1.
Polim Med ; 53(1): 19-24, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36929643

RESUMO

BACKGROUND: Occlusal splints can protect teeth during bruxism, preventing tooth wear, as well as during sports activities, shielding them from impacts. OBJECTIVES: To verify the influence of thermal cycles and disinfection on the roughness, microhardness and color of polyethylene terephthalate glycol/thermoplastic polyurethane (PETG/TPU) and poly(methyl methacrylate) (PMMA). MATERIAL AND METHODS: Thirty-six PETG/TPU samples and 36 PMMA samples were prepared (ø10 mm × 3 mm). Six groups were created according to the material and the disinfection method used (n = 12 each): PETG/TPU (glister), PETG/TPU (hypochlorite), PETG/TPU (soap), PMMA (glister), PMMA (hypochlorite), and PMMA (soap). Roughness, Knoop microhardness and color evaluations were performed before the experiments (T1), after thermocycling (T2) and after disinfection (T3). Three-way repeated measures analysis of variance (ANOVA) and Tukey's test were used for statistical evaluations. RESULTS: For roughness and color, ANOVA showed statistical significance based on the interaction between thermal cycling, material and disinfectant factors. In terms of Knoop microhardness, ANOVA showed statistical significance based on the interaction between thermal cycling and material factors. CONCLUSIONS: Roughness results were clinically acceptable in all groups at all time points, except the PETG/TPU and PMMA groups disinfected with hypochlorite. Microhardness significantly increased for both materials after thermal cycling, and at all time points, the microhardness of PMMA was significantly higher than that of PETG/TPU. After thermal cycling, the color changes were clinically unacceptable in all groups.


Assuntos
Desinfecção , Polimetil Metacrilato , Desinfecção/métodos , Ácido Hipocloroso , Teste de Materiais , Sabões , Propriedades de Superfície
2.
Polim Med ; 52(2): 93-99, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36504451

RESUMO

BACKGROUND: Temporary prosthesis protects the oral tissues, in addition to providing aesthetic look and masticatory function until a definitive prosthesis is manufactured. OBJECTIVES: To evaluate the effect of glaze and 0.12% chlorhexidine (CHX) on the physical and mechanical properties of bis-acryl, and to evaluate the antimicrobial efficacy of CHX. MATERIAL AND METHODS: Eighty specimens of bis-acryl resin were made. Over 40 of them the glaze was applied. One specimen with and 1 specimen without glaze were placed in niches of an appliance manufactured for each patient. Each of the 20 volunteers received 2 devices. Initially, the volunteers used one device and treated it with sucrose for 7 days (control), and later they used the other device and treated it with sucrose and CHX for 7 days (test). Color, microhardness, roughness, surface energy, and insoluble extracellular polysaccharides (EPS) tests were performed. All results were submitted to the Tukey's test, with the exception of the EPS results, which were submitted to the Student's t test. RESULTS: The ΔE00 of the unglazed control group was significantly higher than that of the unglazed test group. In all groups, a significant decrease in microhardness occurred over time. At both times, the glaze significantly increased the microhardness of the specimens (in all the glazed groups). At the final time, the test glaze group showed significantly higher microhardness compared with the control glaze group. Roughness in the groups without glaze increased significantly with CHX treatment over time. At both times, the glaze generated a significant reduction in roughness in the control and test groups. There was a significant reduction in surface energy over time in all groups. In most comparisons, the glazed groups showed significantly higher surface energy values compared with the unglazed control group. At the final time point, the unglazed test group showed a significantly higher surface energy value than the unglazed control group; and the glazed test group showed a significantly higher surface energy value compared with the glazed control group. The resins that received CHX had a significantly lower amount of biofilm. CONCLUSIONS: Color values were clinically acceptable in all tested groups. At both time points, the roughness values were clinically acceptable only in the glazed groups. Glaze increased the microhardness of the specimens. Microhardness and surface energy were reduced over time in all groups. Chlorhexidine can help prevent microhardness degradation. Glaze and CHX can increase surface energy. Chlorhexidine reduced the amount of bacterial biofilm.


Assuntos
Resinas Acrílicas , Clorexidina , Humanos , Clorexidina/farmacologia , Próteses e Implantes , Biofilmes , Propriedades de Superfície , Teste de Materiais
3.
RSBO (Impr.) ; 12(3): 239-245, Jul.-Sep. 2015. ilus
Artigo em Inglês | LILACS | ID: biblio-842384

RESUMO

Introduction: The rehabilitation with implant-supported fixed prosthesis is an effective therapy for the treatment of edentulous patients, especially for mandibles, following Brånemark protocol. Case report:A male patient, aged 62 years, fully edentulous, already had 05 implants, between mental foramen. The rehabilitative therapy employed used both maxillary total denture upper associated with mandibular implant-supported denture following Brånemark protocol. Conclusion: The implant-supported denture following Brånemark protocol is a viable alternative, providing stability to the denture, masticatory efficiency, and aesthetics. Each case should be carefully analyzed and planned to reach a successful treatment.