Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Hand Surg Am ; 39(6): 1075-81, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24799141

RESUMO

PURPOSE: To evaluate the short-term clinical and radiographic outcome of a silicone proximal interphalangeal (PIP) joint implant using a volar approach in patients with primary osteoarthritis. METHODS: We retrospectively reviewed 36 proximal PIP joints that were replaced with Avanta silicone implants in 26 patients. Inclusion criteria were diagnosis of primary osteoarthrtitis of the PIP joint and failure to respond to conservative treatment. Clinical asessment included range of motion, patient satisfaction, and pain scores. The Quick-Disabilities of the Arm, Shoulder, and Hand questionnaire was administered at final follow-up. Radiographs were reviewed for alignment and implant fracture. Complications were also recorded. RESULTS: After an average follow-up of 18 months (range, 12-60 mo), pain relief was markedly reduced in all patients, decreasing from a mean score of 7.2 preoperatively to 0.4 postoperatively. The arc of active motion of the PIP joint improved from 33° to 72°. Satisfaction averaged 4.8 on a 5-point Likert scale, and all patients stated they would repeat the surgery. The median final average Quick-Disabilities of the Arm, Shoulder, and Hand score was 7 (range, 4-12). Radiograph review showed 2 implant fractures at 1 and 2 years after surgery, respectively, but without clinical changes. The average deformity in the coronal plane changed from 12° (range, 8° to 18°) preoperatively to 4° (range, 3° to 8°) postoperatively, whereas the average flexion contracture changed from 18° (range, 10° to 30°) to 0° (all patients achieved full active extension). No other complications were observed. No revision surgery has been needed to date. CONCLUSIONS: The volar approach to PIP joint silicone arthroplasty offers the advantages of maintaining the integrity of the extensor mechanism, providing pain relief, and improving postoperative range of motion with minimal complications. However, further research is needed to determine the long-term efficacy of this implant. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.


Assuntos
Artroplastia de Substituição de Dedo/métodos , Prótese Articular , Osteoartrite/cirurgia , Adulto , Idoso , Avaliação da Deficiência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/diagnóstico por imagem , Medição da Dor , Satisfação do Paciente , Desenho de Prótese , Radiografia , Amplitude de Movimento Articular , Estudos Retrospectivos , Silicones , Resultado do Tratamento
2.
Hip Int ; 27(2): 153-161, 2017 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-28165590

RESUMO

BACKGROUND: It is believed that the path of acetabular screws may represent a shuttle between hydroxyapatite (HA) particles and the liner. The aim was to assess the relationship between acetabular screws and revision surgery for aseptic loosening in total hip arthroplasties (THAs). MATERIAL AND METHODS: A retrospective multicentric study was performed. Patients older than 18 years and patients who underwent THA with both the stem and cup HA-coated were included. The rate of revision-surgery considering only aseptic loosening was calculated. The proportion of cases in which acetabular screws were used was registered, as well as the proportion of cups that showed osteolysis. The statistical relationship between acetabular screws and osteolysis, as well as acetabular screws and revision-surgery for aseptic loosening were assessed. RESULTS: There were 749 cases. Mean age 62.1 (45-84) years. Mean follow-up 14.19 (8.9-16.7) years. Revision surgery was performed in 12.8% (96/749) of the cups. 73.95% (71/96) of the revised cups showed aseptic loosening. The overall 15-year survival of the cups considering only aseptic loosening was 84.4%. Acetabular screws were used in 47.5% (356/749) of the cups. Acetabular screws were used in 40.44% (55/136) of the cups that showed osteolysis. The use of acetabular screws was associated with less osteolysis (p = 0.006). Acetabular screws were used in 35.21% (25/71) of the cups that were revised for aseptic loosening. The use of acetabular screws was associated with a lower rate of revision surgery (p = 0.020). CONCLUSIONS: In THA with the stem and cup HA-coated, the use of acetabular screws is associated with a lower rate of revision surgery.


Assuntos
Artroplastia de Quadril/métodos , Parafusos Ósseos , Durapatita/química , Osteoartrite do Quadril/cirurgia , Desenho de Prótese , Falha de Prótese/tendências , Acetábulo/cirurgia , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Materiais Revestidos Biocompatíveis , Estudos de Coortes , Feminino , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Reoperação/métodos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA