patients enrolled, 182 patients had LL (defined as ≥25 mm), and were assigned randomly to treatment with BP-SES (101) or PP-EES (81). Primary endpoint was target lesion failure (TLF, composite of cardiac death, target vessel related myocardial infarction [MI], and target lesion revascularization [TLR]) at 9 months. All data were 100% monitored and adverse events were adjudicated by an independent clinical event committee. RESULTS: The baseline patient and lesion characteristics were similar in the 2 study arms. At 9-months, the rates of cardiac death (2.0% vs 1.2%; P = 0.70), MI (3.0% vs 4.9%; P = 0.49) and clinically driven TLR (2.0% vs 3.7%; P = 0.48) and TLF (6.9% vs 8.6%; P = 0.67) were similar for BP-SES and PP-EES, respectively. There was no stent thrombosis (ST) in BP-SES group up to 9 months, while 1 case (1.2%) of ST was recorded in PP-EES group (P = 0.44). CONCLUSIONS: Patients with LL showed similar clinical outcomes when treated with Ultimaster BP-SES and Xience PP-EES.


Assuntos
Implantes Absorvíveis , Estenose Coronária , Stents Farmacológicos , Everolimo/farmacologia , Intervenção Coronária Percutânea , Polímeros , Complicações Pós-Operatórias/epidemiologia , Sirolimo/farmacologia , Idoso , Antineoplásicos/farmacologia , Estenose Coronária/diagnóstico , Estenose Coronária/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
2.
Cardiovasc Interv Ther ; 39(1): 47-56, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37642826

RESUMO

The Agent device consists of a semi-compliant balloon catheter, which is coated with a therapeutic low-dose formulation of paclitaxel (2 µg/mm2) blended with an inactive excipient acetyl-tri-n-butyl citrate (ATBC). AGENT Japan SV is a randomized controlled study that enrolled 150 patients from 14 Japanese sites treated with Agent or SeQuent Please paclitaxel-coated balloon. This study also includes a single-arm substudy evaluating the safety and effectiveness of Agent in patients with in-stent restenosis (ISR). Patients with a single de novo native lesion (lesion length ≤ 28 mm and reference diameter ≥ 2.00 to < 3.00 mm) were randomized 2:1 to receive either Agent (n = 101) or SeQuent Please (n = 49). The ISR substudy enrolled 30 patients with lesion length ≤ 28 mm and reference diameter ≥ 2.00 to ≤ 4.00 mm. In the SV RCT, target lesion failure (TLF) at 1 year occurred in four patients treated with Agent (4.0%) versus one patient with SeQuent Please (2.0%; P = 1.00). None of the patients in either treatment arm died. There were no significant differences in the rates of myocardial infarction, target lesion revascularization and target lesion thrombosis through 1 year. In the ISR substudy, the 1-year rates of TLF and target lesion thrombosis were 6.7% and 0.0%, respectively. These data support the safety and effectiveness of the Agent paclitaxel-coated balloon in patients with small vessels and ISR.


Assuntos
Angioplastia Coronária com Balão , Reestenose Coronária , Trombose , Humanos , Paclitaxel/farmacologia , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Resultado do Tratamento , Fatores de Risco , Trombose/etiologia , Materiais Revestidos Biocompatíveis
3.
Catheter Cardiovasc Interv ; 80(5): 789-96, 2012 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-21805606

RESUMO

OBJECTIVES: The aim of this randomized-controlled trial is to compare biolimus A9-eluting stent (Nobori) to sirolimus eluting stent (Cypher). BACKGROUND: The Nobori coronary stent is coated only abluminally with a biodegradable polymer, poly-lactic acid, and the antiproliferative agent biolimus A9. This stent has been studied in randomized trials versus Taxus Express and Taxus Liberte and showed noninferiority and superiority for in-stent late loss. This is the first randomized trial of Nobori stent versus Cypher stent. METHODS: We conducted a randomized (3:2), controlled trial comparing Nobori and Cypher, in 335 patients (198 Nobori and 137 Cypher) at 15 centers in Japan. Patients with de-novo lesions in up to two native coronary arteries were considered for enrollment. The primary endpoint was freedom from target vessel failure (TVF), a composite of cardiac death, myocardial infarction, and target vessel revascularization at 9 months. RESULTS: At 9 months, the primary endpoint of freedom from TVF was 92.6% in Nobori and 93.8% in Cypher arm (noninferiority test P < 0.001). As main secondary endpoints, the in-stent late loss was 0.12 ± 0.30 mm and 0.14 ± 0.34 mm in Nobori and Cypher stents, respectively. Target lesion revascularization was 0.5% in Nobori and 3.9% in Cypher treated patients (P = 0.04). Definite and probable stent thromboses were not recorded in any patient. CONCLUSIONS: Despite the relatively small number of patients, this well controlled clinical trial confirmed the primary hypothesis of non-inferiority of the Nobori biolimus A9-eluting stent to the Cypher sirolimus-eluting stent for freedom from TVF. Both stents showed excellent midterm results.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Estenose Coronária/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Angiografia Coronária , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Trombose Coronária/etiologia , Trombose Coronária/mortalidade , Feminino , Humanos , Japão , Ácido Láctico , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Poliésteres , Polímeros , Desenho de Prótese , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
4.
JACC Cardiovasc Interv ; 13(1): 116-127, 2020 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-31918929

RESUMO

OBJECTIVES: The aim of this study was to investigate the vascular responses and fates of the scaffold after bioresorbable vascular scaffold (BVS) implantation using multimodality imaging. BACKGROUND: Serial comprehensive image assessments after BVS implantation in the context of a randomized trial have not yet been reported. METHODS: In the ABSORB Japan trial, 400 patients were randomized to a BVS (n = 266) or a cobalt-chromium everolimus-eluting stent (n = 134). Through 3 years, patients underwent serial angiography and intravascular ultrasound or optical coherence tomography (OCT). RESULTS: Luminal dimension at 3 years was consistently smaller with the BVS than with the cobalt-chromium everolimus-eluting stent (mean angiographic minimal luminal diameter 2.04 ± 0.63 mm vs. 2.40 ± 0.56 mm, mean difference -0.37 mm [95% confidence interval: -0.50 to -0.24 mm]; p < 0.001), mainly because of smaller device area (6.13 ± 2.03 mm2 vs. 7.15 ± 2.16 mm2, mean difference -1.04 mm2 [95% confidence interval: -1.66 to -0.42 mm2]; p < 0.001), and larger neointimal area (2.10 ± 0.61 mm2 vs. 1.86 ± 0.64 mm2, mean difference 0.24 mm2 [95% confidence interval: 0.06 to 0.43 mm2]; p = 0.01) by OCT. BVS-treated vessels did not show previously reported favorable vessel responses, such as positive vessel remodeling, late luminal enlargement, and restoration of vasomotion, although the OCT-based healing score was on average zero (interquartile range: 0.00 to 0.00). At 3 years, intraluminal scaffold dismantling (ISD) was observed in 14% of BVS. On serial OCT, ISD was observed in 6 lesions at 2 years, where the struts had been fully apposed at post-procedure, while ISD was observed in 12 lesions at 3 years, where 8 lesions were free from ISD on 2-year OCT. In 5 cases of very late scaffold thrombosis, strut discontinuities were detected in all 4 cases with available OCT immediately before reintervention. CONCLUSIONS: In this multimodality serial imaging study, luminal dimension at 3 years was smaller with the BVS than with the cobalt-chromium everolimus-eluting stent. ISD, suspected to be one of the mechanisms of very late BVS thrombosis, was observed in a substantial proportion of cases at 3 years, which developed between post-procedure and 2 years and even beyond 2 years. (AVJ-301 Clinical Trial: A Clinical Evaluation of AVJ-301 [Absorb™ BVS] in Japanese Population [ABSORB JAPAN]; NCT01844284).


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Ligas de Cromo , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Everolimo/administração & dosagem , Imagem Multimodal , Intervenção Coronária Percutânea/instrumentação , Stents , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/etiologia , Everolimo/efeitos adversos , Humanos , Japão , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Método Simples-Cego , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA